ºÝºÝߣ

ºÝºÝߣShare a Scribd company logo
Project Profile
                                                         Slough Police Station - Slough

Consultant
¡ö    T&B



Client
¡ö    Perfect Pipework Ltd



Sector                      Front Entrance

¡ö Public



Products
¡ö MasterFlue System



Equipment
¡ö Potterton Derwent
    Hamworthy DR-LA40
                            Airtherm Masterflue
                            Airtherm Engineering has completed another installation using Nova
                            commercial product serving two existing Potteron Derwent atmosperic
Application                 boiler s & one Hamworthy water heater at Slough Police station.

                            Nova is a new breed of chimney system that offers a single solution for
¡ö Atmosperic                virtually all of today's combustion requirements. Nova is a true multi-
                            fuel / multi-application product, whether being used to serve a solid fuel
                            stove, vent the latest high efficiency condensing appliances or Biomass
                            wood chip / pellet stove, Nova is the product of choice. With a diameter
                            range covering thirteen sizes, Nova covers domestic and commercial
                            applications. Manufactured from a 316L inner liner, 25mm high density
                            insulated annulus and a grade 304 outer case, Nova is built to last.




        0844 809 2509 | airtherm.co.uk | info@airtherm.co.uk
Product Solution

                            ?    Boilers:            Potterton Derwent

                            ?    Water Heater:        Hamworthy DR-LA40
                            ?    Application:         Chimney / Flue system

                            ?    Operating mode:      Dry

                            ?    Pressure:            Negative / Positive pressure
                            ?    Working pressure: 200 Pa (product will operate 1000pa max)

                            ?    Inner wall:          316L1.4404/1.457 thickness ?500 1 mm

                            ?    Outer wall:          AISI 304/ 1.4301 thickness 0,6 mm

                            ?    Insulation:          25mm thick Rockwool insulation

                            ?    Sealant :             tri-lip 'o' type silicone ring
Nova Product
                            ?    Fuel type:            Gas



                            ? Suitable for fully condensing applications
                            ? Fully welded construction
                            ? High level insulation
                            ? High thermal resistance
                            ? High speed twist lock jointing system to aid installation
                            ? Without seals the product is suitable for multi fuel applications up to 450¡ãC

View of Chimney Top         Diameters: 100mm - 600mm
                            Construction: Twin Wall Insulated
                            Material: 316L stainless steel liner and 304 stainless steel outer case
 Contact Details:           Temperature: 450¡ãC Continuous without seals 200¡ãC with seals fitted
 Airtherm Engineering Ltd   Pressure capability: 200Pa (P1)
                            Mode of operation: Negative or positive pressure
 Ventilation House
 Pedmore                    Approvals:
 Stoubridge                 BS EN 1856-1 T460 N1 D V2 L50050 G(50) Nova SM
                            BS EN 1856-1 T600 N1 D V2 L50050 G(50) Nova SF
 West Midlands
                            BS EN 1856-1 T200 P1 W V2 L50050 O(50) Nova SM c/w seals
 DY9 0DS
                            Approvals:
                            BS EN 1856-1 T460 N1 D V2 L50050 G(50) Nova SM
 Tel: 0844 8092509          BS EN 1856-1 T600 N1 D V2 L50050 G(50) Nova SF
 Fax: 01562 887312          BS EN 1856-1 T200 P1 W V2 L50050 O(50) Nova SM c/w seals




               0844 809 2509 | airtherm.co.uk | info@airtherm.co.uk

More Related Content

Case study for slough police station

  • 1. Project Profile Slough Police Station - Slough Consultant ¡ö T&B Client ¡ö Perfect Pipework Ltd Sector Front Entrance ¡ö Public Products ¡ö MasterFlue System Equipment ¡ö Potterton Derwent Hamworthy DR-LA40 Airtherm Masterflue Airtherm Engineering has completed another installation using Nova commercial product serving two existing Potteron Derwent atmosperic Application boiler s & one Hamworthy water heater at Slough Police station. Nova is a new breed of chimney system that offers a single solution for ¡ö Atmosperic virtually all of today's combustion requirements. Nova is a true multi- fuel / multi-application product, whether being used to serve a solid fuel stove, vent the latest high efficiency condensing appliances or Biomass wood chip / pellet stove, Nova is the product of choice. With a diameter range covering thirteen sizes, Nova covers domestic and commercial applications. Manufactured from a 316L inner liner, 25mm high density insulated annulus and a grade 304 outer case, Nova is built to last. 0844 809 2509 | airtherm.co.uk | info@airtherm.co.uk
  • 2. Product Solution ? Boilers: Potterton Derwent ? Water Heater: Hamworthy DR-LA40 ? Application: Chimney / Flue system ? Operating mode: Dry ? Pressure: Negative / Positive pressure ? Working pressure: 200 Pa (product will operate 1000pa max) ? Inner wall: 316L1.4404/1.457 thickness ?500 1 mm ? Outer wall: AISI 304/ 1.4301 thickness 0,6 mm ? Insulation: 25mm thick Rockwool insulation ? Sealant : tri-lip 'o' type silicone ring Nova Product ? Fuel type: Gas ? Suitable for fully condensing applications ? Fully welded construction ? High level insulation ? High thermal resistance ? High speed twist lock jointing system to aid installation ? Without seals the product is suitable for multi fuel applications up to 450¡ãC View of Chimney Top Diameters: 100mm - 600mm Construction: Twin Wall Insulated Material: 316L stainless steel liner and 304 stainless steel outer case Contact Details: Temperature: 450¡ãC Continuous without seals 200¡ãC with seals fitted Airtherm Engineering Ltd Pressure capability: 200Pa (P1) Mode of operation: Negative or positive pressure Ventilation House Pedmore Approvals: Stoubridge BS EN 1856-1 T460 N1 D V2 L50050 G(50) Nova SM BS EN 1856-1 T600 N1 D V2 L50050 G(50) Nova SF West Midlands BS EN 1856-1 T200 P1 W V2 L50050 O(50) Nova SM c/w seals DY9 0DS Approvals: BS EN 1856-1 T460 N1 D V2 L50050 G(50) Nova SM Tel: 0844 8092509 BS EN 1856-1 T600 N1 D V2 L50050 G(50) Nova SF Fax: 01562 887312 BS EN 1856-1 T200 P1 W V2 L50050 O(50) Nova SM c/w seals 0844 809 2509 | airtherm.co.uk | info@airtherm.co.uk