This document provides information about the design of a performance venue. It includes details about the main entrance, which is a glass chamber supported by steel beams and covered in wood. The interior structure allows natural light and presents the architect's philosophy of material exposure. Floor plans indicate total seating is 801, with 6 public and 2 private entrances. The stage is 12m x 15m with a 2' height and 90 degree viewing angle from the center. Ceiling design reduces reverberation for performance and provides light, fire resistance and access to building systems. Mechanical, electrical and fire protection systems are also outlined.
15. MAIN ENTRANCE
MAIN ENTRANCE IS A GLASS CHAMBER SUPPORTED WITH STEEL BEAMS COVERED
WITH WOODEN PLATES AND COLUMNS, IT HAS TWO MAIN ENTRANCES WITH 7’10”
HEIGHT AND 6’2” WIDE THE AREA OF THE GLASS CHAMBER IS 900 SQ FT. APPROX,
THE CHMABER IS ON BOTH SIDES OF THE AUDITORIUM BUT THE CHMABER TOWARDS
THE MAIN ENTRANCE IS FUNCTIONAL.
INTERIORS
16. THE STRUCTURE OF THE CHAMBER IS FABRICATION.
THE STRUCTURE ALLOWS THE NATURAL LIGHTNING
AND GIVES NATURALNESS AND PRESENTS
CORBUSIER’S PHILOSPHY OF MATERIAL EXPOSURE.
23. ? Stage has an area
of 12mx15m.
? The height of the
stage is 2’.
? The angle of view
from center of
stage is 90 degrees.
? Wooden flooring
is used.
? Distance between
stage and front
row is 3’.
24. The ceiling used for
reducing reverberation
time, it provides important
performance attributes such
as light reflectants, fire
resistance and easy
accessibility to building
systems.
26. CHILLER
A chiller is a machine that removes heat from a
liquid via a vapor compression or absorption
refrigeration cycle. This liquid can then be
circulated through a heat exchanger to cool air or
equipment as required.
AC PLANT
27. FIRE PUMP HOUSE
Fire pump is a part of a fire system
which stores water in case of
emergency and pumps it through
fire fighting units.
AC DUCT
CENTRAL HEATING SYSTEM
A central heating system provides warmth to the whole interior of a
building (or portion of a building) from one point to multiple rooms.
When combined with other systems in order to control the
building climate, the whole system may be an HVAC
29. FIRE EXTINGUISHER
A fire extinguisher, or extinguisher, is
an active fire protection device used to
extinguish or control small fires
FIRE HOSE CABINATS
A fire hose is a high-pressure hose that
carries water or other fire retardant (such as foam)
to a fire to extinguish it. Outdoors, it attaches either
to a fire engine or a fire hydrant. Indoors, it can
permanently attach to a
building's standpipe or plumbing system.
FIRE SPRINKLER
A fire sprinkler or sprinkler head is
the component of a fire sprinkler
system that discharges water when the
effects of a fire have been detected,
such as when a predetermined
temperature has been exceeded.
SMOKE DETECTOR
A smoke detector is a device that senses
smoke, typically as an indicator of fire.