Avea® VentilatorDelivering your highest standard of careDelivering your highest standard of care Reginald SamuelSales Consultant Virtus Trading L.L.Cwww.virtusuae.com
Viasys range of Ventilaters Sub Acute CareIMC, ERAdult/Ped. AcuteCareICU, PICUHomeCareNeo Acute CareNICUAveaAveaVelaLTV12003100A (HFOV)3100B (HFOV)SiPAP
Neonatal to AdultVolume 2.0 ml to 2.5 liter - suitable for neonates to adults1 to 150 bpm (neonatal), 1 to 120 bpm (pediatric I adult)Closed loop FiO2Integrated Heliox DeliveryAdvanced Pulmonary Mechanics Volumetric CO2Touch Screen Controls (TTT)Avea® Overview
Closed loop FiO2SpO2FiO2
Current procedure  for SpO2 Control
SpO2FiO2Current procedure  for SpO2 Control
Closed loop FiO2 CLiO
SpO2FiO2Routine (4h)Automated (4h)Closed loop FiO2 CLiO
University of Miami patented / licensed algorithmsAveaLong-life blenderImproves blender longevity and accuracyAccumulator isolation valveImproves responseAdd pulse oximeter module (Masimo)Technology
Avea Final
No need for the user to titrate FiO2Significant 40% work load of the nurses is reduced  SpO2 Leave is well maintained according to the clinician ’s desireNeonate is safe from complications of Hyperoxia affects like Detached RetinaAdvantages of CLiO
Integrated HelioxDeliveryNo need to attach external device to provide Heliox delivery Easy to switch between medical gas and HelioxAvea® automatically sense  which gas control to initiate
To set optimal PEEP only two measurements are requiredTranspulmonary Plateau Pressure (Ptp Plat)Transpulmonary PEEP (Ptp PEEP)Setting optimal ventilatory pressures reduces ventilation daysReducing ventilation days reduces the risk of infectionPlacing an esophageal catheter is as easy as placing a naso-gastric tubeAdvanced Pulmonary MechanicstechnologyTranspulmonary Pressure Monitoring
One of four automated assessment maneuvers for obtaining recruit able lung tissue. Both high and low inflection points are calculated and displayed.PflexAdvanced Mechanics
ARDS and ALI lungs need relatively high levels of PEEPHigh PEEP can have severe effects on:Cardiac OutputPerfusionPerfusion/Ventilation MatchVolumetric Capnography is the ideal tool to monitor:PerfusionVentilationPerfusion/Ventilation MatchDeadspace0.8 ccVolumetric CO2
Advanced mainstream sampling of airway providing following volumetric Capnography featuresEvaluation of changes in anatomic, alveolar and physiologic dead spaceEvaluation of the effectiveness of ventilationMeasurement of C02 elimination / productionEvaluation of EtC02 Trends in ventilationMonitors: End Tidal C02 (ETC02), VC02, VtC02Waveforms & Loops: Capnogram, Single Breath PC02 vs. Vte loopVolumetric CapnographyAdvanced Mechanics
Transpulmonary Pressure (Ptp)Enables the setting of optimal ventilatory pressuresVolumetric Capnography (VCO2)Enables the testing for perfusion/ventilation mismatchONLY the AVEA offers these diagnostics toolsONLY the blood gases value take sep The AVEA brings Ptp and VCO2 togetherAdvanced Mechanics
Display of Rapid Shallow Respiratory Breathing Index(RSBI), Maximum Inspiratory Pressure (MIP), Respiratory Drive (P100), Dynamic Compliance & Resistanceweaning parametersAdvanced Mechanics
24hr trends24hr trends of 54 monitored parameter
Dedicated MonitoringConfigurable monitoring screen allows user to monitor 15 parameter in one screen for 54 monitored parameter
Color Coded Touch Screen User can easily identify patient triggered breaths at a glance
Revolutionary CompressorUnique scroll pump compressor is so small and is built into the AVEA.During power failure the compressor can work on standard internal battery for 30 minutes.This enables the ventilator to be  unplugged and moved with the patient easily.
Heated Expiratory Filter SystemAVEA’s Heated Filter System helps maintain flow sensor performance and helps reduce airborne pathogens in patient’s room, such as SARS, Avian Flu and MRSA.
 The HEPA filtration element filters the expired gas to 0.3 microns. With a 99.999+% bacterial and viral efficiency rating providing the best environment for staff and patients.Single patient use60% lower resistance compared to Pall Microbial Filter Single Piece Combi: No need for current cartridge with Pall Microbial Filter and separate water trapDisposable Expiratory Filter/Water Trap
Volume Controlled VentilationVolume Assist Control (AlC) ModeVolume SIMV ModePressure Support VentilationPressure Assist Control (AlC) ModePressure SIMVAirway Pressure Release Ventilation (APRV I Biphasic/Bilevel/BiPAP)Pressure Regulated Volume Control (PRVC) SIMV ModePressure Regulated Volume Control (PRVC) Assist Control (A/C) ModeTCPL SIMV Mode (time cycle pressure limit)TCPL Assist Control (AlC) ModeNeonatal Nasal nCPAP ModeContinuous Positive Airway Pressure with Pressure Support Ventilation (CPAP/PSV)Apnea Back up VentilationStandbyBreath Types and Modes
CommunicationsAVEA offers a selection of protocols compatible with many patient monitoring and hospital information systems. A VGA output for training and a parallel port for printing
Intuitive Operation & DisplayMode, screen and status indicators are easy to see at a distanceSelectable, full color graphics improve breath phase recognition(Red, Blue & Yellow)Five monitored values are visible to the user at all times: each is selectable from a menu of 54 options The intuitive “touch-turn-touch tm “ design reduces training time and enhances clinician confidence Valuable information is displayed to assist the practitioner with clinical decisions
Patient Safety
Avea Final

More Related Content

Avea Final

  • 1. Avea® VentilatorDelivering your highest standard of careDelivering your highest standard of care Reginald SamuelSales Consultant Virtus Trading L.L.Cwww.virtusuae.com
  • 2. Viasys range of Ventilaters Sub Acute CareIMC, ERAdult/Ped. AcuteCareICU, PICUHomeCareNeo Acute CareNICUAveaAveaVelaLTV12003100A (HFOV)3100B (HFOV)SiPAP
  • 3. Neonatal to AdultVolume 2.0 ml to 2.5 liter - suitable for neonates to adults1 to 150 bpm (neonatal), 1 to 120 bpm (pediatric I adult)Closed loop FiO2Integrated Heliox DeliveryAdvanced Pulmonary Mechanics Volumetric CO2Touch Screen Controls (TTT)Avea® Overview
  • 5. Current procedure for SpO2 Control
  • 6. SpO2FiO2Current procedure for SpO2 Control
  • 9. University of Miami patented / licensed algorithmsAveaLong-life blenderImproves blender longevity and accuracyAccumulator isolation valveImproves responseAdd pulse oximeter module (Masimo)Technology
  • 11. No need for the user to titrate FiO2Significant 40% work load of the nurses is reduced SpO2 Leave is well maintained according to the clinician ’s desireNeonate is safe from complications of Hyperoxia affects like Detached RetinaAdvantages of CLiO
  • 12. Integrated HelioxDeliveryNo need to attach external device to provide Heliox delivery Easy to switch between medical gas and HelioxAvea® automatically sense which gas control to initiate
  • 13. To set optimal PEEP only two measurements are requiredTranspulmonary Plateau Pressure (Ptp Plat)Transpulmonary PEEP (Ptp PEEP)Setting optimal ventilatory pressures reduces ventilation daysReducing ventilation days reduces the risk of infectionPlacing an esophageal catheter is as easy as placing a naso-gastric tubeAdvanced Pulmonary MechanicstechnologyTranspulmonary Pressure Monitoring
  • 14. One of four automated assessment maneuvers for obtaining recruit able lung tissue. Both high and low inflection points are calculated and displayed.PflexAdvanced Mechanics
  • 15. ARDS and ALI lungs need relatively high levels of PEEPHigh PEEP can have severe effects on:Cardiac OutputPerfusionPerfusion/Ventilation MatchVolumetric Capnography is the ideal tool to monitor:PerfusionVentilationPerfusion/Ventilation MatchDeadspace0.8 ccVolumetric CO2
  • 16. Advanced mainstream sampling of airway providing following volumetric Capnography featuresEvaluation of changes in anatomic, alveolar and physiologic dead spaceEvaluation of the effectiveness of ventilationMeasurement of C02 elimination / productionEvaluation of EtC02 Trends in ventilationMonitors: End Tidal C02 (ETC02), VC02, VtC02Waveforms & Loops: Capnogram, Single Breath PC02 vs. Vte loopVolumetric CapnographyAdvanced Mechanics
  • 17. Transpulmonary Pressure (Ptp)Enables the setting of optimal ventilatory pressuresVolumetric Capnography (VCO2)Enables the testing for perfusion/ventilation mismatchONLY the AVEA offers these diagnostics toolsONLY the blood gases value take sep The AVEA brings Ptp and VCO2 togetherAdvanced Mechanics
  • 18. Display of Rapid Shallow Respiratory Breathing Index(RSBI), Maximum Inspiratory Pressure (MIP), Respiratory Drive (P100), Dynamic Compliance & Resistanceweaning parametersAdvanced Mechanics
  • 19. 24hr trends24hr trends of 54 monitored parameter
  • 20. Dedicated MonitoringConfigurable monitoring screen allows user to monitor 15 parameter in one screen for 54 monitored parameter
  • 21. Color Coded Touch Screen User can easily identify patient triggered breaths at a glance
  • 22. Revolutionary CompressorUnique scroll pump compressor is so small and is built into the AVEA.During power failure the compressor can work on standard internal battery for 30 minutes.This enables the ventilator to be unplugged and moved with the patient easily.
  • 23. Heated Expiratory Filter SystemAVEA’s Heated Filter System helps maintain flow sensor performance and helps reduce airborne pathogens in patient’s room, such as SARS, Avian Flu and MRSA.
  • 24. The HEPA filtration element filters the expired gas to 0.3 microns. With a 99.999+% bacterial and viral efficiency rating providing the best environment for staff and patients.Single patient use60% lower resistance compared to Pall Microbial Filter Single Piece Combi: No need for current cartridge with Pall Microbial Filter and separate water trapDisposable Expiratory Filter/Water Trap
  • 25. Volume Controlled VentilationVolume Assist Control (AlC) ModeVolume SIMV ModePressure Support VentilationPressure Assist Control (AlC) ModePressure SIMVAirway Pressure Release Ventilation (APRV I Biphasic/Bilevel/BiPAP)Pressure Regulated Volume Control (PRVC) SIMV ModePressure Regulated Volume Control (PRVC) Assist Control (A/C) ModeTCPL SIMV Mode (time cycle pressure limit)TCPL Assist Control (AlC) ModeNeonatal Nasal nCPAP ModeContinuous Positive Airway Pressure with Pressure Support Ventilation (CPAP/PSV)Apnea Back up VentilationStandbyBreath Types and Modes
  • 26. CommunicationsAVEA offers a selection of protocols compatible with many patient monitoring and hospital information systems. A VGA output for training and a parallel port for printing
  • 27. Intuitive Operation & DisplayMode, screen and status indicators are easy to see at a distanceSelectable, full color graphics improve breath phase recognition(Red, Blue & Yellow)Five monitored values are visible to the user at all times: each is selectable from a menu of 54 options The intuitive “touch-turn-touch tm “ design reduces training time and enhances clinician confidence Valuable information is displayed to assist the practitioner with clinical decisions