ºÝºÝߣshows by User: ShahJalal5 / http://www.slideshare.net/images/logo.gif ºÝºÝߣshows by User: ShahJalal5 / Tue, 10 Feb 2015 06:52:37 GMT ºÝºÝߣShare feed for ºÝºÝߣshows by User: ShahJalal5 Lifting plan for bypass stack installation /slideshow/lifting-plan-for-bypass-stack-installation/44494437 liftingplanforbypassstackinstallation-150210065237-conversion-gate01
It is a big achievement for me all work done by as per my lifting plan. Especially thanks to Newaz, Rony and some our colleagues those who are assist me for make this lifting plan. I think it will be very helpful for this type of work.]]>

It is a big achievement for me all work done by as per my lifting plan. Especially thanks to Newaz, Rony and some our colleagues those who are assist me for make this lifting plan. I think it will be very helpful for this type of work.]]>
Tue, 10 Feb 2015 06:52:37 GMT /slideshow/lifting-plan-for-bypass-stack-installation/44494437 ShahJalal5@slideshare.net(ShahJalal5) Lifting plan for bypass stack installation ShahJalal5 It is a big achievement for me all work done by as per my lifting plan. Especially thanks to Newaz, Rony and some our colleagues those who are assist me for make this lifting plan. I think it will be very helpful for this type of work. <img style="border:1px solid #C3E6D8;float:right;" alt="" src="https://cdn.slidesharecdn.com/ss_thumbnails/liftingplanforbypassstackinstallation-150210065237-conversion-gate01-thumbnail.jpg?width=120&amp;height=120&amp;fit=bounds" /><br> It is a big achievement for me all work done by as per my lifting plan. Especially thanks to Newaz, Rony and some our colleagues those who are assist me for make this lifting plan. I think it will be very helpful for this type of work.
Lifting plan for bypass stack installation from Shah Jalal
]]>
9325 6 https://cdn.slidesharecdn.com/ss_thumbnails/liftingplanforbypassstackinstallation-150210065237-conversion-gate01-thumbnail.jpg?width=120&height=120&fit=bounds document 000000 http://activitystrea.ms/schema/1.0/post http://activitystrea.ms/schema/1.0/posted 0
Mechanical Transmission /slideshow/couplings-44485187/44485187 couplings-150210025045-conversion-gate02
I want this job to utilize the skills which I've gotten from my Boss, colleague and others. I will utilize this knowledge for the success of you and for my personal success. I will prove myself by my job.]]>

I want this job to utilize the skills which I've gotten from my Boss, colleague and others. I will utilize this knowledge for the success of you and for my personal success. I will prove myself by my job.]]>
Tue, 10 Feb 2015 02:50:45 GMT /slideshow/couplings-44485187/44485187 ShahJalal5@slideshare.net(ShahJalal5) Mechanical Transmission ShahJalal5 I want this job to utilize the skills which I've gotten from my Boss, colleague and others. I will utilize this knowledge for the success of you and for my personal success. I will prove myself by my job. <img style="border:1px solid #C3E6D8;float:right;" alt="" src="https://cdn.slidesharecdn.com/ss_thumbnails/couplings-150210025045-conversion-gate02-thumbnail.jpg?width=120&amp;height=120&amp;fit=bounds" /><br> I want this job to utilize the skills which I&#39;ve gotten from my Boss, colleague and others. I will utilize this knowledge for the success of you and for my personal success. I will prove myself by my job.
Mechanical Transmission from Shah Jalal
]]>
8602 4 https://cdn.slidesharecdn.com/ss_thumbnails/couplings-150210025045-conversion-gate02-thumbnail.jpg?width=120&height=120&fit=bounds presentation 000000 http://activitystrea.ms/schema/1.0/post http://activitystrea.ms/schema/1.0/posted 0
Lifting plan for inlet duct removal /slideshow/lifting-plan-for-inlet-duct-removal/44404733 liftingplanforinletductremoval-150208074629-conversion-gate01
I want to utilize my analytical expertise to help people meet their exertion goals. This work to give me an even more extensive knowledge of my experience as a plan architect, I am very proud of my colleagues thus who are assist me for construct this plan.]]>

I want to utilize my analytical expertise to help people meet their exertion goals. This work to give me an even more extensive knowledge of my experience as a plan architect, I am very proud of my colleagues thus who are assist me for construct this plan.]]>
Sun, 08 Feb 2015 07:46:29 GMT /slideshow/lifting-plan-for-inlet-duct-removal/44404733 ShahJalal5@slideshare.net(ShahJalal5) Lifting plan for inlet duct removal ShahJalal5 I want to utilize my analytical expertise to help people meet their exertion goals. This work to give me an even more extensive knowledge of my experience as a plan architect, I am very proud of my colleagues thus who are assist me for construct this plan. <img style="border:1px solid #C3E6D8;float:right;" alt="" src="https://cdn.slidesharecdn.com/ss_thumbnails/liftingplanforinletductremoval-150208074629-conversion-gate01-thumbnail.jpg?width=120&amp;height=120&amp;fit=bounds" /><br> I want to utilize my analytical expertise to help people meet their exertion goals. This work to give me an even more extensive knowledge of my experience as a plan architect, I am very proud of my colleagues thus who are assist me for construct this plan.
Lifting plan for inlet duct removal from Shah Jalal
]]>
2352 4 https://cdn.slidesharecdn.com/ss_thumbnails/liftingplanforinletductremoval-150208074629-conversion-gate01-thumbnail.jpg?width=120&height=120&fit=bounds document 000000 http://activitystrea.ms/schema/1.0/post http://activitystrea.ms/schema/1.0/posted 0
Assembly and Disassembly Procedure of Screw type Compressor /ShahJalal5/overhauling-procedure-for-fgc overhaulingprocedureforfgc-150128073551-conversion-gate02
The Procedure will be very much helpful for complete overhauling of Screw type Compressor .The Maintenance Procedure is for Fuel Gas Compressor(KOBELCO) of 450 MW Meghnaghat Power Plant.]]>

The Procedure will be very much helpful for complete overhauling of Screw type Compressor .The Maintenance Procedure is for Fuel Gas Compressor(KOBELCO) of 450 MW Meghnaghat Power Plant.]]>
Wed, 28 Jan 2015 07:35:50 GMT /ShahJalal5/overhauling-procedure-for-fgc ShahJalal5@slideshare.net(ShahJalal5) Assembly and Disassembly Procedure of Screw type Compressor ShahJalal5 The Procedure will be very much helpful for complete overhauling of Screw type Compressor .The Maintenance Procedure is for Fuel Gas Compressor(KOBELCO) of 450 MW Meghnaghat Power Plant. <img style="border:1px solid #C3E6D8;float:right;" alt="" src="https://cdn.slidesharecdn.com/ss_thumbnails/overhaulingprocedureforfgc-150128073551-conversion-gate02-thumbnail.jpg?width=120&amp;height=120&amp;fit=bounds" /><br> The Procedure will be very much helpful for complete overhauling of Screw type Compressor .The Maintenance Procedure is for Fuel Gas Compressor(KOBELCO) of 450 MW Meghnaghat Power Plant.
Assembly and Disassembly Procedure of Screw type Compressor from Shah Jalal
]]>
13239 9 https://cdn.slidesharecdn.com/ss_thumbnails/overhaulingprocedureforfgc-150128073551-conversion-gate02-thumbnail.jpg?width=120&height=120&fit=bounds document 000000 http://activitystrea.ms/schema/1.0/post http://activitystrea.ms/schema/1.0/posted 0
Circulating Water Pump Overhauling Report (Capacity- 29,000 m3/hr) /ShahJalal5/overhauling-report-2014 overhaulingreport-2014-140910235557-phpapp01
The pump suction is from river water to discharge to water boxes of steam condenser. It’s a vertical shaft, 2,100 discharge bore mixed flow pump. It’s driven by an 1650 KW vertically mounted motor with a rated full load rpm of 372. Rated flow rate of the pump is 29,000 m3/hr]]>

The pump suction is from river water to discharge to water boxes of steam condenser. It’s a vertical shaft, 2,100 discharge bore mixed flow pump. It’s driven by an 1650 KW vertically mounted motor with a rated full load rpm of 372. Rated flow rate of the pump is 29,000 m3/hr]]>
Wed, 10 Sep 2014 23:55:57 GMT /ShahJalal5/overhauling-report-2014 ShahJalal5@slideshare.net(ShahJalal5) Circulating Water Pump Overhauling Report (Capacity- 29,000 m3/hr) ShahJalal5 The pump suction is from river water to discharge to water boxes of steam condenser. It’s a vertical shaft, 2,100 discharge bore mixed flow pump. It’s driven by an 1650 KW vertically mounted motor with a rated full load rpm of 372. Rated flow rate of the pump is 29,000 m3/hr <img style="border:1px solid #C3E6D8;float:right;" alt="" src="https://cdn.slidesharecdn.com/ss_thumbnails/overhaulingreport-2014-140910235557-phpapp01-thumbnail.jpg?width=120&amp;height=120&amp;fit=bounds" /><br> The pump suction is from river water to discharge to water boxes of steam condenser. It’s a vertical shaft, 2,100 discharge bore mixed flow pump. It’s driven by an 1650 KW vertically mounted motor with a rated full load rpm of 372. Rated flow rate of the pump is 29,000 m3/hr
Circulating Water Pump Overhauling Report (Capacity- 29,000 m3/hr) from Shah Jalal
]]>
3073 3 https://cdn.slidesharecdn.com/ss_thumbnails/overhaulingreport-2014-140910235557-phpapp01-thumbnail.jpg?width=120&height=120&fit=bounds document Black http://activitystrea.ms/schema/1.0/post http://activitystrea.ms/schema/1.0/posted 0
6.6 KV MOTOR BREAKDOWN MAINTENANCE REPORT /slideshow/66-kv-38683715/38683715 6-140904033400-phpapp01
this report will be very help full us for motor breakdown maintenance]]>

this report will be very help full us for motor breakdown maintenance]]>
Thu, 04 Sep 2014 03:34:00 GMT /slideshow/66-kv-38683715/38683715 ShahJalal5@slideshare.net(ShahJalal5) 6.6 KV MOTOR BREAKDOWN MAINTENANCE REPORT ShahJalal5 this report will be very help full us for motor breakdown maintenance <img style="border:1px solid #C3E6D8;float:right;" alt="" src="https://cdn.slidesharecdn.com/ss_thumbnails/6-140904033400-phpapp01-thumbnail.jpg?width=120&amp;height=120&amp;fit=bounds" /><br> this report will be very help full us for motor breakdown maintenance
6.6 KV MOTOR BREAKDOWN MAINTENANCE REPORT from Shah Jalal
]]>
2113 3 https://cdn.slidesharecdn.com/ss_thumbnails/6-140904033400-phpapp01-thumbnail.jpg?width=120&height=120&fit=bounds document Black http://activitystrea.ms/schema/1.0/post http://activitystrea.ms/schema/1.0/posted 0
By Pass Control Valve Maintenance /slideshow/by-pass-control-valve-maintenance/37841845 bypasscontrolvalvemaintenance-140810062525-phpapp01
Bypass control valve main function is to control steam during start up and shutdown of Steam Turbine especially it reduces the pressure and temperature of the steam and fed it to the cold reheat line.]]>

Bypass control valve main function is to control steam during start up and shutdown of Steam Turbine especially it reduces the pressure and temperature of the steam and fed it to the cold reheat line.]]>
Sun, 10 Aug 2014 06:25:25 GMT /slideshow/by-pass-control-valve-maintenance/37841845 ShahJalal5@slideshare.net(ShahJalal5) By Pass Control Valve Maintenance ShahJalal5 Bypass control valve main function is to control steam during start up and shutdown of Steam Turbine especially it reduces the pressure and temperature of the steam and fed it to the cold reheat line. <img style="border:1px solid #C3E6D8;float:right;" alt="" src="https://cdn.slidesharecdn.com/ss_thumbnails/bypasscontrolvalvemaintenance-140810062525-phpapp01-thumbnail.jpg?width=120&amp;height=120&amp;fit=bounds" /><br> Bypass control valve main function is to control steam during start up and shutdown of Steam Turbine especially it reduces the pressure and temperature of the steam and fed it to the cold reheat line.
By Pass Control Valve Maintenance from Shah Jalal
]]>
736 4 https://cdn.slidesharecdn.com/ss_thumbnails/bypasscontrolvalvemaintenance-140810062525-phpapp01-thumbnail.jpg?width=120&height=120&fit=bounds document Black http://activitystrea.ms/schema/1.0/post http://activitystrea.ms/schema/1.0/posted 0
https://cdn.slidesharecdn.com/profile-photo-ShahJalal5-48x48.jpg?cb=1638883541 * Now I have been working in Mesaideed Power Limited (2,000 MW CCPP of ISO14001 and OSHAS 18001 Certified company) as a Mechanical Maintenance Technician since 3rd May 2015. I am expert at problem-resolution, maintenance & managing projects from inception through completion maintaining safety regulations. I have experienced in supervising all levels of technicians and building relationships with the foreign staff. * Experience on supervision of all types of Rotating equipments (Steam turbines , Gas turbines, Centrifugal Compressors, Screw Compressors, high pressure multistage pumps, etc.) * Stationary equipments ( High Pressure steam drums, ST Condenser, Heat Recovery Steam Generator (... https://cdn.slidesharecdn.com/ss_thumbnails/liftingplanforbypassstackinstallation-150210065237-conversion-gate01-thumbnail.jpg?width=320&height=320&fit=bounds slideshow/lifting-plan-for-bypass-stack-installation/44494437 Lifting plan for bypas... https://cdn.slidesharecdn.com/ss_thumbnails/couplings-150210025045-conversion-gate02-thumbnail.jpg?width=320&height=320&fit=bounds slideshow/couplings-44485187/44485187 Mechanical Transmission https://cdn.slidesharecdn.com/ss_thumbnails/liftingplanforinletductremoval-150208074629-conversion-gate01-thumbnail.jpg?width=320&height=320&fit=bounds slideshow/lifting-plan-for-inlet-duct-removal/44404733 Lifting plan for inlet...