ºÝºÝߣshows by User: ClaudioLiciotti / http://www.slideshare.net/images/logo.gif ºÝºÝߣshows by User: ClaudioLiciotti / Sat, 12 Nov 2022 15:43:26 GMT ºÝºÝߣShare feed for ºÝºÝߣshows by User: ClaudioLiciotti Revamping e repowering di impianti FV: accortezze normative /slideshow/revamping-e-repowering-di-impianti-fv-accortezze-normative/254152114 20221014presentazioneliciotti-221112154326-034c2761
Repowering degli impianti fotovoltaici utility-scale: tecnologie, normative, certificazioni zeroEmission MEDITERRANEAN 2022 ROOM B - Hermann Scheer - Venerdì 14 Ottobre 11:15 - 13:00 ]]>

Repowering degli impianti fotovoltaici utility-scale: tecnologie, normative, certificazioni zeroEmission MEDITERRANEAN 2022 ROOM B - Hermann Scheer - Venerdì 14 Ottobre 11:15 - 13:00 ]]>
Sat, 12 Nov 2022 15:43:26 GMT /slideshow/revamping-e-repowering-di-impianti-fv-accortezze-normative/254152114 ClaudioLiciotti@slideshare.net(ClaudioLiciotti) Revamping e repowering di impianti FV: accortezze normative ClaudioLiciotti Repowering degli impianti fotovoltaici utility-scale: tecnologie, normative, certificazioni zeroEmission MEDITERRANEAN 2022 ROOM B - Hermann Scheer - Venerdì 14 Ottobre 11:15 - 13:00 <img style="border:1px solid #C3E6D8;float:right;" alt="" src="https://cdn.slidesharecdn.com/ss_thumbnails/20221014presentazioneliciotti-221112154326-034c2761-thumbnail.jpg?width=120&amp;height=120&amp;fit=bounds" /><br> Repowering degli impianti fotovoltaici utility-scale: tecnologie, normative, certificazioni zeroEmission MEDITERRANEAN 2022 ROOM B - Hermann Scheer - Venerdì 14 Ottobre 11:15 - 13:00
Revamping e repowering di impianti FV: accortezze normative from Claudio Liciotti
]]>
31 0 https://cdn.slidesharecdn.com/ss_thumbnails/20221014presentazioneliciotti-221112154326-034c2761-thumbnail.jpg?width=120&height=120&fit=bounds presentation Black http://activitystrea.ms/schema/1.0/post http://activitystrea.ms/schema/1.0/posted 0
Le verifiche (CEI EN IEC 62446-2 ) e la qualità degli Impianti FV /slideshow/le-verifiche-cei-en-iec-624462-e-la-qualit-degli-impianti-fv/249984157 sess-210815142524
A Novembre 2020 è stata pubblicata la CEI EN IEC 62446-2 in Inglese A Marzo 2021 è stata pubblicata la CEI EN IEC 62446-2 in italiano Questa norma contiene al suo interno delle indicazioni relative a verifiche e procedure di prova sugli impianti FV: a tal proposito richiama completamente alla CEI EN IEC 62446-1. ]]>

A Novembre 2020 è stata pubblicata la CEI EN IEC 62446-2 in Inglese A Marzo 2021 è stata pubblicata la CEI EN IEC 62446-2 in italiano Questa norma contiene al suo interno delle indicazioni relative a verifiche e procedure di prova sugli impianti FV: a tal proposito richiama completamente alla CEI EN IEC 62446-1. ]]>
Sun, 15 Aug 2021 14:25:24 GMT /slideshow/le-verifiche-cei-en-iec-624462-e-la-qualit-degli-impianti-fv/249984157 ClaudioLiciotti@slideshare.net(ClaudioLiciotti) Le verifiche (CEI EN IEC 62446-2 ) e la qualità degli Impianti FV ClaudioLiciotti A Novembre 2020 è stata pubblicata la CEI EN IEC 62446-2 in Inglese A Marzo 2021 è stata pubblicata la CEI EN IEC 62446-2 in italiano Questa norma contiene al suo interno delle indicazioni relative a verifiche e procedure di prova sugli impianti FV: a tal proposito richiama completamente alla CEI EN IEC 62446-1. <img style="border:1px solid #C3E6D8;float:right;" alt="" src="https://cdn.slidesharecdn.com/ss_thumbnails/sess-210815142524-thumbnail.jpg?width=120&amp;height=120&amp;fit=bounds" /><br> A Novembre 2020 è stata pubblicata la CEI EN IEC 62446-2 in Inglese A Marzo 2021 è stata pubblicata la CEI EN IEC 62446-2 in italiano Questa norma contiene al suo interno delle indicazioni relative a verifiche e procedure di prova sugli impianti FV: a tal proposito richiama completamente alla CEI EN IEC 62446-1.
Le verifiche (CEI EN IEC 62446-2 ) e la qualità degli Impianti FV from Claudio Liciotti
]]>
836 0 https://cdn.slidesharecdn.com/ss_thumbnails/sess-210815142524-thumbnail.jpg?width=120&height=120&fit=bounds presentation Black http://activitystrea.ms/schema/1.0/post http://activitystrea.ms/schema/1.0/posted 0
L’applicazione delle norme e i periodi transitori /slideshow/lapplicazione-delle-norme-e-i-periodi-transitori/239370867 20200508presentazioneliciotti-rev01-201121155002
Le norme e altre pubblicazioni in materia di normazione sono orientamenti volontari che forniscono specifiche tecniche per prodotti, servizi e processi. Sebbene le norme in quanto tali siano volontarie (non obbligatorie), la loro applicazione garantisce il rispetto della regola d’arte, e quindi della legge. ]]>

Le norme e altre pubblicazioni in materia di normazione sono orientamenti volontari che forniscono specifiche tecniche per prodotti, servizi e processi. Sebbene le norme in quanto tali siano volontarie (non obbligatorie), la loro applicazione garantisce il rispetto della regola d’arte, e quindi della legge. ]]>
Sat, 21 Nov 2020 15:50:01 GMT /slideshow/lapplicazione-delle-norme-e-i-periodi-transitori/239370867 ClaudioLiciotti@slideshare.net(ClaudioLiciotti) L’applicazione delle norme e i periodi transitori ClaudioLiciotti Le norme e altre pubblicazioni in materia di normazione sono orientamenti volontari che forniscono specifiche tecniche per prodotti, servizi e processi. Sebbene le norme in quanto tali siano volontarie (non obbligatorie), la loro applicazione garantisce il rispetto della regola d’arte, e quindi della legge. <img style="border:1px solid #C3E6D8;float:right;" alt="" src="https://cdn.slidesharecdn.com/ss_thumbnails/20200508presentazioneliciotti-rev01-201121155002-thumbnail.jpg?width=120&amp;height=120&amp;fit=bounds" /><br> Le norme e altre pubblicazioni in materia di normazione sono orientamenti volontari che forniscono specifiche tecniche per prodotti, servizi e processi. Sebbene le norme in quanto tali siano volontarie (non obbligatorie), la loro applicazione garantisce il rispetto della regola d’arte, e quindi della legge.
L’applicazione delle norme e i periodi transitori from Claudio Liciotti
]]>
35 0 https://cdn.slidesharecdn.com/ss_thumbnails/20200508presentazioneliciotti-rev01-201121155002-thumbnail.jpg?width=120&height=120&fit=bounds presentation Black http://activitystrea.ms/schema/1.0/post http://activitystrea.ms/schema/1.0/posted 0
Norme armonizzate, marcatura CE, volontarietà delle norme e periodi di sovrapposizione normativa /ClaudioLiciotti/norme-armonizzate-marcatura-ce-volontariet-delle-norme-e-periodi-di-sovrapposizione-normativa 0420180702liciottirev-201121154846
Quando una «nuova norma» sta per sostituire una «vecchia norma» c’è un tempo nel quale le 2 norme coesistono per consentire una transizione progressiva. Il periodo di sovrapposizione si applica sia alle norme armonizzate che alle norme non armonizzate. ]]>

Quando una «nuova norma» sta per sostituire una «vecchia norma» c’è un tempo nel quale le 2 norme coesistono per consentire una transizione progressiva. Il periodo di sovrapposizione si applica sia alle norme armonizzate che alle norme non armonizzate. ]]>
Sat, 21 Nov 2020 15:48:46 GMT /ClaudioLiciotti/norme-armonizzate-marcatura-ce-volontariet-delle-norme-e-periodi-di-sovrapposizione-normativa ClaudioLiciotti@slideshare.net(ClaudioLiciotti) Norme armonizzate, marcatura CE, volontarietà delle norme e periodi di sovrapposizione normativa ClaudioLiciotti Quando una «nuova norma» sta per sostituire una «vecchia norma» c’è un tempo nel quale le 2 norme coesistono per consentire una transizione progressiva. Il periodo di sovrapposizione si applica sia alle norme armonizzate che alle norme non armonizzate. <img style="border:1px solid #C3E6D8;float:right;" alt="" src="https://cdn.slidesharecdn.com/ss_thumbnails/0420180702liciottirev-201121154846-thumbnail.jpg?width=120&amp;height=120&amp;fit=bounds" /><br> Quando una «nuova norma» sta per sostituire una «vecchia norma» c’è un tempo nel quale le 2 norme coesistono per consentire una transizione progressiva. Il periodo di sovrapposizione si applica sia alle norme armonizzate che alle norme non armonizzate.
Norme armonizzate, marcatura CE, volontarietà delle norme e periodi di sovrapposizione normativa from Claudio Liciotti
]]>
110 0 https://cdn.slidesharecdn.com/ss_thumbnails/0420180702liciottirev-201121154846-thumbnail.jpg?width=120&height=120&fit=bounds presentation Black http://activitystrea.ms/schema/1.0/post http://activitystrea.ms/schema/1.0/posted 0
La Manutenzione degli impianti Fotovoltaici /slideshow/la-manutenzione-degli-impianti-fotovoltaici/239370821 20190323elettromondo-201121154214
«La manutenzione ha lo scopo di conservare le condizioni di sicurezza e di funzionalità dell’impianto elettrico nel tempo.» (fonte Guida CEI-010) «La necessità di svolgere la manutenzione deriva…..da obblighi legislativi attribuiti a soggetti espressamente individuati;» (fonte Guida CEI-010) «La necessità di svolgere la manutenzione deriva …….dall’esigenza di evitare le conseguenze economiche e sociali causate dall’impossibilità di utilizzare un impianto non sicuro o non funzionale, anche temporaneamente. «(fonte Guida CEI-010)]]>

«La manutenzione ha lo scopo di conservare le condizioni di sicurezza e di funzionalità dell’impianto elettrico nel tempo.» (fonte Guida CEI-010) «La necessità di svolgere la manutenzione deriva…..da obblighi legislativi attribuiti a soggetti espressamente individuati;» (fonte Guida CEI-010) «La necessità di svolgere la manutenzione deriva …….dall’esigenza di evitare le conseguenze economiche e sociali causate dall’impossibilità di utilizzare un impianto non sicuro o non funzionale, anche temporaneamente. «(fonte Guida CEI-010)]]>
Sat, 21 Nov 2020 15:42:14 GMT /slideshow/la-manutenzione-degli-impianti-fotovoltaici/239370821 ClaudioLiciotti@slideshare.net(ClaudioLiciotti) La Manutenzione degli impianti Fotovoltaici ClaudioLiciotti «La manutenzione ha lo scopo di conservare le condizioni di sicurezza e di funzionalità dell’impianto elettrico nel tempo.» (fonte Guida CEI-010) «La necessità di svolgere la manutenzione deriva…..da obblighi legislativi attribuiti a soggetti espressamente individuati;» (fonte Guida CEI-010) «La necessità di svolgere la manutenzione deriva …….dall’esigenza di evitare le conseguenze economiche e sociali causate dall’impossibilità di utilizzare un impianto non sicuro o non funzionale, anche temporaneamente. «(fonte Guida CEI-010) <img style="border:1px solid #C3E6D8;float:right;" alt="" src="https://cdn.slidesharecdn.com/ss_thumbnails/20190323elettromondo-201121154214-thumbnail.jpg?width=120&amp;height=120&amp;fit=bounds" /><br> «La manutenzione ha lo scopo di conservare le condizioni di sicurezza e di funzionalità dell’impianto elettrico nel tempo.» (fonte Guida CEI-010) «La necessità di svolgere la manutenzione deriva…..da obblighi legislativi attribuiti a soggetti espressamente individuati;» (fonte Guida CEI-010) «La necessità di svolgere la manutenzione deriva …….dall’esigenza di evitare le conseguenze economiche e sociali causate dall’impossibilità di utilizzare un impianto non sicuro o non funzionale, anche temporaneamente. «(fonte Guida CEI-010)
La Manutenzione degli impianti Fotovoltaici from Claudio Liciotti
]]>
446 0 https://cdn.slidesharecdn.com/ss_thumbnails/20190323elettromondo-201121154214-thumbnail.jpg?width=120&height=120&fit=bounds presentation Black http://activitystrea.ms/schema/1.0/post http://activitystrea.ms/schema/1.0/posted 0
Nuovi riferimenti normativi per testing e valutazione di conformità di moduli fotovoltaici /slideshow/nuovi-riferimenti-normativi-per-testing-e-valutazione-di-conformit-di-moduli-fotovoltaici/102204697 mi02072018-180612211910
La crescita del mercato e dell’industria fotovoltaica ha fatto sì che gli operatori del settore abbiano sempre più puntato l’attenzione sull’affidabilità dei prodotti e sulla differenziazione degli stessi. La qualità e l’affidabilità dei moduli fotovoltaici può essere valutata mediante testing in accordo alle specifiche norme di prodotto: la Norma CEI EN 61215 (serie) e la Norma CEI EN 61730 (Parte 1 e Parte 2) che, nel loro recente aggiornamento, hanno introdotto rilevanti novità. Nel corso del seminario, gli aspetti relativi alle prove e alle certificazioni dei moduli secondo tali norme saranno discussi fra gli Officer del CT 82 del CEI e gli operatori del mercato dei moduli FV, tenendo conto che, mentre l’applicazione della Norma CEI EN 61215 ha carattere di volontarietà per dimostrare la qualità del prodotto, la rispondenza alla Norma CEI EN 61730 (essendo norma europea armonizzata ai sensi della Direttiva Bassa Tensione, per le prescrizioni di sicurezza) è un requisito sufficiente a garantire la presunzione di conformità alla Direttiva BT, giacché il “prodotto†modulo fotovoltaico, per essere immesso sul mercato comunitario, deve essere dotato di marcatura CE.]]>

La crescita del mercato e dell’industria fotovoltaica ha fatto sì che gli operatori del settore abbiano sempre più puntato l’attenzione sull’affidabilità dei prodotti e sulla differenziazione degli stessi. La qualità e l’affidabilità dei moduli fotovoltaici può essere valutata mediante testing in accordo alle specifiche norme di prodotto: la Norma CEI EN 61215 (serie) e la Norma CEI EN 61730 (Parte 1 e Parte 2) che, nel loro recente aggiornamento, hanno introdotto rilevanti novità. Nel corso del seminario, gli aspetti relativi alle prove e alle certificazioni dei moduli secondo tali norme saranno discussi fra gli Officer del CT 82 del CEI e gli operatori del mercato dei moduli FV, tenendo conto che, mentre l’applicazione della Norma CEI EN 61215 ha carattere di volontarietà per dimostrare la qualità del prodotto, la rispondenza alla Norma CEI EN 61730 (essendo norma europea armonizzata ai sensi della Direttiva Bassa Tensione, per le prescrizioni di sicurezza) è un requisito sufficiente a garantire la presunzione di conformità alla Direttiva BT, giacché il “prodotto†modulo fotovoltaico, per essere immesso sul mercato comunitario, deve essere dotato di marcatura CE.]]>
Tue, 12 Jun 2018 21:19:10 GMT /slideshow/nuovi-riferimenti-normativi-per-testing-e-valutazione-di-conformit-di-moduli-fotovoltaici/102204697 ClaudioLiciotti@slideshare.net(ClaudioLiciotti) Nuovi riferimenti normativi per testing e valutazione di conformità di moduli fotovoltaici ClaudioLiciotti La crescita del mercato e dell’industria fotovoltaica ha fatto sì che gli operatori del settore abbiano sempre più puntato l’attenzione sull’affidabilità dei prodotti e sulla differenziazione degli stessi. La qualità e l’affidabilità dei moduli fotovoltaici può essere valutata mediante testing in accordo alle specifiche norme di prodotto: la Norma CEI EN 61215 (serie) e la Norma CEI EN 61730 (Parte 1 e Parte 2) che, nel loro recente aggiornamento, hanno introdotto rilevanti novità. Nel corso del seminario, gli aspetti relativi alle prove e alle certificazioni dei moduli secondo tali norme saranno discussi fra gli Officer del CT 82 del CEI e gli operatori del mercato dei moduli FV, tenendo conto che, mentre l’applicazione della Norma CEI EN 61215 ha carattere di volontarietà per dimostrare la qualità del prodotto, la rispondenza alla Norma CEI EN 61730 (essendo norma europea armonizzata ai sensi della Direttiva Bassa Tensione, per le prescrizioni di sicurezza) è un requisito sufficiente a garantire la presunzione di conformità alla Direttiva BT, giacché il “prodotto†modulo fotovoltaico, per essere immesso sul mercato comunitario, deve essere dotato di marcatura CE. <img style="border:1px solid #C3E6D8;float:right;" alt="" src="https://cdn.slidesharecdn.com/ss_thumbnails/mi02072018-180612211910-thumbnail.jpg?width=120&amp;height=120&amp;fit=bounds" /><br> La crescita del mercato e dell’industria fotovoltaica ha fatto sì che gli operatori del settore abbiano sempre più puntato l’attenzione sull’affidabilità dei prodotti e sulla differenziazione degli stessi. La qualità e l’affidabilità dei moduli fotovoltaici può essere valutata mediante testing in accordo alle specifiche norme di prodotto: la Norma CEI EN 61215 (serie) e la Norma CEI EN 61730 (Parte 1 e Parte 2) che, nel loro recente aggiornamento, hanno introdotto rilevanti novità. Nel corso del seminario, gli aspetti relativi alle prove e alle certificazioni dei moduli secondo tali norme saranno discussi fra gli Officer del CT 82 del CEI e gli operatori del mercato dei moduli FV, tenendo conto che, mentre l’applicazione della Norma CEI EN 61215 ha carattere di volontarietà per dimostrare la qualità del prodotto, la rispondenza alla Norma CEI EN 61730 (essendo norma europea armonizzata ai sensi della Direttiva Bassa Tensione, per le prescrizioni di sicurezza) è un requisito sufficiente a garantire la presunzione di conformità alla Direttiva BT, giacché il “prodotto†modulo fotovoltaico, per essere immesso sul mercato comunitario, deve essere dotato di marcatura CE.
Nuovi riferimenti normativi per testing e valutazione di conformità di moduli fotovoltaici from Claudio Liciotti
]]>
68 2 https://cdn.slidesharecdn.com/ss_thumbnails/mi02072018-180612211910-thumbnail.jpg?width=120&height=120&fit=bounds document Black http://activitystrea.ms/schema/1.0/post http://activitystrea.ms/schema/1.0/posted 0
L’importanza della Manutenzione negli impianti FV /slideshow/limportanza-della-manutenzione-negli-impianti-fv-55559685/55559685 20151015ordineingbolzano-copia2-151126212121-lva1-app6892
ORDINE INGEGNERI BOLZANO - INGENIEURKAMMER BOZEN Evento formativo di aggiornamento di Prevenzione Incendi di cui al DM 5 agosto 2011 - “Rischio incendio: il fotovoltaico sicuro†]]>

ORDINE INGEGNERI BOLZANO - INGENIEURKAMMER BOZEN Evento formativo di aggiornamento di Prevenzione Incendi di cui al DM 5 agosto 2011 - “Rischio incendio: il fotovoltaico sicuro†]]>
Thu, 26 Nov 2015 21:21:21 GMT /slideshow/limportanza-della-manutenzione-negli-impianti-fv-55559685/55559685 ClaudioLiciotti@slideshare.net(ClaudioLiciotti) L’importanza della Manutenzione negli impianti FV ClaudioLiciotti ORDINE INGEGNERI BOLZANO - INGENIEURKAMMER BOZEN Evento formativo di aggiornamento di Prevenzione Incendi di cui al DM 5 agosto 2011 - “Rischio incendio: il fotovoltaico sicuro†<img style="border:1px solid #C3E6D8;float:right;" alt="" src="https://cdn.slidesharecdn.com/ss_thumbnails/20151015ordineingbolzano-copia2-151126212121-lva1-app6892-thumbnail.jpg?width=120&amp;height=120&amp;fit=bounds" /><br> ORDINE INGEGNERI BOLZANO - INGENIEURKAMMER BOZEN Evento formativo di aggiornamento di Prevenzione Incendi di cui al DM 5 agosto 2011 - “Rischio incendio: il fotovoltaico sicuroâ€
L’importanza della Manutenzione negli impianti FV from Claudio Liciotti
]]>
835 7 https://cdn.slidesharecdn.com/ss_thumbnails/20151015ordineingbolzano-copia2-151126212121-lva1-app6892-thumbnail.jpg?width=120&height=120&fit=bounds presentation 000000 http://activitystrea.ms/schema/1.0/post http://activitystrea.ms/schema/1.0/posted 0
R OUND-ROBIN VERIFICATION AND FINAL DEVELOPMENT OF THE IEC 62788-1-5 ENCAPSULATION SIZE CHANGE TEST /slideshow/r-oundrobin-verification-and-final-development-of-the-iec-6278815-encapsulation-size-change-test/55559588 2015pvmrw18miller-151126211436-lva1-app6891
Polymeric encapsulation materials may a change size when processed at typical module lamination temperatures. The relief of residual strain, trapped during the manufacture of encapsulation sheet, can affect module performance and reliability. For example, displaced cells and interconnects threaten: cell fracture; broken interconnects (open circuits and ground faults); delamination at interfaces; and void formation. The IEC 62788-1-5 standard quantifies the maximum change in linear dimensions that may occur to allow for process control of size change. Developments incorporated into the Committee Draft (CD) of the standard as well as the assessment of the repeatability and reproducibility of the test method are described here. No pass/fail criteria are given in the standard, rather a repeatable protocol to quantify the change in dimension is provided to aid those working with encapsulation.]]>

Polymeric encapsulation materials may a change size when processed at typical module lamination temperatures. The relief of residual strain, trapped during the manufacture of encapsulation sheet, can affect module performance and reliability. For example, displaced cells and interconnects threaten: cell fracture; broken interconnects (open circuits and ground faults); delamination at interfaces; and void formation. The IEC 62788-1-5 standard quantifies the maximum change in linear dimensions that may occur to allow for process control of size change. Developments incorporated into the Committee Draft (CD) of the standard as well as the assessment of the repeatability and reproducibility of the test method are described here. No pass/fail criteria are given in the standard, rather a repeatable protocol to quantify the change in dimension is provided to aid those working with encapsulation.]]>
Thu, 26 Nov 2015 21:14:36 GMT /slideshow/r-oundrobin-verification-and-final-development-of-the-iec-6278815-encapsulation-size-change-test/55559588 ClaudioLiciotti@slideshare.net(ClaudioLiciotti) R OUND-ROBIN VERIFICATION AND FINAL DEVELOPMENT OF THE IEC 62788-1-5 ENCAPSULATION SIZE CHANGE TEST ClaudioLiciotti Polymeric encapsulation materials may a change size when processed at typical module lamination temperatures. The relief of residual strain, trapped during the manufacture of encapsulation sheet, can affect module performance and reliability. For example, displaced cells and interconnects threaten: cell fracture; broken interconnects (open circuits and ground faults); delamination at interfaces; and void formation. The IEC 62788-1-5 standard quantifies the maximum change in linear dimensions that may occur to allow for process control of size change. Developments incorporated into the Committee Draft (CD) of the standard as well as the assessment of the repeatability and reproducibility of the test method are described here. No pass/fail criteria are given in the standard, rather a repeatable protocol to quantify the change in dimension is provided to aid those working with encapsulation. <img style="border:1px solid #C3E6D8;float:right;" alt="" src="https://cdn.slidesharecdn.com/ss_thumbnails/2015pvmrw18miller-151126211436-lva1-app6891-thumbnail.jpg?width=120&amp;height=120&amp;fit=bounds" /><br> Polymeric encapsulation materials may a change size when processed at typical module lamination temperatures. The relief of residual strain, trapped during the manufacture of encapsulation sheet, can affect module performance and reliability. For example, displaced cells and interconnects threaten: cell fracture; broken interconnects (open circuits and ground faults); delamination at interfaces; and void formation. The IEC 62788-1-5 standard quantifies the maximum change in linear dimensions that may occur to allow for process control of size change. Developments incorporated into the Committee Draft (CD) of the standard as well as the assessment of the repeatability and reproducibility of the test method are described here. No pass/fail criteria are given in the standard, rather a repeatable protocol to quantify the change in dimension is provided to aid those working with encapsulation.
R OUND-ROBIN VERIFICATION AND FINAL DEVELOPMENT OF THE IEC 62788-1-5 ENCAPSULATION SIZE CHANGE TEST from Claudio Liciotti
]]>
190 5 https://cdn.slidesharecdn.com/ss_thumbnails/2015pvmrw18miller-151126211436-lva1-app6891-thumbnail.jpg?width=120&height=120&fit=bounds document Black http://activitystrea.ms/schema/1.0/post http://activitystrea.ms/schema/1.0/posted 0
Analisi del degrado delle caratteristiche dei moduli affetti dai fenomeni ‘PID - potential induced degradation’ e ‘bave di lumaca’: progress report di prove sperimentali /slideshow/analisi-del-degrado-delle-caratteristiche-dei-moduli-affetti-dai-fenomeni-pid-potential-induced-degradation-e-bave-di-lumaca-progress-report-di-prove-sperimentali-46953892/46953892 bertani-150413162548-conversion-gate01
DARIO BERTANI, RSE - CLAUDIO LICIOTTI]]>

DARIO BERTANI, RSE - CLAUDIO LICIOTTI]]>
Mon, 13 Apr 2015 16:25:48 GMT /slideshow/analisi-del-degrado-delle-caratteristiche-dei-moduli-affetti-dai-fenomeni-pid-potential-induced-degradation-e-bave-di-lumaca-progress-report-di-prove-sperimentali-46953892/46953892 ClaudioLiciotti@slideshare.net(ClaudioLiciotti) Analisi del degrado delle caratteristiche dei moduli affetti dai fenomeni ‘PID - potential induced degradation’ e ‘bave di lumaca’: progress report di prove sperimentali ClaudioLiciotti DARIO BERTANI, RSE - CLAUDIO LICIOTTI <img style="border:1px solid #C3E6D8;float:right;" alt="" src="https://cdn.slidesharecdn.com/ss_thumbnails/bertani-150413162548-conversion-gate01-thumbnail.jpg?width=120&amp;height=120&amp;fit=bounds" /><br> DARIO BERTANI, RSE - CLAUDIO LICIOTTI
Analisi del degrado delle caratteristiche dei moduli affetti dai fenomeni ‘PID - potential induced degradation’ e ‘bave di lumaca’: progress report di prove sperimentali from Claudio Liciotti
]]>
708 24 https://cdn.slidesharecdn.com/ss_thumbnails/bertani-150413162548-conversion-gate01-thumbnail.jpg?width=120&height=120&fit=bounds document Black http://activitystrea.ms/schema/1.0/post http://activitystrea.ms/schema/1.0/posted 0
A modular apparatus for architectural integration of frameless solar modules /slideshow/a-modular-apparatus-for-architectural-integration-of-frameless-solar-modules/40979073 ep2642218a1-141031160910-conversion-gate02
Application number: EP20120179408 20120806 The present invention relates to an apparatus composed of three modular metal sections (1,2,3) for architectural integration of frameless laminate solar modules (M) on the inclined pitches of building roofs.]]>

Application number: EP20120179408 20120806 The present invention relates to an apparatus composed of three modular metal sections (1,2,3) for architectural integration of frameless laminate solar modules (M) on the inclined pitches of building roofs.]]>
Fri, 31 Oct 2014 16:09:10 GMT /slideshow/a-modular-apparatus-for-architectural-integration-of-frameless-solar-modules/40979073 ClaudioLiciotti@slideshare.net(ClaudioLiciotti) A modular apparatus for architectural integration of frameless solar modules ClaudioLiciotti Application number: EP20120179408 20120806 The present invention relates to an apparatus composed of three modular metal sections (1,2,3) for architectural integration of frameless laminate solar modules (M) on the inclined pitches of building roofs. <img style="border:1px solid #C3E6D8;float:right;" alt="" src="https://cdn.slidesharecdn.com/ss_thumbnails/ep2642218a1-141031160910-conversion-gate02-thumbnail.jpg?width=120&amp;height=120&amp;fit=bounds" /><br> Application number: EP20120179408 20120806 The present invention relates to an apparatus composed of three modular metal sections (1,2,3) for architectural integration of frameless laminate solar modules (M) on the inclined pitches of building roofs.
A modular apparatus for architectural integration of frameless solar modules from Claudio Liciotti
]]>
822 1 https://cdn.slidesharecdn.com/ss_thumbnails/ep2642218a1-141031160910-conversion-gate02-thumbnail.jpg?width=120&height=120&fit=bounds document Black http://activitystrea.ms/schema/1.0/post http://activitystrea.ms/schema/1.0/posted 0
IEC 62804 Status Update /slideshow/iec-62804-status-update/40839565 2014fallannarborpid62804v3-141028160540-conversion-gate02
Busan WG2 decisions – Changed from standard to technical specification. – TITLE: TEST METHODS FOR DETECTION OF POTENTIAL-­â€INDUCED DEGRADATION OF CRYSTALLINE SILICON PHOTOVOLTAIC (PV) MODULES]]>

Busan WG2 decisions – Changed from standard to technical specification. – TITLE: TEST METHODS FOR DETECTION OF POTENTIAL-­â€INDUCED DEGRADATION OF CRYSTALLINE SILICON PHOTOVOLTAIC (PV) MODULES]]>
Tue, 28 Oct 2014 16:05:40 GMT /slideshow/iec-62804-status-update/40839565 ClaudioLiciotti@slideshare.net(ClaudioLiciotti) IEC 62804 Status Update ClaudioLiciotti Busan WG2 decisions – Changed from standard to technical specification. – TITLE: TEST METHODS FOR DETECTION OF POTENTIAL-­â€INDUCED DEGRADATION OF CRYSTALLINE SILICON PHOTOVOLTAIC (PV) MODULES <img style="border:1px solid #C3E6D8;float:right;" alt="" src="https://cdn.slidesharecdn.com/ss_thumbnails/2014fallannarborpid62804v3-141028160540-conversion-gate02-thumbnail.jpg?width=120&amp;height=120&amp;fit=bounds" /><br> Busan WG2 decisions – Changed from standard to technical specification. – TITLE: TEST METHODS FOR DETECTION OF POTENTIAL-­â€INDUCED DEGRADATION OF CRYSTALLINE SILICON PHOTOVOLTAIC (PV) MODULES
IEC 62804 Status Update from Claudio Liciotti
]]>
565 3 https://cdn.slidesharecdn.com/ss_thumbnails/2014fallannarborpid62804v3-141028160540-conversion-gate02-thumbnail.jpg?width=120&height=120&fit=bounds presentation Black http://activitystrea.ms/schema/1.0/post http://activitystrea.ms/schema/1.0/posted 0
Testing modules for potential-induced degradation – a status update of IEC 62804 /slideshow/testing-modules-for-potentialinduced-degradation-a-status-update-of-iec-62804/40743542 61517-141026162442-conversion-gate02
Testing modules for potential-induced degradation – a status update of IEC 62804 Peter Hacke National Renewable Energy Laboratory (NREL) PV Module Reliability Workshop February 25-26, 2014 Golden, Colorado • IEC 62804 draft has been revised to be a method for test TEST METHOD FOR DETECTION OF POTENTIAL INDUCED DEGRADATION OF PHOTOVOLTAIC (PV) MODULES – No pass/fail criteria – Contains a foil test and a damp heat test – Provides details on how to set up tests – Provides stress conditions for use as baseline allowing for comparisons – International task group • M. Koehl (Germany) • C. Liciotti (Italy) • F. Rummens (Belgium) • F. Fabero Spain) • K. Berger (Austria) • Y. Eguchi (Japan) • P. Hacke (USA) • Comparison of stresses and degradation rate for 25° C / foil and 60°C/85% RH damp heat test • Illumination factor on PID rate • Measurement techniques and stress levels discussion]]>

Testing modules for potential-induced degradation – a status update of IEC 62804 Peter Hacke National Renewable Energy Laboratory (NREL) PV Module Reliability Workshop February 25-26, 2014 Golden, Colorado • IEC 62804 draft has been revised to be a method for test TEST METHOD FOR DETECTION OF POTENTIAL INDUCED DEGRADATION OF PHOTOVOLTAIC (PV) MODULES – No pass/fail criteria – Contains a foil test and a damp heat test – Provides details on how to set up tests – Provides stress conditions for use as baseline allowing for comparisons – International task group • M. Koehl (Germany) • C. Liciotti (Italy) • F. Rummens (Belgium) • F. Fabero Spain) • K. Berger (Austria) • Y. Eguchi (Japan) • P. Hacke (USA) • Comparison of stresses and degradation rate for 25° C / foil and 60°C/85% RH damp heat test • Illumination factor on PID rate • Measurement techniques and stress levels discussion]]>
Sun, 26 Oct 2014 16:24:42 GMT /slideshow/testing-modules-for-potentialinduced-degradation-a-status-update-of-iec-62804/40743542 ClaudioLiciotti@slideshare.net(ClaudioLiciotti) Testing modules for potential-induced degradation – a status update of IEC 62804 ClaudioLiciotti Testing modules for potential-induced degradation – a status update of IEC 62804 Peter Hacke National Renewable Energy Laboratory (NREL) PV Module Reliability Workshop February 25-26, 2014 Golden, Colorado • IEC 62804 draft has been revised to be a method for test TEST METHOD FOR DETECTION OF POTENTIAL INDUCED DEGRADATION OF PHOTOVOLTAIC (PV) MODULES – No pass/fail criteria – Contains a foil test and a damp heat test – Provides details on how to set up tests – Provides stress conditions for use as baseline allowing for comparisons – International task group • M. Koehl (Germany) • C. Liciotti (Italy) • F. Rummens (Belgium) • F. Fabero Spain) • K. Berger (Austria) • Y. Eguchi (Japan) • P. Hacke (USA) • Comparison of stresses and degradation rate for 25° C / foil and 60°C/85% RH damp heat test • Illumination factor on PID rate • Measurement techniques and stress levels discussion <img style="border:1px solid #C3E6D8;float:right;" alt="" src="https://cdn.slidesharecdn.com/ss_thumbnails/61517-141026162442-conversion-gate02-thumbnail.jpg?width=120&amp;height=120&amp;fit=bounds" /><br> Testing modules for potential-induced degradation – a status update of IEC 62804 Peter Hacke National Renewable Energy Laboratory (NREL) PV Module Reliability Workshop February 25-26, 2014 Golden, Colorado • IEC 62804 draft has been revised to be a method for test TEST METHOD FOR DETECTION OF POTENTIAL INDUCED DEGRADATION OF PHOTOVOLTAIC (PV) MODULES – No pass/fail criteria – Contains a foil test and a damp heat test – Provides details on how to set up tests – Provides stress conditions for use as baseline allowing for comparisons – International task group • M. Koehl (Germany) • C. Liciotti (Italy) • F. Rummens (Belgium) • F. Fabero Spain) • K. Berger (Austria) • Y. Eguchi (Japan) • P. Hacke (USA) • Comparison of stresses and degradation rate for 25° C / foil and 60°C/85% RH damp heat test • Illumination factor on PID rate • Measurement techniques and stress levels discussion
Testing modules for potential-induced degradation – a status update of IEC 62804 from Claudio Liciotti
]]>
1245 4 https://cdn.slidesharecdn.com/ss_thumbnails/61517-141026162442-conversion-gate02-thumbnail.jpg?width=120&height=120&fit=bounds presentation Black http://activitystrea.ms/schema/1.0/post http://activitystrea.ms/schema/1.0/posted 0
Qualità nella produzione per la "grid parity“ /slideshow/20110914-roma/40404165 20110914roma-141017105823-conversion-gate01
Qualità nella produzione per la "grid parity“ 20110914 PV Rome]]>

Qualità nella produzione per la "grid parity“ 20110914 PV Rome]]>
Fri, 17 Oct 2014 10:58:23 GMT /slideshow/20110914-roma/40404165 ClaudioLiciotti@slideshare.net(ClaudioLiciotti) Qualità nella produzione per la "grid parity“ ClaudioLiciotti Qualità nella produzione per la "grid parity“ 20110914 PV Rome <img style="border:1px solid #C3E6D8;float:right;" alt="" src="https://cdn.slidesharecdn.com/ss_thumbnails/20110914roma-141017105823-conversion-gate01-thumbnail.jpg?width=120&amp;height=120&amp;fit=bounds" /><br> Qualità nella produzione per la &quot;grid parity“ 20110914 PV Rome
Qualità nella produzione per la "grid parity“ from Claudio Liciotti
]]>
350 11 https://cdn.slidesharecdn.com/ss_thumbnails/20110914roma-141017105823-conversion-gate01-thumbnail.jpg?width=120&height=120&fit=bounds presentation Black http://activitystrea.ms/schema/1.0/post http://activitystrea.ms/schema/1.0/posted 0
Panoramica e sviluppi normativi sulla classificazione del comportamento al fuoco dei moduli fotovoltaici: la norma IEC 61730-2, la risoluzione n. 40 AREA V DCPST VVF e le indicazioni per i prodotti da costruzione /slideshow/panoramica-e-sviluppi-normativi-sulla-classificazione-del-comportamento-al-fuoco-dei-moduli-fotovoltaici-la-norma-iec-617302-la-risoluzione-n-40-area-v-dcpst-vvf-e-le-indicazioni-per-i-prodotti-da-costruzione/40403973 20130504presentazionenormativarev2-141017105321-conversion-gate01
Panoramica e sviluppi normativi sulla classificazione del comportamento al fuoco dei moduli fotovoltaici: la norma IEC 61730-2, la risoluzione n. 40 AREA V DCPST VVF e le indicazioni per i prodotti da costruzione 20130504 Solarexpo]]>

Panoramica e sviluppi normativi sulla classificazione del comportamento al fuoco dei moduli fotovoltaici: la norma IEC 61730-2, la risoluzione n. 40 AREA V DCPST VVF e le indicazioni per i prodotti da costruzione 20130504 Solarexpo]]>
Fri, 17 Oct 2014 10:53:21 GMT /slideshow/panoramica-e-sviluppi-normativi-sulla-classificazione-del-comportamento-al-fuoco-dei-moduli-fotovoltaici-la-norma-iec-617302-la-risoluzione-n-40-area-v-dcpst-vvf-e-le-indicazioni-per-i-prodotti-da-costruzione/40403973 ClaudioLiciotti@slideshare.net(ClaudioLiciotti) Panoramica e sviluppi normativi sulla classificazione del comportamento al fuoco dei moduli fotovoltaici: la norma IEC 61730-2, la risoluzione n. 40 AREA V DCPST VVF e le indicazioni per i prodotti da costruzione ClaudioLiciotti Panoramica e sviluppi normativi sulla classificazione del comportamento al fuoco dei moduli fotovoltaici: la norma IEC 61730-2, la risoluzione n. 40 AREA V DCPST VVF e le indicazioni per i prodotti da costruzione 20130504 Solarexpo <img style="border:1px solid #C3E6D8;float:right;" alt="" src="https://cdn.slidesharecdn.com/ss_thumbnails/20130504presentazionenormativarev2-141017105321-conversion-gate01-thumbnail.jpg?width=120&amp;height=120&amp;fit=bounds" /><br> Panoramica e sviluppi normativi sulla classificazione del comportamento al fuoco dei moduli fotovoltaici: la norma IEC 61730-2, la risoluzione n. 40 AREA V DCPST VVF e le indicazioni per i prodotti da costruzione 20130504 Solarexpo
Panoramica e sviluppi normativi sulla classificazione del comportamento al fuoco dei moduli fotovoltaici: la norma IEC 61730-2, la risoluzione n. 40 AREA V DCPST VVF e le indicazioni per i prodotti da costruzione from Claudio Liciotti
]]>
4455 167 https://cdn.slidesharecdn.com/ss_thumbnails/20130504presentazionenormativarev2-141017105321-conversion-gate01-thumbnail.jpg?width=120&height=120&fit=bounds presentation Black http://activitystrea.ms/schema/1.0/post http://activitystrea.ms/schema/1.0/posted 0
Progettazione a regola d’arte dei moduli per ridurre il rischio incendi /slideshow/progettazione-a-regola-darte-dei-moduli-per-ridurre-il-rischio-incendi/40403932 20130502presentazioneprogettazione-141017105222-conversion-gate01
Progettazione a regola d’arte dei moduli per ridurre il rischio incendi 20130502 presentazione progettazione]]>

Progettazione a regola d’arte dei moduli per ridurre il rischio incendi 20130502 presentazione progettazione]]>
Fri, 17 Oct 2014 10:52:22 GMT /slideshow/progettazione-a-regola-darte-dei-moduli-per-ridurre-il-rischio-incendi/40403932 ClaudioLiciotti@slideshare.net(ClaudioLiciotti) Progettazione a regola d’arte dei moduli per ridurre il rischio incendi ClaudioLiciotti Progettazione a regola d’arte dei moduli per ridurre il rischio incendi 20130502 presentazione progettazione <img style="border:1px solid #C3E6D8;float:right;" alt="" src="https://cdn.slidesharecdn.com/ss_thumbnails/20130502presentazioneprogettazione-141017105222-conversion-gate01-thumbnail.jpg?width=120&amp;height=120&amp;fit=bounds" /><br> Progettazione a regola d’arte dei moduli per ridurre il rischio incendi 20130502 presentazione progettazione
Progettazione a regola d’arte dei moduli per ridurre il rischio incendi from Claudio Liciotti
]]>
450 13 https://cdn.slidesharecdn.com/ss_thumbnails/20130502presentazioneprogettazione-141017105222-conversion-gate01-thumbnail.jpg?width=120&height=120&fit=bounds presentation Black http://activitystrea.ms/schema/1.0/post http://activitystrea.ms/schema/1.0/posted 0
Certificazione di componenti e apparati nella qualità degli impianti /slideshow/20120506-presentazione-corso-solarexpo/40403823 20120506presentazionecorsosolarexpo-141017104954-conversion-gate01
Certificazione di componenti e apparati nella qualità degli impianti 20120506 solarexpo]]>

Certificazione di componenti e apparati nella qualità degli impianti 20120506 solarexpo]]>
Fri, 17 Oct 2014 10:49:54 GMT /slideshow/20120506-presentazione-corso-solarexpo/40403823 ClaudioLiciotti@slideshare.net(ClaudioLiciotti) Certificazione di componenti e apparati nella qualità degli impianti ClaudioLiciotti Certificazione di componenti e apparati nella qualità degli impianti 20120506 solarexpo <img style="border:1px solid #C3E6D8;float:right;" alt="" src="https://cdn.slidesharecdn.com/ss_thumbnails/20120506presentazionecorsosolarexpo-141017104954-conversion-gate01-thumbnail.jpg?width=120&amp;height=120&amp;fit=bounds" /><br> Certificazione di componenti e apparati nella qualità degli impianti 20120506 solarexpo
Certificazione di componenti e apparati nella qualità degli impianti from Claudio Liciotti
]]>
1510 1 https://cdn.slidesharecdn.com/ss_thumbnails/20120506presentazionecorsosolarexpo-141017104954-conversion-gate01-thumbnail.jpg?width=120&height=120&fit=bounds presentation Black http://activitystrea.ms/schema/1.0/post http://activitystrea.ms/schema/1.0/posted 0
ANALYSIS OF THE COMBUSTION FUMES AND GASES RELEASED DURING THE BURNING OF SOME C-SI PV MODULES /slideshow/analysis-of-the-combustion-fumes-and-gases-released-during-the-burning-of-some-csi-pv-modules/39816828 5bo-141002160813-phpapp01
Along with the strong growth of PV installations, also the number of fires involving PV systems has grown. The fire risk analysis due to PV systems has been taken into strong consideration. About that, 3 were the most considered issues: 1) PV modules and components fire behavior; 2) causes of fire ignition related to PV components; 3) risk of electrocution in firefighting activities in proximity to photovoltaic generators. To protect the firefighter and to respect the environment, the type of fumes and gases that are released into the environment during a fire of a PV system should also be considered. This paper shows the analysis of the fumes and gases released during the burning and pyrolysis of some c-Si PV modules.]]>

Along with the strong growth of PV installations, also the number of fires involving PV systems has grown. The fire risk analysis due to PV systems has been taken into strong consideration. About that, 3 were the most considered issues: 1) PV modules and components fire behavior; 2) causes of fire ignition related to PV components; 3) risk of electrocution in firefighting activities in proximity to photovoltaic generators. To protect the firefighter and to respect the environment, the type of fumes and gases that are released into the environment during a fire of a PV system should also be considered. This paper shows the analysis of the fumes and gases released during the burning and pyrolysis of some c-Si PV modules.]]>
Thu, 02 Oct 2014 16:08:13 GMT /slideshow/analysis-of-the-combustion-fumes-and-gases-released-during-the-burning-of-some-csi-pv-modules/39816828 ClaudioLiciotti@slideshare.net(ClaudioLiciotti) ANALYSIS OF THE COMBUSTION FUMES AND GASES RELEASED DURING THE BURNING OF SOME C-SI PV MODULES ClaudioLiciotti Along with the strong growth of PV installations, also the number of fires involving PV systems has grown. The fire risk analysis due to PV systems has been taken into strong consideration. About that, 3 were the most considered issues: 1) PV modules and components fire behavior; 2) causes of fire ignition related to PV components; 3) risk of electrocution in firefighting activities in proximity to photovoltaic generators. To protect the firefighter and to respect the environment, the type of fumes and gases that are released into the environment during a fire of a PV system should also be considered. This paper shows the analysis of the fumes and gases released during the burning and pyrolysis of some c-Si PV modules. <img style="border:1px solid #C3E6D8;float:right;" alt="" src="https://cdn.slidesharecdn.com/ss_thumbnails/5bo-141002160813-phpapp01-thumbnail.jpg?width=120&amp;height=120&amp;fit=bounds" /><br> Along with the strong growth of PV installations, also the number of fires involving PV systems has grown. The fire risk analysis due to PV systems has been taken into strong consideration. About that, 3 were the most considered issues: 1) PV modules and components fire behavior; 2) causes of fire ignition related to PV components; 3) risk of electrocution in firefighting activities in proximity to photovoltaic generators. To protect the firefighter and to respect the environment, the type of fumes and gases that are released into the environment during a fire of a PV system should also be considered. This paper shows the analysis of the fumes and gases released during the burning and pyrolysis of some c-Si PV modules.
ANALYSIS OF THE COMBUSTION FUMES AND GASES RELEASED DURING THE BURNING OF SOME C-SI PV MODULES from Claudio Liciotti
]]>
1098 2 https://cdn.slidesharecdn.com/ss_thumbnails/5bo-141002160813-phpapp01-thumbnail.jpg?width=120&height=120&fit=bounds presentation Black http://activitystrea.ms/schema/1.0/post http://activitystrea.ms/schema/1.0/posted 0
https://cdn.slidesharecdn.com/profile-photo-ClaudioLiciotti-48x48.jpg?cb=1726309247 Since the beginning of my managerial role I was involved as Project Leader first, and Plant and Production Manager later, into the start-up of one of the major PV module manufacturer in Italy. In these roles, I dealt successfully with the complexity of a typical “green field†manufacturing start-up, fully managing all the development process: from the rump-up of the company production unit, to the kick-off of a yearly production of above 25-35 MW of PV modules, moving across the building up a well-trained organization (59 direct reports). Capitalizing on that, I become more and more expert in analyzing solutions and developing best practices on how PV modules can better interact with th www.liciotti.com https://cdn.slidesharecdn.com/ss_thumbnails/20221014presentazioneliciotti-221112154326-034c2761-thumbnail.jpg?width=320&height=320&fit=bounds slideshow/revamping-e-repowering-di-impianti-fv-accortezze-normative/254152114 Revamping e repowering... https://cdn.slidesharecdn.com/ss_thumbnails/sess-210815142524-thumbnail.jpg?width=320&height=320&fit=bounds slideshow/le-verifiche-cei-en-iec-624462-e-la-qualit-degli-impianti-fv/249984157 Le verifiche (CEI EN I... https://cdn.slidesharecdn.com/ss_thumbnails/20200508presentazioneliciotti-rev01-201121155002-thumbnail.jpg?width=320&height=320&fit=bounds slideshow/lapplicazione-delle-norme-e-i-periodi-transitori/239370867 L’applicazione delle n...