ºÝºÝߣshows by User: Emreeltik / http://www.slideshare.net/images/logo.gif ºÝºÝߣshows by User: Emreeltik / Fri, 27 Jun 2014 07:37:50 GMT ºÝºÝߣShare feed for ºÝºÝߣshows by User: Emreeltik SmartONE-LP-B_UserManual.Rev.1.5 /slideshow/smart-one-b-user-manual-rev-1-5/36378096 smartone-busermanualrev15-140627073750-phpapp01
Models Included: SmartOneA, SmartOneB, SmartOneBLP Revision: 1.5 A new version, SmartOne LP, is available. This version can be powered by line power or batteries. It can be supplied line power with the External Inputs Cable or the Serial Input Cable. Specifications: A. Input Voltage- The SmartOne LP will operate on 10 to 48 Volts DC. B. Switching- If batteries are installed, the unit will automatically switch to battery power if line power input is lost. C. Connection Method- 1. When using the Serial Input Cable, connect the voltage supply positive(+) to the VIOLET wire through a 1 Ampere Fuse. The fuse should be placed within 1 foot (30cm) of the voltage source. Connect the negative(-) source to the GRAY wire. Always use crimp connectors or solder the wires and cover the connection with shrink tubing. II. A new accessory, the Serial Input Cable, is available. This cable simplifies the sending of serial data (see page 66). In addition, it supplies access to the Dry Contact Inputs and the Line Power inputs.]]>

Models Included: SmartOneA, SmartOneB, SmartOneBLP Revision: 1.5 A new version, SmartOne LP, is available. This version can be powered by line power or batteries. It can be supplied line power with the External Inputs Cable or the Serial Input Cable. Specifications: A. Input Voltage- The SmartOne LP will operate on 10 to 48 Volts DC. B. Switching- If batteries are installed, the unit will automatically switch to battery power if line power input is lost. C. Connection Method- 1. When using the Serial Input Cable, connect the voltage supply positive(+) to the VIOLET wire through a 1 Ampere Fuse. The fuse should be placed within 1 foot (30cm) of the voltage source. Connect the negative(-) source to the GRAY wire. Always use crimp connectors or solder the wires and cover the connection with shrink tubing. II. A new accessory, the Serial Input Cable, is available. This cable simplifies the sending of serial data (see page 66). In addition, it supplies access to the Dry Contact Inputs and the Line Power inputs.]]>
Fri, 27 Jun 2014 07:37:50 GMT /slideshow/smart-one-b-user-manual-rev-1-5/36378096 Emreeltik@slideshare.net(Emreeltik) SmartONE-LP-B_UserManual.Rev.1.5 Emreeltik Models Included: SmartOneA, SmartOneB, SmartOneBLP Revision: 1.5 A new version, SmartOne LP, is available. This version can be powered by line power or batteries. It can be supplied line power with the External Inputs Cable or the Serial Input Cable. Specifications: A. Input Voltage- The SmartOne LP will operate on 10 to 48 Volts DC. B. Switching- If batteries are installed, the unit will automatically switch to battery power if line power input is lost. C. Connection Method- 1. When using the Serial Input Cable, connect the voltage supply positive(+) to the VIOLET wire through a 1 Ampere Fuse. The fuse should be placed within 1 foot (30cm) of the voltage source. Connect the negative(-) source to the GRAY wire. Always use crimp connectors or solder the wires and cover the connection with shrink tubing. II. A new accessory, the Serial Input Cable, is available. This cable simplifies the sending of serial data (see page 66). In addition, it supplies access to the Dry Contact Inputs and the Line Power inputs. <img style="border:1px solid #C3E6D8;float:right;" alt="" src="https://cdn.slidesharecdn.com/ss_thumbnails/smartone-busermanualrev15-140627073750-phpapp01-thumbnail.jpg?width=120&amp;height=120&amp;fit=bounds" /><br> Models Included: SmartOneA, SmartOneB, SmartOneBLP Revision: 1.5 A new version, SmartOne LP, is available. This version can be powered by line power or batteries. It can be supplied line power with the External Inputs Cable or the Serial Input Cable. Specifications: A. Input Voltage- The SmartOne LP will operate on 10 to 48 Volts DC. B. Switching- If batteries are installed, the unit will automatically switch to battery power if line power input is lost. C. Connection Method- 1. When using the Serial Input Cable, connect the voltage supply positive(+) to the VIOLET wire through a 1 Ampere Fuse. The fuse should be placed within 1 foot (30cm) of the voltage source. Connect the negative(-) source to the GRAY wire. Always use crimp connectors or solder the wires and cover the connection with shrink tubing. II. A new accessory, the Serial Input Cable, is available. This cable simplifies the sending of serial data (see page 66). In addition, it supplies access to the Dry Contact Inputs and the Line Power inputs.
SmartONE-LP-B_UserManual.Rev.1.5 from Emre å·½eltik
]]>
388 5 https://cdn.slidesharecdn.com/ss_thumbnails/smartone-busermanualrev15-140627073750-phpapp01-thumbnail.jpg?width=120&height=120&fit=bounds document 000000 http://activitystrea.ms/schema/1.0/post http://activitystrea.ms/schema/1.0/posted 0
Globalstar_Stx3_users_manual_18/01/2013 /slideshow/globalstarstx3usersmanual/36276844 stx3-users-manual-140625015235-phpapp02
This document describes the physical, electrical, and functional characteristics of the STX3 satellite transmitter module. The information contained in this document is intended to provide the end user with the necessary technical information required to use the module in a custom application. This document is intended to be used by engineers and technical management and assumes a general knowledge of basic engineering practices by the user.]]>

This document describes the physical, electrical, and functional characteristics of the STX3 satellite transmitter module. The information contained in this document is intended to provide the end user with the necessary technical information required to use the module in a custom application. This document is intended to be used by engineers and technical management and assumes a general knowledge of basic engineering practices by the user.]]>
Wed, 25 Jun 2014 01:52:35 GMT /slideshow/globalstarstx3usersmanual/36276844 Emreeltik@slideshare.net(Emreeltik) Globalstar_Stx3_users_manual_18/01/2013 Emreeltik This document describes the physical, electrical, and functional characteristics of the STX3 satellite transmitter module. The information contained in this document is intended to provide the end user with the necessary technical information required to use the module in a custom application. This document is intended to be used by engineers and technical management and assumes a general knowledge of basic engineering practices by the user. <img style="border:1px solid #C3E6D8;float:right;" alt="" src="https://cdn.slidesharecdn.com/ss_thumbnails/stx3-users-manual-140625015235-phpapp02-thumbnail.jpg?width=120&amp;height=120&amp;fit=bounds" /><br> This document describes the physical, electrical, and functional characteristics of the STX3 satellite transmitter module. The information contained in this document is intended to provide the end user with the necessary technical information required to use the module in a custom application. This document is intended to be used by engineers and technical management and assumes a general knowledge of basic engineering practices by the user.
Globalstar_Stx3_users_manual_18/01/2013 from Emre å·½eltik
]]>
525 5 https://cdn.slidesharecdn.com/ss_thumbnails/stx3-users-manual-140625015235-phpapp02-thumbnail.jpg?width=120&height=120&fit=bounds document 000000 http://activitystrea.ms/schema/1.0/post http://activitystrea.ms/schema/1.0/posted 0
https://cdn.slidesharecdn.com/profile-photo-Emreeltik-48x48.jpg?cb=1527600141 Sade gibi ama çok karışık, Zayıf gibi ama çok güçlü, Akıl karıştıran ama hayranlık uyandıran... https://cdn.slidesharecdn.com/ss_thumbnails/smartone-busermanualrev15-140627073750-phpapp01-thumbnail.jpg?width=320&height=320&fit=bounds slideshow/smart-one-b-user-manual-rev-1-5/36378096 SmartONE-LP-B_UserManu... https://cdn.slidesharecdn.com/ss_thumbnails/stx3-users-manual-140625015235-phpapp02-thumbnail.jpg?width=320&height=320&fit=bounds slideshow/globalstarstx3usersmanual/36276844 Globalstar_Stx3_users_...