MaxLite cites inaccuracies in James Industry response to UL public notice
In the interest of public safety, MaxLite is addressing several important points absent from a James
Industry press release about the UL warning on that companys Direct Replacement Dual-Mode LED
Tube (Model Number ZY-T8-18W1200 BIXX).
West Caldwell, NJ (July 17, 2017)  On July 5, 2017, UL issued a warning concerning
potential hazards presented by James Industrys Direct Replacement Dual-Mode LED Tube,
Model Number ZY-T8-18W1200 BIXX. ULs position is that this product does not comply
with UL Standards for Safety, bears an unauthorized UL Mark for the United States and
Canada, and poses a potential fire hazard.
On July 11, 2017, James Industry, the company whose product was the subject of the UL
report, issued a statement that the UL warning was limited to the companys initial 1,000
pieces, which were production samples produced in 2014, and that all 1,000 pieces have
since been returned to the factory in China.
There are several important points that are absent from the James Industry statement that
should be clarified in the interest of public safety:
First, the James Industry product in question is a Dual-Mode LED retrofit tube. As such, it
combines a Type A (ballast connected) mode and a Type B (ballast bypass) mode in a
single tube, and also allows for single-sided or double-sided installation. There is currently
no UL standard that specifically covers these new dual-mode tubes; thus, for example,
since it can act as a Type B tube, a dual-mode tube presents the same potential safety
issues as a Type B tube but can easily be presented to UL and/or sold as a Type A tube.
Yet the UL instruction and warning requirements that apply to Type B tubes (as mandated
under UL1598C) are not required in the case of dual-mode tubes.
Second, the use of dual-mode LED replacement tubes is potentially dangerous, resulting in
the routine mislabeling of lamps; the lack of necessary warning markings; increased risk of
fire; increased risk of shock; voiding of the fixtures UL Listing; and ineligibility for utility
rebates.
The typical scenario is as follows: when a dual-mode lamp is installed, it will either be
connected to an existing ballast or directly to the branch circuit. Either way, the dual-mode
lamp creates a dangerous situation: (i) If the dual-mode product is connected directly to the
branch circuit (i.e., a ballast-bypass installation), the person wiring the fixture will not have
access to the appropriate warning labels to affix to the fixture as required under UL1598C,
resulting in a non-compliant and potentially dangerous installation. Crucial safety
information such as the appropriate replacement lamp type will be missing or incorrect and,
in addition, the UL listing on the fixture is voided (something that the dual-mode lamp sellers
do not tell their customers), and (ii) If the dual-mode product is connected to a ballast, then
when the ballast eventually fails (which is not unlikely) and the dual-mode fixture is being
rewired, the person removing the ballast and re-wiring the fixture will not have access to the
appropriate warning labels to affix to the fixture as required under UL1598C, resulting, as
described in the preceding paragraph, in a non-compliant installation.
Of further concern in the case of nearly all dual-mode products is that a potential shock
hazard is presented if one end of the dual mode tube is installed into a live lamp holder
while the pins on the other end are exposed to contact by the installer. The danger is
magnified when taking into account the reaction hazard present if the installer is standing on
a ladder or scaffold at the time of installation. (It should be noted that certain manufacturers
claim that their dual-mode tube design does not present this shock hazard.)
Disturbingly, there have been reports of fires involving the James Industry Direct
Replacement Dual-Mode LED Tubes, including the very tube that was identified in the UL
report (Model Number ZY-T8-18W1200 BIXX).
On October 8, 2016, a fire erupted at the four-story Four Seasons Homeowners Association
building, located in Beverly Hills, California. The fire and resulting smoke condition caused
damage throughout the building and its cause is currently under investigation. The fire
began in a James Industries Direct Replacement Dual-Mode LED Tube (Model Number ZY-
T8-18W1200 BIXX).
James Industry Dual-Mode T-8 Replacement Tube Model No. ZY-T8-18W1200 BIXX in
which the HOA fire began (cause under investigation).
.
Another view of the James Industry Tube Model NO. ZY-T8-18W1200 BIXX.
Another fire occurred on December 7, 2016 in Chelsea, Massachusetts at a large cold
storage facility owned by State Garden, Inc. This fire again involved a James Industry dual-
mode LED retrofit T8 tube.
James Industrys assertion that all of the products subject to ULs warning have been pulled
from the market and returned to China, and the suggestion that the currently installed
inventory is safe, is suspect. In fact, NEMA and UL have begun to recognize the important
safety issues facing dual-mode LED retrofit tubes. MaxLite has been informed by NEMA
that a task force was formed to address this issue and publish a whitepaper. UL has also
recently reviewed and accepted a proposal concerning new marking requirements to be
added to UL 1993 for the labeling of dual-mode products. These new requirements would, if
added to the Standard following the comment and ratification process, mandate that dual-
mode tubes comply with the Type B labeling requirements and be labeled as both Type A
and Type B.
One final point  the industry is aware of the significant number of LED lighting rebate
programs run by utilities throughout the United States. In the case of LED tubes, these
rebate programs often limit rebate eligibility to either Type A or Type B tubes. However, a
dual-mode tube can be passed off as either a Type A or a Type B tube, allowing for the
circumvention of the restrictions imposed by the utilities. This has happened numerous
times in the field over the past year or so. This is likely to become a more significant issue
as the utilities become increasingly aware of this situation.
Links
UL Public Notice: http://www.ul.com/newsroom/publicnotices/ul-warns-of-potentially-
hazardous-led-tube-lamps/
James Industry Statement: http://jamesindustry.com/content/?410.html
###

More Related Content

Dual mode LED tubes and UL

  • 1. Media contact: Amy Silver, 973.244.7300 x111, asilver@maxlite.com MaxLite cites inaccuracies in James Industry response to UL public notice In the interest of public safety, MaxLite is addressing several important points absent from a James Industry press release about the UL warning on that companys Direct Replacement Dual-Mode LED Tube (Model Number ZY-T8-18W1200 BIXX). West Caldwell, NJ (July 17, 2017) On July 5, 2017, UL issued a warning concerning potential hazards presented by James Industrys Direct Replacement Dual-Mode LED Tube, Model Number ZY-T8-18W1200 BIXX. ULs position is that this product does not comply with UL Standards for Safety, bears an unauthorized UL Mark for the United States and Canada, and poses a potential fire hazard. On July 11, 2017, James Industry, the company whose product was the subject of the UL report, issued a statement that the UL warning was limited to the companys initial 1,000 pieces, which were production samples produced in 2014, and that all 1,000 pieces have since been returned to the factory in China. There are several important points that are absent from the James Industry statement that should be clarified in the interest of public safety: First, the James Industry product in question is a Dual-Mode LED retrofit tube. As such, it combines a Type A (ballast connected) mode and a Type B (ballast bypass) mode in a single tube, and also allows for single-sided or double-sided installation. There is currently no UL standard that specifically covers these new dual-mode tubes; thus, for example, since it can act as a Type B tube, a dual-mode tube presents the same potential safety issues as a Type B tube but can easily be presented to UL and/or sold as a Type A tube. Yet the UL instruction and warning requirements that apply to Type B tubes (as mandated under UL1598C) are not required in the case of dual-mode tubes. Second, the use of dual-mode LED replacement tubes is potentially dangerous, resulting in the routine mislabeling of lamps; the lack of necessary warning markings; increased risk of fire; increased risk of shock; voiding of the fixtures UL Listing; and ineligibility for utility rebates. The typical scenario is as follows: when a dual-mode lamp is installed, it will either be connected to an existing ballast or directly to the branch circuit. Either way, the dual-mode lamp creates a dangerous situation: (i) If the dual-mode product is connected directly to the branch circuit (i.e., a ballast-bypass installation), the person wiring the fixture will not have access to the appropriate warning labels to affix to the fixture as required under UL1598C, resulting in a non-compliant and potentially dangerous installation. Crucial safety information such as the appropriate replacement lamp type will be missing or incorrect and, in addition, the UL listing on the fixture is voided (something that the dual-mode lamp sellers do not tell their customers), and (ii) If the dual-mode product is connected to a ballast, then when the ballast eventually fails (which is not unlikely) and the dual-mode fixture is being rewired, the person removing the ballast and re-wiring the fixture will not have access to the
  • 2. appropriate warning labels to affix to the fixture as required under UL1598C, resulting, as described in the preceding paragraph, in a non-compliant installation. Of further concern in the case of nearly all dual-mode products is that a potential shock hazard is presented if one end of the dual mode tube is installed into a live lamp holder while the pins on the other end are exposed to contact by the installer. The danger is magnified when taking into account the reaction hazard present if the installer is standing on a ladder or scaffold at the time of installation. (It should be noted that certain manufacturers claim that their dual-mode tube design does not present this shock hazard.) Disturbingly, there have been reports of fires involving the James Industry Direct Replacement Dual-Mode LED Tubes, including the very tube that was identified in the UL report (Model Number ZY-T8-18W1200 BIXX). On October 8, 2016, a fire erupted at the four-story Four Seasons Homeowners Association building, located in Beverly Hills, California. The fire and resulting smoke condition caused damage throughout the building and its cause is currently under investigation. The fire began in a James Industries Direct Replacement Dual-Mode LED Tube (Model Number ZY- T8-18W1200 BIXX). James Industry Dual-Mode T-8 Replacement Tube Model No. ZY-T8-18W1200 BIXX in which the HOA fire began (cause under investigation). . Another view of the James Industry Tube Model NO. ZY-T8-18W1200 BIXX.
  • 3. Another fire occurred on December 7, 2016 in Chelsea, Massachusetts at a large cold storage facility owned by State Garden, Inc. This fire again involved a James Industry dual- mode LED retrofit T8 tube. James Industrys assertion that all of the products subject to ULs warning have been pulled from the market and returned to China, and the suggestion that the currently installed inventory is safe, is suspect. In fact, NEMA and UL have begun to recognize the important safety issues facing dual-mode LED retrofit tubes. MaxLite has been informed by NEMA that a task force was formed to address this issue and publish a whitepaper. UL has also recently reviewed and accepted a proposal concerning new marking requirements to be added to UL 1993 for the labeling of dual-mode products. These new requirements would, if added to the Standard following the comment and ratification process, mandate that dual- mode tubes comply with the Type B labeling requirements and be labeled as both Type A and Type B. One final point the industry is aware of the significant number of LED lighting rebate programs run by utilities throughout the United States. In the case of LED tubes, these rebate programs often limit rebate eligibility to either Type A or Type B tubes. However, a dual-mode tube can be passed off as either a Type A or a Type B tube, allowing for the circumvention of the restrictions imposed by the utilities. This has happened numerous times in the field over the past year or so. This is likely to become a more significant issue as the utilities become increasingly aware of this situation. Links UL Public Notice: http://www.ul.com/newsroom/publicnotices/ul-warns-of-potentially- hazardous-led-tube-lamps/ James Industry Statement: http://jamesindustry.com/content/?410.html ###