This document contains notes and details related to utility work for a proposed development project. It includes notes on sanitary sewer lines and manholes, water lines of various sizes, gas and electrical utilities, and callouts for specific items needed like water meters and backflow preventers. Plan views show the proposed utility layout with manholes, lines, and connections labeled. Profile views graphically depict elevations and slopes of sanitary sewer lines. The contractor is responsible for verifying existing utilities, complying with all specifications, and coordinating work with the relevant utility authorities and companies.
1 of 1
Download to read offline
More Related Content
15RDM01-2016-Academy Utility Plan
1. ONLYONLY
ONLY
ONLYONLY
ONLYONLY
ONLY
ONLY
ONLY
ONLY ONLY ONLY
TPED
CO
COCO
CO
CO
CO
CO
CO
CO
CO
CO
CO
CO
CO
CO
CO
SANITARY SEWER MANHOLE
SANITARY SEWER MANHOLE
SANITARY SEWER MANHOLE
SANITARY SEWER MANHOLE
SANITARY SEWER MANHOLE
SANITARY SEWER MANHOLE
SANITARY SEWER MANHOLE
SANITARY SEWER MANHOLE
SANITARY SEWER MANHOLE
LEEMANFERRYRD.SW.
SERVICEROAD
RIGHT-OF-WAY
DEEDBOOK197PAGE572
DEED BOOK 322 PAGE 425
DEED BOOK 197 PAGE 572
RIGHT-OF-WAY
DRAKE AVE.
Sign
T
U.S.231-MEMORIALPARKWAY
PROPOSED FINISH FLOOR 597.20
PROPOSED FINISH FLOOR 597.20
6"
1-1/2"
2"
8"
1-1/2"
G
G
VAN VAN
VAN
VAN
YIELD
YIELD
YIELD
YIELD
CCCC
CCCC
SANITARY SEWER MANHOLE
75 LF-10" RD
T
6"
8"
8"
8"
SANITARY SEWER MANHOLE
SANITARY SEWER MANHOLE
AL.HWY53
CL
CL
STATEROW
STATEROW
0+00 0+50 1+00 1+50 2+00 2+50
570
580
590
600
620
610
570
580
590
600
620
610
STATION-0+00.00(EXISTINGM.H.)
596.00
595.94
594.98
594.96
595.43
586.57
586.64
586.71
586.87
587.02
8"WATER
GASLINE
6"WATER
3"WATER
RIMEL=597.25(ADJUSTRIMEL.)
0+00 0+50 1+00
570
580
590
600
620
610
STATION-0+00.00MANHOLE595.50
595.66
588.33
589.90
1-1/2"WATER
8"WATER
MANHOLE
RIMEL=595.40
INVIN=590.00(6"N)
INVIN=590.00(6"SE)
INVOUT=589.90
RIMEL=595.00
STATION-0+50.00
RIMEL=594.70
INVIN=587.12
INVOUT=587.04
RIMEL=595.00
INVIN=586.98
INVOUT=586.90
STATION-2+16.69-MANHOLE
STATION-1+72.21-MANHOLE
RIMEL=594.80
INVIN=586.82
INVIN=588.00(6"LATERAL)
INVOUT=586.74
STATION-1+18.30-MANHOLE
INVIN=586.57
INVOUT=586.47
50.00LF 8IN of
D.I.P.at 2.0%44.48LF 18IN of
D.I.P.at 0.14%
53.91LF 18IN of
D.I.P.at 0.14%
118.30LF 18IN of
D.I.P.at 0.14%
18" RCP
INVIN=588.33(NEXISTING)
INVIN=588.90
INVOUT=588.33(S)(EEXISTING)
EXISTING PYLON SIGN
LOCATION
0 40 80 120
X:2015Projects15rdm01-AcademySports_Huntsville,ALEngineeringConstructionDocuments15RDM01-2016-08-22REV5.DWGSep29,2016-9:39am
PRINTED:9/29/2016@9:39AM
CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS
FOR EXACT LOCATION AND DIMENSIONS OF SLOPED
PAVING, EXIT PORCHES, RAMPS AND TRUCK DOCKS,
PRECISE BUILDING DIMENSIONS AND EXACT UTILITY
ENTRANCE LOCATIONS.
NOTES:
1. REFER TO ARCHITECT PLAN FOR ALL OUTSIDE LIGHTING ELECTRICAL.
2. ALL WORK WITHIN COUNTY AND CITY ROW's SHALL BE IN ACCORDANCE WITH ALABAMA DEPARTMENT
OF TRANSPORTATION.
NOTE:
CONTRACTOR SHALL COORDINATE ALL PROPOSED
ON-SITE CONDUIT ROUTING FOR TELEPHONE,
POWER AND CABLE TV SERVICE WITH THE UTILITY
COMPANIES. CONTRACTOR SHALL BE
RESPONSIBLE FOR INSTALLING ANY
APPURTENANCES THAT ARE REQUIRED.
R
Know what's below
Call before you dig
19. REFER TO BUILDING PLANS FOR SITE LIGHTING ELECTRICAL PLAN.
20. PIV LOCATED IN BUILDING RISER ROOM WITH ACCESS ON OUTSIDE WALL.
UTILITY NOTES
1. ALL FILL MATERIAL IS TO BE IN PLACE, AND COMPACTED BEFORE INSTALLATION OF PROPOSED
UTILITIES.
2. CONTRACTOR SHALL NOTIFY THE UTILITY AUTHORITIES INSPECTORS 72 HOURS BEFORE
CONNECTING TO ANY EXISTING LINE.
3. SANITARY SEWER PIPE SHALL BE AS FOLLOWS:
-6" SHALL BE DUCTILE IRON PIPE MINIMUM PRESSURE CLASS 350 (INSIDE EASEMENT)
-4" SHALL BE DUCTILE IRON PIPE MINIMUM PRESSURE CLASS 350. (INSIDE EASEMENT)
ALL LATERALS OUTSIDE EASEMENT OR R.O.W. MAY BE PVC.
5. MINIMUM TRENCH WIDTH SHALL BE 2 FEET.
6. ALL WATER JOINTS ARE TO BE MECHANICAL JOINTS WITH THRUST BLOCKING AS CALLED OUT IN
SPECIFICATIONS.
7. ALL UTILITIES SHOULD BE KEPT TEN (10') APART (PARALLEL) OR WHEN CROSSING 18" VERTICAL
CLEARANCE (OUTSIDE EDGE OF PIPE TO OUTSIDE EDGE OF PIPE).
8. CONTRACTOR SHALL MAINTAIN A MINIMUM OF 4'-0" COVER ON ALL WATERLINES.
9. IN THE EVENT OF A VERTICAL CONFLICT BETWEEN WATER LINES, SANITARY LINES, STORM LINES
AND GAS LINES (EXISTING AND PROPOSED), THE SANITARY LINE SHALL BE DUCTILE IRON PIPE
WITH MECHANICAL JOINTS AT LEAST 10 FEET ON BOTH SIDES OF CROSSING, THE WATER LINE
SHALL HAVE MECHANICAL JOINTS WITH APPROPRIATE THRUST BLOCKING AS REQUIRED TO
PROVIDE A MINIMUM OF 18" CLEARANCE, MEETING REQUIREMENTS OF ANSI A21.10 OR ANSI 21.11
(AWWA C-151) (CLASS 50).
10. LINES UNDERGROUND SHALL BE INSTALLED, INSPECTED AND APPROVED BEFORE BACKFILLING.
BY THIRD PARTY INSPECTOR HIRED BY OWNER.
11. TOPS OF EXISTING MANHOLES SHALL BE RAISED OR LOWERED AS NECESSARY TO BE FLUSH WITH
PROPOSED PAVEMENT ELEVATIONS, AND TO BE ONE FOOT ABOVE FINISHED GROUND ELEVATIONS
WITH WATER TIGHT LIDS.
12. ALL CONCRETE FOR ENCASEMENTS SHALL HAVE A MINIMUM 28 DAY COMPRESSION
STRENGTH AT 3000 P.S.I.
13. EXISTING UTILITIES SHALL BE VERIFIED IN FIELD PRIOR TO INSTALLATION OF ANY NEW LINES.
14. REFER TO INTERIOR PLUMBING DRAWINGS FOR TIE-IN OF ALL UTILITIES.
15. CONTRACTOR IS RESPONSIBLE FOR COMPLYING TO THE SPECIFICATIONS OF THE LOCAL
AUTHORITIES WITH REGARDS TO MATERIALS AND INSTALLATION OF THE WATER AND SEWER
LINES.
16. THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF
EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS
UTILITY COMPANIES, AND WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE
INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR
MUST CALL THE APPROPRIATE UTILITY COMPANIES AT LEAST 72 HOURS BEFORE ANY
EXCAVATION TO REQUEST EXACT FIELD LOCATION OF UTILITIES. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT
WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS.
17. CONTRACTOR IS RESPONSIBLE FOR ALL NECESSARY INSPECTIONS AND/OR CERTIFICATIONS
REQUIRED BY CODES AND/OR UTILITY SERVICE COMPANIES. THIS AND THE FINAL CONNECTIONS
OF THE SERVICE SHALL BE COMPLETED 30 DAYS PRIOR TO STORE POSSESSION.
18. CONTRACTOR SHALL COORDINATE WITH ALL UTILITY COMPANIES FOR INSTALLATION
REQUIREMENTS AND SPECIFICATIONS.
4. WATER LINES SHALL BE AS FOLLOWS:
-3" AND GRATER MAINS SHALL BE DUCTILE IRON PIPE PER HUNTSVILLE UTILITIES STANDARD
SPECIFICATIONS
-SMALLER THAN 3" SHALL BE COPPER PIPE PER HUNTSVILLE UTILITIES STANDARD
SPECIFICATIONS.
8. CONTRACTOR SHALL MAINTAIN A MINIMUM OF 3'-0" COVER ON ALL SANITARY SEWER LINES.
A
B
WATER MAIN TAP BY WATER COMPANY.
FDC AND CHECK VALVE REQ'D.
C
2" WATER METER FOR IRRIGATION PER WATER COMPANY SPECIFICATIONS REQ'D.
BY HUNTSVILLE UTILITIES
D
E
F CORPORATE STOP BY HUNTSVILLE UTILITIES.
G
H
THRUST BLOCK REQ'D PER WATER COMPANY SPECIFICATIONS, TYPICAL.
I
RELOCATE EXISTING FIRE HYDRANT
J
K
1" PVC CONDUIT WITH PULL STRINGS FOR TAMPER SWITCH FOR FIRE LINE REQ'D.
P
CLEANOUT REQ'D.
OMIT
V
2-5" PVC UNDERGROUND CONDUIT WITH PULL ROPES FOR UNDERGROUND
ELECTRICAL PRIMARY LINES REQ'D. CONTRACTOR SHALL COORDINATE WITH THE
ELECTRIC COMPANY FOR ALL REQUIREMENTS AND SPECIFICATIONS.
2" WATER METER AND 2" REDUCED PRESSURE TYPE RPZ BACKFLOW PREVENTER
PER WATER COMPANY SPECIFICATIONS REQ'D. BY HUNTSVILLE UTILITIES
6" PVC SANITARY SEWER LATERAL @ 1.0% MINIMUM GRADE REQ'D. ALL LATERAL
CONNECTIONS MADE AT MANHOLES SHALL BE MADE WITH THE INVERT OF THE
LATERAL CONNECTION EQUAL TO THE CROWN OF THE EXISTING (DOWNSTREAM)
SEWER MAIN LINE.
8" DOUBLE DETECTOR CHECK IN ONE VAULT.
Y
GAS METER AND SERVICE LINE BY GAS COMPANY. CONTRACTOR SHALL PROVIDE
BOLLARD PROTECTION AS REQ'D BY GAS COMPANY.
A
A
C
E
F
G
H
H
APROX 85' NORTH
OF SITE
H
L 8" DIP WATER LINE
L
L
M 3" DIP WATER LINE
N 2" COPPER WATER LINE
O 1 1/2" COPPER WATER LINE
M
N
O
P
P
J
Q
SANITARY MANHOLE (REPLACE EXISTING MANHOLE) REQ'D.
Q
P
R
R
SANITARY MANHOLE REQ'D.
S
SANITARY MANHOLE REQ'D.
PLAN STA.=1+18.30
SEE SANITARY SEWER LINE "A" PROFILE FOR DETAIL
S
T OMIT
V
V
W
SANITARY MANHOLE REQ'D.
PLAN STA.=0+00
SEE SANITARY SEWER LINE "B" PROFILE FOR DETAIL
ADJUST TOP FINISHED EL.=595.00 (CONSTRUCT ECCENTRIC MANHOLE LID)
W
X
X
SANITARY MANHOLE REQ'D.
PLAN STA.=0+50.00
SEE SANITARY SEWER LINE "B" PROFILE FOR DETAIL
Y
Y
Z 18" DIP SANITARY SEWER LINE - SEE SANITARY SEWER LINE "A" PROFILE
Z
15'
15'
10'
NOTE:
CONTRACTOR SHALL COORDINATE WITH CITY OF
HUNTSVILLE FOR MAINTAINING THE EXISTING
SEWER LINE OPEN BY PUMPING ON SITE WHILE
CONSTRUCTION OF NEW SEWER LINE FOR
PROJECT TILL RECONNECTION TO EXISTING LINE.
O
PROFESSIONAL
No. 17679
E
N
G I N EER
D
E
RETSI
G
E
R
QRS
U
SANITARY MANHOLE (EXISTING)
PLAN STA.=0+00
SEE SANITARY SEWER LINE "A" PROFILE FOR DETAIL
U
P
INV. 591.00
INV. 591.00
INV. 589.00
H
APROX 74' NORTH
OF SITE
X
W
aa
aa 18" DIP SANITARY SEWER LINE - SEE SANITARY SEWER LINE "B" PROFILE
K
bb
bb EXISTING SANITARY SEWER MANHOLE - RAISE TOP 593.50 EL.
cc EXISTING SANITARY SEWER MANHOLE - RAISE TOP 595.20 EL.
dd EXISTING SANITARY SEWER MANHOLE - RAISE TOP 595.66 EL.
cc
dd
G
M
L
U
K
K
PIV LOCATION
PIV LOCATION
ee FIRE SUPPRESSION SYSTEM PIPING ENTRY REQ'D. - SEE DETAIL
ee
ee
ff BORE LEEMAN FERRY RD. REQUIRED.
ff
2 WAY REQUIRED
B
D
gg 2" to 3" EXPANSION REQUIRED.
gg
D
hh POLE MOUNTED TRANSFORMER REQUIRED.
5
5
5
NOTE: WORK BY CITY
NOTE: WORK BY CITY
6#RFI4RELOCATELIGHTPOLE
7
7REVISEDSERVICEROADACCESSDRIVESPERALDOTCOMMENTS9-09-16