The document discusses various fuel maintenance systems from Algae-X that are designed to filter and clean fuel tanks. It provides specifications for stationary and mobile systems ranging from 3 to 25 gallons per minute that can be used to treat fuel tanks from less than 200 gallons to over 50,000 gallons in size. Key components and control features are described to optimize fuel quality, ensure safety, and provide reliable emergency power.
This document provides specifications for a Yanmar 4LHA-HTP series marine diesel engine. It is a 4-stroke, turbocharged inline 4-cylinder engine with a displacement of 3.455 liters that produces 118 kW at 3300 rpm. It has a freshwater cooling system and enclosed forced lubrication system. The document also lists optional equipment available and details performance curves showing output, torque, fuel consumption, and propeller performance. Dimensions and specifications for compatible marine gearboxes are also provided.
Vertical multistage fire pump catalogue-60HZAndy Chen
油
Vertical multistage pump is always used for fire fighting as jockey pump, for more details, pls check http://www.firepump.cc/product/XBD-CDL-jockey-pump.html
- Fire pumps are centrifugal pumps selected to operate between 90-140% of rated capacity and less than 150% to avoid overpressure.
- Pump rooms require 1-hour fire rated separation, emergency lighting, ventilation, and drainage.
- Suction and discharge piping must be sized properly and have the correct fittings like gauges, valves, and relief valves. Jockey pumps maintain system pressure.
- Electric and diesel fire pump controllers prioritize system operation over equipment protection to ensure reliable fire suppression.
This document provides an electrical circuit diagram and descriptions for a Cummins ISB CM2150 diesel engine from 2007-2009. It includes:
1) A key listing abbreviations for wire colors and component names/numbers.
2) A multi-page diagram showing engine sensors, actuators and their electrical connections to the ECM and vehicle wiring.
3) Pinouts and descriptions for the ECM and other connectors.
The diagram provides technicians with information to trace circuitry and diagnose electrical issues. Abbreviations standardize the representation of colors for consistent identification.
Nfpa20 standard for the installation of stationary pumps for fire protection ...Bowen Ngo
油
This document summarizes the key requirements and guidelines from NFPA20 regarding fire pump installation and operation. It outlines the purpose of fire pumps to provide adequate water supply for sprinklers and standpipes. It describes common pump types like horizontal split case, vertical inline, end suction, and vertical turbine. Guidelines are provided for pump sizing within 90-150% of rated capacity. Requirements are listed for accessories like gauges, valves, relief valves and fittings. The roles of jockey pumps and pressure maintenance are explained. Operation parameters like start and stop pressures are also summarized.
This document provides an overview of sanitation systems and pump parts for boats, including:
- VacuFlush toilet systems with models ranging from small boat toilets to full-size models, along with vacuum generators, tanks, pumps, and accessories.
- SeaLand/VacuFlush macerator toilets in the 8100 and 8600 series with details on features like flush options and dimensions.
- Shower, sink, and faucet products like pumps, fittings, and accessories for plumbing various fixtures.
The document is organized by product category and lists specific models and parts with descriptions, voltages, and other technical specifications. It provides a comprehensive listing of sanitation and pumping
This document discusses variable speed fire pump controllers. It covers the components and operation of variable frequency drives (VFDs) and the requirements for a fire pump controller system using a VFD. Key points include an overview of VFD elements and operation, requirements for the controller system including isolation contactors and pressure monitoring, considerations for motor starting characteristics and coordination, and design factors such as cooling and pollution rating. Application-specific topics like hydraulic system tuning are also addressed.
This document provides technical specifications and operating details for various Hyundai transaxle models, including the M5EF2, A4CF0, M5CF1, and A4AF3. It describes the main features of each model such as structure, gear ratios, clutch and brake components. It also provides details on solenoid valve operation for shifting and failure modes which result in the transmission defaulting to 3rd gear. The document aims to communicate the key technical details and functions of Hyundai automatic transaxle systems to transmission engineers.
Jual,Harga,Distributor Water Heater Pemanas Air Ariston Toko Jakarta,Bekasi,Tangerang Electrik Harga Murah Ekonomis Bergaransi Cv Fikri Mandiri Jaya 082113812149
This document discusses the benefits of variable speed fire pump controllers compared to conventional controllers. Variable speed controllers can maintain a constant system pressure without the need for pressure reducing valves (PRVs) by adjusting the pump speed. This allows taller buildings to be designed without PRVs, saving significant costs. It also improves reliability by having redundant control circuits. While conventional controllers require PRVs for most floors in a 12-story building example, incurring high costs, a variable speed controller can maintain safe pressures on all floors without PRVs.
This document discusses NFPA20, which establishes standards for stationary fire pumps. It covers the purpose of fire pumps in supplying adequate water for fire protection systems. Fire pumps must be listed by authorities and sized according to NFPA standards. The document discusses various types of fire pumps and their applications. It also covers requirements for accessories like gauges, valves, and relief valves. Diesel and electric fire pump controllers are addressed, including their functions, starting methods, and alarm capabilities. Pump maintenance and testing procedures are also summarized.
The document discusses advances in fan coil unit technology and controls presented by Mick Holland. It provides an overview of Ability Projects, a supplier of fan coil units, and their product ranges. It then covers EC motors, pressure independent control valves, and modern controller capabilities for fan coil units. The Matrix range is introduced as a fully packaged fan coil unit with smart pod fans, individual duct pressures, and no need for volume control dampers. Benefits of variable air volume control strategies using the Matrix are discussed.
OBD2 Powertrain Code List (P1000- P2099)Tim Miller
油
Check the OBD2 code list (P1000 - P2009) to find out what the codes mean on your car.
>> NEXT STEP: https://www.obdadvisor.com/codes/
Visit our site, and type the code in the search box. You will get more information about the code including causes, symptoms, fixes, and repair costs.
Reading and clearing the codes will become easier with a scan tool.
>> READ MORE: https://www.obdadvisor.com/best-obd2-scanner-review/
This article shows a helpful in-depth review of the 9 best OBD2 scan tools from me, an experienced auto mechanic who has used and tested all of them.
This document provides specifications for a firefighting deluge valve. It includes:
- Details on the operating conditions, approvals, materials, and connections for the valve.
- Descriptions of the basic trim, dry pilot trim (pneumatic release), wet pilot trim (hydraulic release), electric release trim, and test and alarm trim options.
- Instructions for installation, operation, testing, maintenance and troubleshooting of the deluge valve system.
- Dimensional drawings, part lists, and model information for the deluge valve.
The document provides information on the fuel storage and distribution system of the Boeing 747-400 aircraft. It describes the locations and capacities of the main fuel tanks and describes the functions of the fuel pumps, valves, and controls. It also outlines different indications that appear on the fuel system displays under various flight conditions and fuel levels.
www.Lucky-Bet.site => Bet on Sports - 50% Deposit Bonus
www.Lucky-Bet.site/casino => Online Casino - 5000$ Welcome Bonus
www.Lucky-Bet.site/lotto247 => Lotto247 - Win Big, Live Free
www.Lucky-Bet.site/eurobet => Best European Bookmaker
www.earnperhit.com/essay => Professional academic writing
Key Characteristics and Requirements of Diesel Fire Pump Engines
This document provides specifications for the PW20 and PW20eR dishwashers. It includes:
- Standard features like wash cycles, water usage, tank capacity, and dimensions.
- Connection information for electrical, plumbing, and chemicals.
- Rack capacities per hour for each model.
- Construction details about the tank, doors, pumps, and other components.
- Operation details for the wash, rinse, and sanitization cycles.
The document provides specifications for the PHWPortable, Electric-Powered, Diesel-Heated, Hot Water Pressure Washer. It can produce up to 4.8 GPM at 3000 PSI. It features a Landa pump with a 7-year warranty and patented Cool Bypass system. It has optional remote control, auto start/stop, and is designed for durability, safety, and ease of maintenance.
Maintenance instructions for power transformersLucian Lazar
油
This document provides maintenance instructions and schedules for power transformers. It lists items to inspect on hourly, daily, quarterly, half-yearly, yearly, and 5-10 yearly schedules. These include ambient temperature, winding temperature, oil temperature, load, voltage, oil levels, bushings, breather, cooler fan operation, gasket joints, relays, painting, and earth resistance. It describes what to check for each item and the required actions if inspections show unsatisfactory conditions, such as low oil levels, cracks, rust, or abnormal operation. The goal is to ensure temperatures, oil quality, components, and performance remain within specified limits through regular inspections and maintenance.
Daikin simple self diagnosis by malfunction code p1-6-errorcodeCurteanuCostin
油
The document provides a summary of malfunction codes and their meanings for various HVAC systems, including air conditioners, heat reclaim ventilators, chillers, and fan coil units. It lists specific malfunction codes for issues like malfunctions of indoor unit PCBs, freezing protection failures, thermistor malfunctions, high/low pressure switch activations, compressor overheating/overcurrent, and more. The document also identifies the supposed causes and applicable device types for each malfunction code.
Toyota 30 5 fbc18 battery forklift service repair manualfhsjekdmme
油
This document provides service information for the Toyota Battery Forklift 5FBC13 - 30 Series. It contains sections on the battery, control circuit, electrical system troubleshooting, and other major vehicle systems. The foreword states that the manual covers service procedures for the specified forklift models as of November 1991 and notes that actual vehicles may differ from the descriptions due to design changes. It also directs the user to Toyota publications for any updates to specifications or procedures.
The document provides a catalog for electric equipment including contactors, overload relays, starters, and accessories. It includes:
- Descriptions and specifications for various contactors, overload relays, starters, and accessories ranging from mini contactors up to 800A.
- Numbering systems for identifying part types and specifications like voltage, current rating, and number of poles.
- Layout diagrams showing common configurations for mounting contactors and accessories.
- Technical information on features of thermal and electronic overload relays, digital motor protection relays, and environmental compliance.
- Quick selection tables to choose the right contactor or overload relay for an application.
The Portapump is a portable fuel pump designed to rapidly fuel or defuel aircraft and vehicles using jet fuel or diesel. It uses a powerful 24-28 volt motor and high-speed pump housed in a stainless steel frame. Hoses and fittings are quick-release to allow fast connections. The pump can filter fuel to 3 microns and remove water down to 2 parts per million, allowing safe reuse of fuel. Controls include LED indicators to show pump status and an automatic shut-off when fueling is complete. The Portapump is lightweight at 27.5kg and can be easily transported.
The document discusses the basic components of continuous renal replacement therapy (CRRT), including hemofilters, solutions, vascular access points, anticoagulation methods, and blood warmers. It provides details on the PrismaFlex CRRT system, including its disposable set, solutions, and flow control and fluid control units. The flow control unit contains pumps, pinch valves, and a patented deaeration chamber for air removal. The fluid control unit uses several scales to measure effluent, replacement, dialysate, and pre-blood pump fluids.
The document describes transportable fire pumps, including:
Suction
- The Dependapower DPGOU 6040 CAT-R, a trailer-mounted pump with a 6,000 gpm rating powered by a Caterpillar diesel engine. It has a triple axle trailer, 14" suction manifold, and 10" discharge manifold.
- A Patterson/Caterpillar 4,000 gpm pump on a dual axle trailer with a 500HP Caterpillar diesel, 12" suction manifold, and 10" discharge manifold.
- A new lo-pressure/hi-volume N-Hancer submersible pump that can provide up to 9,000 gpm and be
The document provides information on MHC-3000 series ultrasonic flow meters, including four models (MHC-3000B, MHC-3000G, MHC-3000H, MHC-3000P). It describes the key features and specifications of each model such as type, principle, functions, portability, transducers, power supply, outputs, applications, and optional components. Various transducer options are also detailed including specifications for plug-in, clamp-on, and inline sensor types. Ordering information is provided at the end to customize orders based on selected components.
This document provides technical specifications and operating details for various Hyundai transaxle models, including the M5EF2, A4CF0, M5CF1, and A4AF3. It describes the main features of each model such as structure, gear ratios, clutch and brake components. It also provides details on solenoid valve operation for shifting and failure modes which result in the transmission defaulting to 3rd gear. The document aims to communicate the key technical details and functions of Hyundai automatic transaxle systems to transmission engineers.
Jual,Harga,Distributor Water Heater Pemanas Air Ariston Toko Jakarta,Bekasi,Tangerang Electrik Harga Murah Ekonomis Bergaransi Cv Fikri Mandiri Jaya 082113812149
This document discusses the benefits of variable speed fire pump controllers compared to conventional controllers. Variable speed controllers can maintain a constant system pressure without the need for pressure reducing valves (PRVs) by adjusting the pump speed. This allows taller buildings to be designed without PRVs, saving significant costs. It also improves reliability by having redundant control circuits. While conventional controllers require PRVs for most floors in a 12-story building example, incurring high costs, a variable speed controller can maintain safe pressures on all floors without PRVs.
This document discusses NFPA20, which establishes standards for stationary fire pumps. It covers the purpose of fire pumps in supplying adequate water for fire protection systems. Fire pumps must be listed by authorities and sized according to NFPA standards. The document discusses various types of fire pumps and their applications. It also covers requirements for accessories like gauges, valves, and relief valves. Diesel and electric fire pump controllers are addressed, including their functions, starting methods, and alarm capabilities. Pump maintenance and testing procedures are also summarized.
The document discusses advances in fan coil unit technology and controls presented by Mick Holland. It provides an overview of Ability Projects, a supplier of fan coil units, and their product ranges. It then covers EC motors, pressure independent control valves, and modern controller capabilities for fan coil units. The Matrix range is introduced as a fully packaged fan coil unit with smart pod fans, individual duct pressures, and no need for volume control dampers. Benefits of variable air volume control strategies using the Matrix are discussed.
OBD2 Powertrain Code List (P1000- P2099)Tim Miller
油
Check the OBD2 code list (P1000 - P2009) to find out what the codes mean on your car.
>> NEXT STEP: https://www.obdadvisor.com/codes/
Visit our site, and type the code in the search box. You will get more information about the code including causes, symptoms, fixes, and repair costs.
Reading and clearing the codes will become easier with a scan tool.
>> READ MORE: https://www.obdadvisor.com/best-obd2-scanner-review/
This article shows a helpful in-depth review of the 9 best OBD2 scan tools from me, an experienced auto mechanic who has used and tested all of them.
This document provides specifications for a firefighting deluge valve. It includes:
- Details on the operating conditions, approvals, materials, and connections for the valve.
- Descriptions of the basic trim, dry pilot trim (pneumatic release), wet pilot trim (hydraulic release), electric release trim, and test and alarm trim options.
- Instructions for installation, operation, testing, maintenance and troubleshooting of the deluge valve system.
- Dimensional drawings, part lists, and model information for the deluge valve.
The document provides information on the fuel storage and distribution system of the Boeing 747-400 aircraft. It describes the locations and capacities of the main fuel tanks and describes the functions of the fuel pumps, valves, and controls. It also outlines different indications that appear on the fuel system displays under various flight conditions and fuel levels.
www.Lucky-Bet.site => Bet on Sports - 50% Deposit Bonus
www.Lucky-Bet.site/casino => Online Casino - 5000$ Welcome Bonus
www.Lucky-Bet.site/lotto247 => Lotto247 - Win Big, Live Free
www.Lucky-Bet.site/eurobet => Best European Bookmaker
www.earnperhit.com/essay => Professional academic writing
Key Characteristics and Requirements of Diesel Fire Pump Engines
This document provides specifications for the PW20 and PW20eR dishwashers. It includes:
- Standard features like wash cycles, water usage, tank capacity, and dimensions.
- Connection information for electrical, plumbing, and chemicals.
- Rack capacities per hour for each model.
- Construction details about the tank, doors, pumps, and other components.
- Operation details for the wash, rinse, and sanitization cycles.
The document provides specifications for the PHWPortable, Electric-Powered, Diesel-Heated, Hot Water Pressure Washer. It can produce up to 4.8 GPM at 3000 PSI. It features a Landa pump with a 7-year warranty and patented Cool Bypass system. It has optional remote control, auto start/stop, and is designed for durability, safety, and ease of maintenance.
Maintenance instructions for power transformersLucian Lazar
油
This document provides maintenance instructions and schedules for power transformers. It lists items to inspect on hourly, daily, quarterly, half-yearly, yearly, and 5-10 yearly schedules. These include ambient temperature, winding temperature, oil temperature, load, voltage, oil levels, bushings, breather, cooler fan operation, gasket joints, relays, painting, and earth resistance. It describes what to check for each item and the required actions if inspections show unsatisfactory conditions, such as low oil levels, cracks, rust, or abnormal operation. The goal is to ensure temperatures, oil quality, components, and performance remain within specified limits through regular inspections and maintenance.
Daikin simple self diagnosis by malfunction code p1-6-errorcodeCurteanuCostin
油
The document provides a summary of malfunction codes and their meanings for various HVAC systems, including air conditioners, heat reclaim ventilators, chillers, and fan coil units. It lists specific malfunction codes for issues like malfunctions of indoor unit PCBs, freezing protection failures, thermistor malfunctions, high/low pressure switch activations, compressor overheating/overcurrent, and more. The document also identifies the supposed causes and applicable device types for each malfunction code.
Toyota 30 5 fbc18 battery forklift service repair manualfhsjekdmme
油
This document provides service information for the Toyota Battery Forklift 5FBC13 - 30 Series. It contains sections on the battery, control circuit, electrical system troubleshooting, and other major vehicle systems. The foreword states that the manual covers service procedures for the specified forklift models as of November 1991 and notes that actual vehicles may differ from the descriptions due to design changes. It also directs the user to Toyota publications for any updates to specifications or procedures.
The document provides a catalog for electric equipment including contactors, overload relays, starters, and accessories. It includes:
- Descriptions and specifications for various contactors, overload relays, starters, and accessories ranging from mini contactors up to 800A.
- Numbering systems for identifying part types and specifications like voltage, current rating, and number of poles.
- Layout diagrams showing common configurations for mounting contactors and accessories.
- Technical information on features of thermal and electronic overload relays, digital motor protection relays, and environmental compliance.
- Quick selection tables to choose the right contactor or overload relay for an application.
The Portapump is a portable fuel pump designed to rapidly fuel or defuel aircraft and vehicles using jet fuel or diesel. It uses a powerful 24-28 volt motor and high-speed pump housed in a stainless steel frame. Hoses and fittings are quick-release to allow fast connections. The pump can filter fuel to 3 microns and remove water down to 2 parts per million, allowing safe reuse of fuel. Controls include LED indicators to show pump status and an automatic shut-off when fueling is complete. The Portapump is lightweight at 27.5kg and can be easily transported.
The document discusses the basic components of continuous renal replacement therapy (CRRT), including hemofilters, solutions, vascular access points, anticoagulation methods, and blood warmers. It provides details on the PrismaFlex CRRT system, including its disposable set, solutions, and flow control and fluid control units. The flow control unit contains pumps, pinch valves, and a patented deaeration chamber for air removal. The fluid control unit uses several scales to measure effluent, replacement, dialysate, and pre-blood pump fluids.
The document describes transportable fire pumps, including:
Suction
- The Dependapower DPGOU 6040 CAT-R, a trailer-mounted pump with a 6,000 gpm rating powered by a Caterpillar diesel engine. It has a triple axle trailer, 14" suction manifold, and 10" discharge manifold.
- A Patterson/Caterpillar 4,000 gpm pump on a dual axle trailer with a 500HP Caterpillar diesel, 12" suction manifold, and 10" discharge manifold.
- A new lo-pressure/hi-volume N-Hancer submersible pump that can provide up to 9,000 gpm and be
The document provides information on MHC-3000 series ultrasonic flow meters, including four models (MHC-3000B, MHC-3000G, MHC-3000H, MHC-3000P). It describes the key features and specifications of each model such as type, principle, functions, portability, transducers, power supply, outputs, applications, and optional components. Various transducer options are also detailed including specifications for plug-in, clamp-on, and inline sensor types. Ordering information is provided at the end to customize orders based on selected components.
The Grundfos DW pumps form part of a complete range of wastewater and sewage
handling products. Like all Grundfos products the DW pump series offer unique cus-
tomer benefits, making them the natural choice for any job where raw water needs to
be pumped - whether from construction sites, mining pits, excavations, or flooded base-
ments, etc.
The document describes variable displacement vane pumps with hydraulic pressure compensation. It provides details on pump features such as flange dimensions, pressure and flow ratings, and technical specifications. It also discusses combining multiple pumps together using coupling units and controlling them with a single pressure control device to achieve higher displacements. Dimensions for combined pump units are given.
Insertion turbine flow meters measure flow of liquid, gas, and
steam by detecting the frequency of rotation of the turbine blades. The frequency of turbine rotation is directly proportional to the flow velocity. Insertion turbine flow meters measure flow by detecting the local velocity within the pipe. The fluid velocity is combined with other parameters to calculate the average pipe velocity and volumetric flow rate.
Buy JCB JS205LC Tracked Excavator in India - JCB Heavy Machineryjcbheavymachinery
油
Buy now JCB JS205LC tracked excavator in India and get yourselves a state-of-the-art excavator made through using advance technology and in terms of reliability and durability the JCB JS205LC tracked excavator comes with Use of robust cast ends and pivot bosses provide strength and durability to boom and arm.
Grindex produces submersible heavy-duty pumps for demanding industries like construction, mining, and tunnels. Their pump line includes drainage pumps from 1.3 to 140 HP and sludge pumps. The document discusses features like built-in motor protection, wear resistance, and easy serviceability that reduce operational costs. It provides specifications for individual pump models ranging from the Minex to the Mega.
Parker Balston is a division of Parker Hannifin, worlds leading diversified manufacturer of motion and control technologies and systems. Balston manufacturers industrial filters and filtration technology, replacement filter elements, compressed air dryers, nitrogen generators, and compressed air microbial detection.
This document provides information on HPLC pumps from Greyhound Chromatography, including specifications and ordering details for various pump models. It describes pumps for isocratic and gradient applications across a range of flow rates and pressures. Models include single piston and dual piston pumps, as well as constant pressure and high pressure pumps. Replacement parts and accessories are also listed. The document aims to help customers select the appropriate pump for their HPLC system and application needs.
This document provides information about a company called Super Solution including:
1. It offers diversified terminal connection methods for its ACB main circuit to accommodate various installation needs such as horizontal, vertical, front, and mixed connection types.
2. The document describes the external configuration, internal configuration, and terms/components associated with Super Solution's air circuit breakers.
3. Technical specifications and ratings are provided for different ACB types covering rated current, voltage, breaking capacity, dimensions, and more.
Hanyoung participated in the 2013 Korea Machinery Fair held from October 16-19, where they introduced several new products including digital temperature controllers, HMIs, graphic recorders, solid state relays, multi-loop controllers, proximity sensors and photo sensors. Hanyoung's HMI TG series in various screen sizes of 5, 7, 10, 12, 15 inches attracted many visitors and is expected to be a top-selling product. The fair was held at KINTEX and combined several major capital exhibitions, making it Korea's largest exhibition.
Algae x fuel management systems - technical presentation - rev a
1. Optimal Fuel Quality Ensures Safe & Reliable Emergency Power Rev A - 07/2008 Fuel Maintenance Systems
2. Fuel Maintenance System - OVERVIEW * Recommended tank size is a ball park figure. Depending on refuel frequency, consumption, tank access, contamination, etc. and cleaning time this values can be extended / lowered. Larger capacity equipment for higher flow rates available 油 GPM GPH Gal. treated in 8 h Gal. treated in 24 h Gal. treated in 48 h Recommended Tank Size *) Rec. Plumbing / Hose Size Suction Discharge STS 6000-SX 3 180 1440 4320 8640 < 2,000 Gallons 5/8" 1/2" STS 6000-4GPM 4 240 1920 5760 11520 < 4,000 Gallons 3/4" 3/4" STS 6000-4GPM-S 4 240 1920 5760 11520 < 8,000 Gallons 3/4" 3/4" STS 5000-10GPM 10 600 4800 14400 28800 < 20,000 Gallons 1" 1" STS 5000-25GPM 25 1500 12000 36000 72000 > 20,000 Gallons 2" 2" 油 油 油 油 油 油 油 油 油 TK 180 XT 3 180 油 油 油 < 200 Gallons 1/2" 1/2" MTC 500 8 480 3840 11520 < 3,000 Gallons 3/4"(fuel) 1"(oil) 3/4" MTC 1000 15 900 7200 21600 < 5,000 Gallons 1" 1" MTC 3000 26 1560 12480 37440 < 10,000 Gallons 1 1/2" 1 1/4"
3. STS 6000-SX 3 GPM - Completely automated, compact, safe, stand alone, turn-key Algae-X SFC-50 - UL508A listed Smart Filtration Controller Fully automated programmable PLC with alarms and safety switches for pump functions, filter pressure, leak detection and separator water level External alarm indication stack light (beacon) Control / alarm functions on SFC-50 (Indicator lights, PLC text screen, selector switch, reset push button) Options: stainless steel enclosure, flow meter, rotor sight glass, audible alarm
4. STS 6000-SX General Specs Flow rate 3 GPM Tank Size < 2,000 gal Port Size 3/4 NPT Inlet 1/2 NPT outlet Power 110V / 60Hz or 230V / 50Hz Weight ~135 lbs Dim. (HxWxD) 30 x 24 x 10 LG-X Model 500 Filter / Water Sep. 10 or 30 micron Motor 1/3 hp single phase, continuous duty, thermally protected Weatherproof single door wall-mounted enclosure with lockable handles / latches 14-gauge steel construction with continuously welded seams Finished in polyester powder coat Louvered side panels Brackets for wall mounting Literature pocket Stainless steel plumbing * Not for use with fluids that have a flash point below 100 F (e.g. Gasoline, Alcohol, )
5. STS 6000-S 4GPM Completely automated, safe, stand alone, turn key Three- or four-stage water removal and particulate filtration down to 3 micron Algae-X Smart Filtration Controller UL508A listed Fully automated programmable PLC control with alarms and safety switches for pump functions, filter pressure, leak detection, flow detection and water level in the separator Integrated industrial display and control panel Options: stainless steel enclosure, flow meter, rotor sight glass, audible alarm
6. STS 6000-4GPM(-S) General Specs Flow rate 4 GPM Tank Size < 8,000 gal Port Size 3/4 NPT Power 110V / 60Hz or 230V / 50Hz Weight ~200 lbs Dim. (HxWxD) 36 x 36 x 12 LG-X Model 1500 Primary Filter 10 or 30 micron (optional: 60 micron cleanable stainless steel) Secondary Filter 3 or (10) micron (Water Block) Motor 1/2 hp single phase, continuous duty, thermally protected Weatherproof single door wall-mounted enclosure with lockable handles / latches 14-gauge steel construction with continuously welded seams Finished in polyester powder coat Louvered side panels Brackets for wall mounting Literature pocket Stainless steel plumbing * Not for use with fluids that have a flash point below 100 F (e.g. Gasoline, Alcohol, )
7. STS 6000-4GPM(-S) Control / Alarm Features Pump Control Key Selector Switch: Manual Off Automatic Alarm Reset Push Button Emergency Stop Push Button (Turn to release) Indicator Lights: System Power Pump Running High Vacuum Alarm (Change Primary Filter) High Pressure Alarm (Change Secondary Spin-On Filter) Leak Detection (Float Switch in Spill Tray) High Water Alarm (Drain bowl of primary filter)
10. STS 6000-4GPM(-S) Wiring / Communication Digital Input: External pump shut-down contact Digital Outputs: NO Dry Contact Summary Alarm NO Dry Contact Leak Detection (Pump Running Dry Contact)
11. STS 5000-10GPM General Specs Flow rate 10 GPM Tank Size < 20,000 gal Port Size 1 NPT Power 110V / 60Hz or 230V / 50Hz Weight ~450 lbs Dim. (HxWxD) 42 x 68 x 14 LG-X Model 3000 Primary Filter 10 or 30 micron (optional: 60 micron cleanable stainless steel) Secondary Filter 3 or (10) micron (Water Block) Motor 1 hp single phase, continuous duty, thermally protected Weatherproof double door wall-mounted enclosure with lockable handles / latches 16-gauge steel construction with continuously welded seams Finished in polyester powder coat Louvered side panels Flanges for wall / pedestal mounting Literature pocket * Not for use with fluids that have a flash point below 100 F (e.g. Gasoline, Alcohol, )
12. STS 5000-10GPM Components 1) Fuel Inlet 2) Inlet Ball Valve 3) Primary Filter / Water Separator 4) Vacuum Gauge 5) Drain Valve (push and turn to open) 6) Lid for Primary Filter Replacement 7) Vacuum Switch 8) Water Sensor 9) Priming Tee 10) Gear Pump 11) Motor 12) ALGAE-X速 Magnetic Fuel Conditioner 13) Secondary Filter 14) Pressure Gauge and Pressure Switch 15) Check Valve 16) Outlet Ball Valve 17) Fuel Outlet 18) Pressure Relief Valve 19) Leak Detector in Catch Basin
14. STS 5000-10GPM Wiring / Communication Digital Input (for Auto Mode only): External pump shut-down dry contact Digital Outputs: 4 x Alarm Dry Contacts (NO/NC)
15. STS 5000-25GPM General Specs Flow rate 25 GPM Tank Size < 50,000 gal Port Size 2 NPT Power 460V / 3 / 60Hz Weight ~600 lbs Dim. (HxWxD) 42 x 79 x 14 LG-X Model 3000 Primary Filter 40 Mesh SS strainer Water Separator / Coalescer Secondary Filter 3 or (10) micron (Water Block) 2 pcs. required Motor 2 hp three phase, continuous duty, thermally protected Weatherproof double door wall-mounted enclosure with lockable handles / latches 16-gauge steel construction, continuously welded seams Finished in polyester powder coat Louvered side panels Flanges for wall / pedestal mounting Literature pocket * Not for use with fluids that have a flash point below 100 F (e.g. Gasoline, Alcohol, )
17. STS Installation Located as close as possible to the tank to minimize plumbing run Dedicated pickup and return lines, separated from the fuel lines of the genset and / or other pumps Pickup tube at one end of the tank and a suction pipe as close as possible to the bottom of the tank at the deepest spot. An oversized, low restriction foot valve is recommended to keep the line primed. The return line should be placed at the farthest most point from the pick-up tube A priming-tee should be installed on the highest point of the suction line A backing wrench is required to connect to the provided pipe nipples do not put and stress on plumbing Always comply with all applicable standards, safety guidelines as well as local, state and federal regulations.
19. Redundant, Primary In-line Fuel Filtration Redundant, Switchable, High Capacity Primary Filter/Water Separator Full Flow Rated up to 2000 GPH (single filter) 1HG or less restriction at full flow Single lever to switch between filters under full load for simple, fail-safe and intuitive operation Five separation/filtration stages ensure 99.9% water separation at max flow rate Compact Design No Mess Filter Change with Top Access with very little clearance required Stainless steel, liquid filled vacuum gauges with tell tale finger Push and turn safety drain valve
20. Filter Monitoring System Filter Monitoring System with local alarm display and dry contacts for BAS/BMS Plug & Play connection to Redundant, Duplex Filter System High Water Alarm for Left and Right Filters High Vacuum Alarm (Service Filter) All alarms are locally displayed, as well as provided as N.O./N.C. dry contacts on a terminal block for customer wiring Alarms are latching and need to be reset on local alarm panel with provided reset push button Filter Monitoring System is equipped with power status indicator light Power: 24V DC
21. Mobile Tank Cleaning Systems Delivered complete and ready to go Portable, compact system on handcart Simple operation Restore your fuel instead of disposing it Low operating cost due to low use of consumables Flow rates 3, 8, 15 & 25 GPM MTC 500/1000/3000 TK-180XT
22. CONTACT US ALGAE-X International 5400-1 Division Drive Fort Myers, FL 33905 Tel: 239 690 9589 Toll Free: 877 425 4239 Fax: 239 690 1195 Email: sales@algae-x.net Web: www.algae-x.net
Editor's Notes
#2: Fuel Quality is Key to Peak Engine Performance and Reliability. This presentation is a discussion of fuel, fuel quality issues, and new technologies that can make a major impact on improving fuel quality. Optimizing fuel quality results in improving Engine operating efficiency, Lowering & Maintenance Costs & Downtime, and Reducing Fuel Consumption. Professionals in the business of operating & maintaining diesel equipment know that good quality diesel fuel is better for their engines than bad fuel - - but When will good fuel become bad fuel? What does bad fuel mean in terms of engine performance and maintenance? What can be done to improve and maintain high quality fuel? What is good and what is bad fuel? Our session today will discuss these issues, along with answers to what you can do to improve and manage your fuel systems to minimize fuel related problems and save money for your company and your customers by Lowering overall Operating & Maintenance costs.