1. Transmission Line Theory
Transmission Line Theory
Introduction:
Introduction:
In an electronic system, the delivery of power
In an electronic system, the delivery of power
requires the connection of two wires between the source
requires the connection of two wires between the source
and the load. At low frequencies, power is considered to
and the load. At low frequencies, power is considered to
be delivered to the load through the wire.
be delivered to the load through the wire.
In the microwave frequency region, power is
In the microwave frequency region, power is
considered to be in electric and magnetic fields that are
considered to be in electric and magnetic fields that are
guided from lace to place by some physical structure. Any
guided from lace to place by some physical structure. Any
physical structure that will guide an electromagnetic wave
physical structure that will guide an electromagnetic wave
place to place is called a
place to place is called a Transmission Line
Transmission Line.
.
2. Types of Transmission Lines
Types of Transmission Lines
1.
1. Two wire line
Two wire line
2.
2. Coaxial cable
Coaxial cable
3.
3. Waveguide
Waveguide
Rectangular
Rectangular
Circular
Circular
4.
4. Planar Transmission Lines
Planar Transmission Lines
Strip line
Strip line
Microstrip line
Microstrip line
Slot line
Slot line
Fin line
Fin line
Coplanar Waveguide
Coplanar Waveguide
Coplanar slot line
Coplanar slot line
3. Analysis of differences between Low
Analysis of differences between Low
and High Frequency
and High Frequency
At low frequencies, the circuit elements are lumped since
At low frequencies, the circuit elements are lumped since
voltage and current waves affect the entire circuit at the same
voltage and current waves affect the entire circuit at the same
time.
time.
At microwave frequencies, such treatment of circuit elements
At microwave frequencies, such treatment of circuit elements
is not possible since voltag and current waves do not affect the
is not possible since voltag and current waves do not affect the
entire circuit at the same time.
entire circuit at the same time.
The circuit must be broken down into unit sections within
The circuit must be broken down into unit sections within
which the circuit elements are considered to be lumped.
which the circuit elements are considered to be lumped.
This is because the dimensions of the circuit are comparable to
This is because the dimensions of the circuit are comparable to
the wavelength of the waves according to the formula:
the wavelength of the waves according to the formula:
緒
緒c/f
c/f
where,
where,
c = velocity of light
c = velocity of light
f = frequency of voltage/current
f = frequency of voltage/current
4. Transmission Line Concepts
Transmission Line Concepts
The transmission line is divided into small units where the
The transmission line is divided into small units where the
circuit elements can be lumped.
circuit elements can be lumped.
Assuming the resistance of the lines is zero, then the
Assuming the resistance of the lines is zero, then the
transmission line can be modeled as an LC ladder
transmission line can be modeled as an LC ladder
network with inductors in the series arms and the
network with inductors in the series arms and the
capacitors in the shunt arms.
capacitors in the shunt arms.
The value of inductance and capacitance of each part
The value of inductance and capacitance of each part
determines the velocity of propagation of energy down the
determines the velocity of propagation of energy down the
line.
line.
Time taken for a wave to travel one unit length is equal to
Time taken for a wave to travel one unit length is equal to
T(s) = (LC)
T(s) = (LC)0.5
0.5
Velocity of the wave is equal to
Velocity of the wave is equal to
v (m/s) = 1/T
v (m/s) = 1/T
Impedance at any point is equal to
Impedance at any point is equal to
Z = V (at any point)/I (at any point)
Z = V (at any point)/I (at any point)
Z = (L/C)
Z = (L/C)0.5
0.5
5. Line terminated in its characteristic
impedance: If the end of the transmission line is
terminated in a resistor equal in value to the
characteristic impedance of the line as calculated
by the formula Z=(L/C)0.5
, then the voltage and
current are compatible and no reflections occur.
Line terminated in a short: When the end of the
transmission line is terminated in a short (RL = 0),
the voltage at the short must be equal to the
product of the current and the resistance.
Line terminated in an open: When the line is
terminated in an open, the resistance between the
open ends of the line must be infinite. Thus the
current at the open end is zero.
6. Reflection from Resistive loads
Reflection from Resistive loads
When the resistive load termination is not equal to the
When the resistive load termination is not equal to the
characteristic impedance, part of the power is reflected
characteristic impedance, part of the power is reflected
back and the remainder is absorbed by the load. The
back and the remainder is absorbed by the load. The
amount of voltage reflected back is called
amount of voltage reflected back is called voltage
voltage
reflection coefficient.
reflection coefficient.
緒
緒V
Vr
r/V
/Vi
i
where V
where Vr
r = incident voltage
= incident voltage
V
Vi
i = reflected voltage
= reflected voltage
The reflection coefficient is also given by
The reflection coefficient is also given by
= (Z
= (ZL
L - Z
- ZO
O)/(Z
)/(ZL
L + Z
+ ZO
O)
)
7. Standing Waves
Standing Waves
A standing wave is formed by the addition of incident and reflected
A standing wave is formed by the addition of incident and reflected
waves and has nodal points that remain stationary with time.
waves and has nodal points that remain stationary with time.
Voltage Standing Wave Ratio:
Voltage Standing Wave Ratio:
VSWR = V
VSWR = Vmax
max/V
/Vmin
min
Voltage standing wave ratio expressed in decibels is called the
Voltage standing wave ratio expressed in decibels is called the Standing
Standing
Wave Ratio:
Wave Ratio:
SWR (dB) = 20log
SWR (dB) = 20log10
10VSWR
VSWR
The maximum impedance of the line is given by:
The maximum impedance of the line is given by:
Z
Zmax
max = V
= Vmax
max/I
/Imin
min
The minimum impedance of the line is given by:
The minimum impedance of the line is given by:
Z
Zmin
min = V
= Vmin
min/I
/Imax
max
or alternatively:
or alternatively:
Z
Zmin
min = Z
= Zo
o/VSWR
/VSWR
Relationship between VSWR and Reflection Coefficient:
Relationship between VSWR and Reflection Coefficient:
VSWR = (1 +
VSWR = (1 + 種種
種種1 -
1 - 種種
種種
緒
緒(VSWR 1)/(VSWR + 1)
(VSWR 1)/(VSWR + 1)
8. General Input Impedance Equation
Input impedance of a transmission line at a
distance L from the load impedance ZL with a
characteristic Zo is
Zinput = Zo [(ZL + j Zo BL)/(Zo + j ZL BL)]
where B is called phase constant or
wavelength constant and is defined by the
equation
B = 2逸
9. Half and Quarter wave transmission lines
Half and Quarter wave transmission lines
The relationship of the input impedance at the
The relationship of the input impedance at the
input of the half-wave transmission line with its
input of the half-wave transmission line with its
terminating impedance is got by letting L =
terminating impedance is got by letting L = 駕
駕in
in
the impedance equation.
the impedance equation.
Z
Zinput
input = Z
= ZL
L
The relationship of the input impedance at the
The relationship of the input impedance at the
input of the quarter-wave transmission line with
input of the quarter-wave transmission line with
its terminating impedance is got by letting L =
its terminating impedance is got by letting L =
駕
駕in the impedance equation.
in the impedance equation.
Z
Zinput
input = (Z
= (Zinput
input Z
Zoutput
output)
)0.5
0.5
10. Effect of Lossy line on voltage and
Effect of Lossy line on voltage and
current waves
current waves
The effect of resistance in a transmission line is to continuously
The effect of resistance in a transmission line is to continuously
reduce the amplitude of both incident and reflected voltage and
reduce the amplitude of both incident and reflected voltage and
current waves.
current waves.
Skin Effect:
Skin Effect: As frequency increases, depth of penetration into
As frequency increases, depth of penetration into
adjacent conductive surfaces decreases for boundary currents
adjacent conductive surfaces decreases for boundary currents
associated with electromagnetic waves. This results in the
associated with electromagnetic waves. This results in the
confinement of the voltage and current waves at the boundary of
confinement of the voltage and current waves at the boundary of
the transmission line, thus making the transmission more lossy.
the transmission line, thus making the transmission more lossy.
The skin depth is given by:
The skin depth is given by:
skin depth (m) = 1
skin depth (m) = 1逸
逸f
f
0.5
0.5
where f = frequency, Hz
where f = frequency, Hz
= permeability, H/m
= permeability, H/m
э
э= conductivity, S/m
= conductivity, S/m
11. Smith chart
Smith chart
For complex transmission line problems, the use of
For complex transmission line problems, the use of
the formulae becomes increasingly difficult and
the formulae becomes increasingly difficult and
inconvenient. An indispensable graphical method of
inconvenient. An indispensable graphical method of
solution is the use of Smith Chart.
solution is the use of Smith Chart.
12. Components of a Smith Chart
Components of a Smith Chart
Horizontal line:
Horizontal line: The horizontal line running through the
The horizontal line running through the
center of the Smith chart represents either the resistive ir the
center of the Smith chart represents either the resistive ir the
conductive component. Zero resistance or conductance is
conductive component. Zero resistance or conductance is
located on the left end and infinite resistance or conductance is
located on the left end and infinite resistance or conductance is
located on the right end of the line.
located on the right end of the line.
Circles of constant resistance and conductance:
Circles of constant resistance and conductance: Circles of
Circles of
constant resistance are drawn on the Smith chart tangent to the
constant resistance are drawn on the Smith chart tangent to the
right-hand side of the chart and its intersection with the
right-hand side of the chart and its intersection with the
centerline. These circles of constant resistance are used to
centerline. These circles of constant resistance are used to
locate complex impedances and to assist in obtaining solutions
locate complex impedances and to assist in obtaining solutions
to problems involving the Smith chart.
to problems involving the Smith chart.
Lines of constant reactance:
Lines of constant reactance: Lines of constant reactance are
Lines of constant reactance are
shown on the Smith chart with curves that start from a given
shown on the Smith chart with curves that start from a given
reactance value on the outer circle and end at the right-hand
reactance value on the outer circle and end at the right-hand
side of the center line.
side of the center line.
13. Solutions to Microwave problems using Smith chart
The types of problems for which Smith charts are used
include the following:
1. Plotting a complex impedance on a Smith chart
2. Finding VSWR for a given load
3. Finding the admittance for a given impedance
4. Finding the input impedance of a transmission line terminated
in a short or open.
5. Finding the input impedance at any distance from a load ZL.
6. Locating the first maximum and minimum from any load
7. Matching a transmission line to a load with a single series
stub.
8. Matching a transmission line with a single parallel stub
9. Matching a transmission line to a load with two parallel stubs.
14. Plotting a Complex Impedance on a Smith Chart
To locate a complex impedance, Z = R+-jX or
admittance Y = G +- jB on a Smith chart,
normalize the real and imaginary part of the
complex impedance. Locating the value of the
normalized real term on the horizontal line scale
locates the resistance circle. Locating the
normalized value of the imaginary term on the
outer circle locates the curve of constant
reactance. The intersection of the circle and the
curve locates the complex impedance on the
Smith chart.
15. Finding the VSWR for a given load
Normalize the load and plot its location on
the Smith chart.
Draw a circle with a radius equal to the
distance between the 1.0 point and the
location of the normalized load and the
center of the Smith chart as the center.
The intersection of the right-hand side of
the circle with the horizontal resistance
line locates the value of the VSWR.
16. Finding the Input Impedance at any
Distance from the Load
The load impedance is first normalized and is
located on the Smith chart.
The VSWR circle is drawn for the load.
A line is drawn from the 1.0 point through the
load to the outer wavelength scale.
To locate the input impedance on a Smith chart
of the transmission line at any given distance
from the load, advance in clockwise direction
from the located point, a distance in wavelength
equal to the distance to the new location on the
transmission line.
17. Power Loss
Return Power Loss: When an electromagnetic wave
travels down a transmission line and encounters a
mismatched load or a discontinuity in the line, part of the
incident power is reflected back down the line. The return
loss is defined as:
Preturn = 10 log10 Pi/Pr
Preturn = 20 log10 1/
Mismatch Power Loss: The term mismatch loss is used
to describe the loss caused by the reflection due to a
mismatched line. It is defined as
Pmismatch = 10 log10 Pi/(Pi - Pr)
18. Microwave Components
Microwave components do the following functions:
1. Terminate the wave
2. Split the wave into paths
3. Control the direction of the wave
4. Switch power
5. Reduce power
6. Sample fixed amounts of power
7. Transmit or absorb fixed frequencies
8. Transmit power in one direction
9. Shift the phase of the wave
10. Detect and mix waves
19. Coaxial components
Connectors: Microwave coaxial connectors required to connect two
coaxial lines are als called connector pairs (male and female). They
must match the characteristic impedance of the attached lines and be
designed to have minimum reflection coefficients and not radiate
power through the connector.
E.g. APC-3.5, BNC, SMA, SMC, Type N
Coaxial sections: Coaxial line sections slip inside each other while
still making electrical contact. These sections are useful for matching
loads and making slotted line measurements. Double and triple stub
tuning configurations are available as coaxial stub tuning sections.
Attenuators: The function of an attenuator is to reduce the power of
the signal through it by a fixed or adjustable amount. The different
types of attenuators are:
1. Fixed attenuators
2. Step attenuators
3. Variable attenuators
20. Coaxial components (contd.)
Coaxial cavities: Coaxial cavities are
concentric lines or coaxial lines with an air
dielectric and closed ends. Propagation of
EM waves is in TEM mode.
Coaxial wave meters: Wave meters use a
cavity to allow the transmission or absorption
of a wave at a frequency equal to the
resonant frequency of the cavity. Coaxial
cavities are used as wave meters.
22. Tees
Hybrid Tee junction: Tee junctions are used
to split waves from one waveguide to two
other waveguides. There are two ways of
connecting the third arm to the waveguide
1. along the long dimension, called E=plane Tee.
2. along the narrow dimension, called H-Plane Tee
Hybrid Tee junction: the E-plane and H-
plane tees can be combined to form a
hybrid tee junction called Magic Tee
23. Attenuators
Attenuators are components that reduce the amount of power a fixed
amount, a variable amount or in a series of fixed steps from the input
to the output of the device. They operate on the principle of interfering
with the electric field or magnetic field or both.
際際滷 vane attenuators: They work on the principle that a resistive
material placed in parallel with the E-lines of a field current will induce
a current in the material that will result in I2
R power loss.
Flap attenuator: A flap attenuator has a vane that is dropped into the
waveguide through a slot in the top of the guide. The further the vane
is inserted into the waveguide, the greater the attenuation.
Rotary vane attenuator: It is a precision waveguide attenuator in which
attenuation follows a mathematical law. In this device, attenuation is
independent on frequency.
24. Isolators
Mismatch or discontinuities cause energy to be reflected back
down the line. Reflected energy is undesirable. Thus, to
prevent reflected energy from reaching the source, isolators are
used.
Faraday Rotational Isolator: It combines ferrite material to
shift the phase of an electromagnetic wave in its vicinity and
attenuation vanes to attenuate an electric field that is parallel to
the resistive plane.
Resonant absorption isolator: A device that can be used for
higher powers. It consists of a section of rectangular waveguide
with ferrite material placed half way to the center of the
waveguide, along the axis of the guide.