際際滷

際際滷Share a Scribd company logo
FEC Choices for 802.3ca
Eugene (Yuxin) Dai
Cox Communications
IEEE 802.3ca 100G EPON TF, IEEE Plenary Meeting
November, 2017
Orlando, FL, USA
Optical power budget gap in 802.3ca
 There is a power budget gap for signal channel 25G EPON
 The gap could be filled with combination of FEC gain,
higher TX power and higher RX sensitivity
 Power budget gap for multi-channel 50G and/or 100G is
bigger and more difficult to fill
 FEC alone cannot composite WDM mux/dmux loss
 SOA is needed; channelized SOA may be needed because
of the 20nm width. The cost is a serious concern.
 The signal channel 50G EPON with PAM4 modulation needs a
SOA to compensate the 4-5 dB PAM4 power penalty.
 The gap may be easier to fill with SOA
This contribution discusses the FEC choice for 25G EPON, 50G
EPON, 100G system point of view
2
FEC proposals for 25G
 BCH, RS and LDPC have been proposed
 Recent debates were focused on the choices
between RS and LDPC
 One opinion was to use higher FEC code gains
possible to loosen the spec on TX power
 Other opinion was to choose small code size FEC to
lower the latency
 No convergence on the subject yet
 The 50G PAM4 will add another consideration to FEC
choices
3
Code gains, latency, complicity and 50G PAM4 may
need considering together along with the applications
FEC code gains, latency and complexity
* laubach_3ca_1a_0917.pdf
FEC code gains and latency*
 The code gains for AWGN of LDPC (184931,15677) is
0.66dB (36%) higher than RS (2048,1536)
 The latency of LDPC (184931,15677) is 4.15us (269%)
longer than RS (2048,1536)
 Implementation of LDPC is more complicated
Applications of LDPC and RS
 The Low Density Parity Check code was first introduced
in 1960s. Its practical implementations didnt happen
only until recent years
 The LDPC is mostly used in copper and wireless system
due to its good performance in these channels
 DVB, G.hn, EPOC, DOCSIS 3.1, etc.
 LDPC was used in delay insensitive network/system such
as broadcast, home network, residential access network,
etc.
 RS has been used in fiber optical communication system,
long-haul, metro and access
LDPC or RS for 25G EPON?
 The power budget gap of 25G can only be filled with FEC
code gains and higher TX power (fix APD RX sensitivity. No
optical amplification)
 The emerging killer applications of high-speed PON, such as
25G EPON, may be in the network transport section, for
example 5G mobile fronthaul and backhaul.
 Low latency is essential for these applications
 5G mobile fronthaul latency budget allocated for PON section ~ 250us
 Although FEC delay is a small portion, but it can't be reduced once it is there
 Transmitter technology has been improving, leave the
0.66dB power budget difference to TX is feasible
Choose small code size FEC for lower latency for
network transport applications
LDPC or RS for 50G PAM4?
 In order to compensate the 4 to 5 dB power penalties of
PAM4, optical amplification, such as SOA, is needed for
50G serial PON
 The power budget gap can be easily filled with proper
choose the optical amplification gains
 LDPC has no advantage for 50G PAM4 in comparison
with RS
 LDPC has higher latency, higher complexity
 The extra code gain of LDPC is covered by SOA
 RS is a better choice for 50G PAM4
Conclusions
 Low latency is essential for emerging network
transport applications for 25G and 50G EPON
 For 25G EPON with NRZ, choosing a small FEC code
size to lower latency and leverage TX power is an
optimized solution
 For 4x25G since SOA are needed, RS is a better
choice
 For 50G EPON with PAM4, RS is a better choice
8
9
Thanks
Eugene.dai@cox.com

More Related Content

dai_3ca_2a_1117-LDPC ab tud tndite gain.pdf

  • 1. FEC Choices for 802.3ca Eugene (Yuxin) Dai Cox Communications IEEE 802.3ca 100G EPON TF, IEEE Plenary Meeting November, 2017 Orlando, FL, USA
  • 2. Optical power budget gap in 802.3ca There is a power budget gap for signal channel 25G EPON The gap could be filled with combination of FEC gain, higher TX power and higher RX sensitivity Power budget gap for multi-channel 50G and/or 100G is bigger and more difficult to fill FEC alone cannot composite WDM mux/dmux loss SOA is needed; channelized SOA may be needed because of the 20nm width. The cost is a serious concern. The signal channel 50G EPON with PAM4 modulation needs a SOA to compensate the 4-5 dB PAM4 power penalty. The gap may be easier to fill with SOA This contribution discusses the FEC choice for 25G EPON, 50G EPON, 100G system point of view 2
  • 3. FEC proposals for 25G BCH, RS and LDPC have been proposed Recent debates were focused on the choices between RS and LDPC One opinion was to use higher FEC code gains possible to loosen the spec on TX power Other opinion was to choose small code size FEC to lower the latency No convergence on the subject yet The 50G PAM4 will add another consideration to FEC choices 3 Code gains, latency, complicity and 50G PAM4 may need considering together along with the applications
  • 4. FEC code gains, latency and complexity * laubach_3ca_1a_0917.pdf FEC code gains and latency* The code gains for AWGN of LDPC (184931,15677) is 0.66dB (36%) higher than RS (2048,1536) The latency of LDPC (184931,15677) is 4.15us (269%) longer than RS (2048,1536) Implementation of LDPC is more complicated
  • 5. Applications of LDPC and RS The Low Density Parity Check code was first introduced in 1960s. Its practical implementations didnt happen only until recent years The LDPC is mostly used in copper and wireless system due to its good performance in these channels DVB, G.hn, EPOC, DOCSIS 3.1, etc. LDPC was used in delay insensitive network/system such as broadcast, home network, residential access network, etc. RS has been used in fiber optical communication system, long-haul, metro and access
  • 6. LDPC or RS for 25G EPON? The power budget gap of 25G can only be filled with FEC code gains and higher TX power (fix APD RX sensitivity. No optical amplification) The emerging killer applications of high-speed PON, such as 25G EPON, may be in the network transport section, for example 5G mobile fronthaul and backhaul. Low latency is essential for these applications 5G mobile fronthaul latency budget allocated for PON section ~ 250us Although FEC delay is a small portion, but it can't be reduced once it is there Transmitter technology has been improving, leave the 0.66dB power budget difference to TX is feasible Choose small code size FEC for lower latency for network transport applications
  • 7. LDPC or RS for 50G PAM4? In order to compensate the 4 to 5 dB power penalties of PAM4, optical amplification, such as SOA, is needed for 50G serial PON The power budget gap can be easily filled with proper choose the optical amplification gains LDPC has no advantage for 50G PAM4 in comparison with RS LDPC has higher latency, higher complexity The extra code gain of LDPC is covered by SOA RS is a better choice for 50G PAM4
  • 8. Conclusions Low latency is essential for emerging network transport applications for 25G and 50G EPON For 25G EPON with NRZ, choosing a small FEC code size to lower latency and leverage TX power is an optimized solution For 4x25G since SOA are needed, RS is a better choice For 50G EPON with PAM4, RS is a better choice 8