INDUSTRIAL TRAINING
Leela Electric Power Services
Pvt. Ltd., Ernakulam
01-May-2015 to 30-May-2015
Plot
 About the company
 Work Flow
 A Case Study
 Gallery
 Conclusion
Leela Electric Power Services Pvt. Ltd.
 Consultancy of Power Distribution
 Estimation & Design of Electrical Schematic
 Erection, Testing and Commissioning of
Transformers up to 2000KVA and HV/MV
switchboards
Leela Electric Power Services Pvt. Ltd.
 Erection of Control panel and its wiring
 Erection of 2-pole,4-pole and 6-pole receiving
structure and allied works
 End termination of HT cables up to 33KVA
WORK FLOW
DESIGN
 Starts from load side
 Based on Standards by Electrical Inspectorate
 Fault Level Calculation & Earthing Scheme
 Per Motor Design
 Switch
 Fuse
 Isolation (MCB, MCCB, SFU and MPCB)
 Cable
STANDARDS
 Chief Electrical Inspectorate, Govt. Of Kerala
 http://www.cei.kerala.gov.in
 Norms and conditions
 Eg.
 Power Distribution Board
 3000 W or 2 Points
 Low Voltage Distribution Board
 800 W or 10 Points
EARTHING
 Body Earthing of Equipments
 Earthing Scheme & Grid Formation
 Earthing wire
 Fault level variation according to place of fault
 Copper  Aluminum  Galvanized Iron
EARTHING
EARTH PLATE
 Copper and GI plates
 60 cm x 60 cm x 3 mm / 6
mm ( Min. Dimension)
 No. of plates based on
fault level
PLATE EARTHING
PLATE EARTHING
51G Earth Fault Relay
 Inverse time over
current relay
 Severe fault  Fast
tripping
 Main protection relay
used below 500kVA
A2XFY cable
 A  Aluminum
 2X  XLPE insulation
 F/ Fa  Steel strip armor variations
 W/Ww/Wa  Steel round wire armor
variations
 Y  PVC outer sheath
 C/CE  Metallic screening
INDUSTRIAL TRAINING
Basic Architecture of a Control Panel
INTERLOCK
 Why interlocking ?
 Methods
 Automatic Mains Failure Relay (AMF)
 Castell Key Mechanism
 Crusher Loads
 The plant never sleeps
 High speed interlock required
 Automatic Transfer Switch (ATS) is used
Automatic Transfer Switch
 Monitors Voltage and Frequency
 Fast switching (30 Cycles)
 Synchronization
 Two live lines handling simultaneously
Automatic Power Factor Correction
Panel
 Optimize energy
consumption
 Increase the power
availability
 Reduced KVA
requirement
 Reduce harmonic
distortion
ISOLATION
EQUIPMENT
ORDER
RATING
MCB Less than 500 A
MCCB 500 to 1 kA
ACB, VCB, SF6 above 1 kA
MCCB and MCB
 Difference ?
 3- Phase 4/6 way TPN MCB DB
 4/6 ways in each phase
 Percentage tripping
requirement ?
TOD Meter
 Time of Use Meter
 Peak and Off Peak Slabs
 Measures
 When Energy is Consumed
 How much Energy is Consumed
CASE STUDY
 Avees Food Products, Pulincunnoo, Aleppy
 Washing
 Powdering
 Roasting
 Grading
 Packing
 Load Requirement
 290.75 HP
 14.7 kW
 80 kVAr
Glanding
Cable Termination Kit
CONCLUSION
 HT wiring Design and Standards is familiarized
 Workflow and Procedures are familiarized
 Techniques like cable glanding and
termination are familiarized
 AUTOCADD electrical drawings are familiarized
THANK YOU ALL VERY MUCH

More Related Content

INDUSTRIAL TRAINING

  • 1. INDUSTRIAL TRAINING Leela Electric Power Services Pvt. Ltd., Ernakulam 01-May-2015 to 30-May-2015
  • 2. Plot About the company Work Flow A Case Study Gallery Conclusion
  • 3. Leela Electric Power Services Pvt. Ltd. Consultancy of Power Distribution Estimation & Design of Electrical Schematic Erection, Testing and Commissioning of Transformers up to 2000KVA and HV/MV switchboards
  • 4. Leela Electric Power Services Pvt. Ltd. Erection of Control panel and its wiring Erection of 2-pole,4-pole and 6-pole receiving structure and allied works End termination of HT cables up to 33KVA
  • 6. DESIGN Starts from load side Based on Standards by Electrical Inspectorate Fault Level Calculation & Earthing Scheme Per Motor Design Switch Fuse Isolation (MCB, MCCB, SFU and MPCB) Cable
  • 7. STANDARDS Chief Electrical Inspectorate, Govt. Of Kerala http://www.cei.kerala.gov.in Norms and conditions Eg. Power Distribution Board 3000 W or 2 Points Low Voltage Distribution Board 800 W or 10 Points
  • 8. EARTHING Body Earthing of Equipments Earthing Scheme & Grid Formation Earthing wire Fault level variation according to place of fault Copper Aluminum Galvanized Iron
  • 10. EARTH PLATE Copper and GI plates 60 cm x 60 cm x 3 mm / 6 mm ( Min. Dimension) No. of plates based on fault level
  • 13. 51G Earth Fault Relay Inverse time over current relay Severe fault Fast tripping Main protection relay used below 500kVA
  • 14. A2XFY cable A Aluminum 2X XLPE insulation F/ Fa Steel strip armor variations W/Ww/Wa Steel round wire armor variations Y PVC outer sheath C/CE Metallic screening
  • 16. Basic Architecture of a Control Panel
  • 17. INTERLOCK Why interlocking ? Methods Automatic Mains Failure Relay (AMF) Castell Key Mechanism Crusher Loads The plant never sleeps High speed interlock required Automatic Transfer Switch (ATS) is used
  • 18. Automatic Transfer Switch Monitors Voltage and Frequency Fast switching (30 Cycles) Synchronization Two live lines handling simultaneously
  • 19. Automatic Power Factor Correction Panel Optimize energy consumption Increase the power availability Reduced KVA requirement Reduce harmonic distortion
  • 20. ISOLATION EQUIPMENT ORDER RATING MCB Less than 500 A MCCB 500 to 1 kA ACB, VCB, SF6 above 1 kA
  • 21. MCCB and MCB Difference ? 3- Phase 4/6 way TPN MCB DB 4/6 ways in each phase Percentage tripping requirement ?
  • 22. TOD Meter Time of Use Meter Peak and Off Peak Slabs Measures When Energy is Consumed How much Energy is Consumed
  • 23. CASE STUDY Avees Food Products, Pulincunnoo, Aleppy Washing Powdering Roasting Grading Packing Load Requirement 290.75 HP 14.7 kW 80 kVAr
  • 26. CONCLUSION HT wiring Design and Standards is familiarized Workflow and Procedures are familiarized Techniques like cable glanding and termination are familiarized AUTOCADD electrical drawings are familiarized
  • 27. THANK YOU ALL VERY MUCH