ºÝºÝߣ

ºÝºÝߣShare a Scribd company logo
DAYSENSOR
DYHW-120 Micro-scale pressure sensor
Features:
¡¤High stability
¡¤Can be installed in a small space
¡¤Can be non-standard customized
¡¤Anti-interference signals are stable
¡¤Quality stainless steel
¡¤It is widely used in 3C digital
manufacturing detection process force
measurement, power equipment, mechanical
arm and other automation fields.
¼¼ÊõÖ¸±ê
Rated quantitative schedule Kg 0-1000
Output sensitivity mV/V 1.0-2.0
Zero point output %F.S. ¡À2
Non-linear %F.S. 0.3
lag %F.S. 0.3
Repeatability %F.S. 0.1
Creep (30 min) %F.S. 0.05
Temperature sensitivity drift %F.S./10¡æ 0.3
Zero temperature drift %F.S./10¡æ 0.3
Response frequency Hz 1k
Material stainless steel
impedance ¦¸ 1000
Insulation resistance M¦¸/100V DC ¡Ý5000
Use voltage V 5-10
Operating temperature range ¡æ -20-80
Safety overload %R.C. 150
Extreme overload %R.C. 200
Cable line specifications m ¦µ3*2m
Cable limit pull force N 98
TEDS selectable
1) High temperature sensors are available, with a maximum operating temperature of 150¡æ.
2) High impedance sensors can be provided with an output impedance of 1000 ¦¸.
https://www.loadcells.store
DAYSENSOR
Product Size Fig
Unit: mm
Range(kg) 500-1000 1500-2000
D 3.8 3
Range(kg) 5 10-50 100-200
B 2 2.5 3
force diagram
Center convex point force

More Related Content

DYHW-120.pdf

  • 1. DAYSENSOR DYHW-120 Micro-scale pressure sensor Features: ¡¤High stability ¡¤Can be installed in a small space ¡¤Can be non-standard customized ¡¤Anti-interference signals are stable ¡¤Quality stainless steel ¡¤It is widely used in 3C digital manufacturing detection process force measurement, power equipment, mechanical arm and other automation fields. ¼¼ÊõÖ¸±ê Rated quantitative schedule Kg 0-1000 Output sensitivity mV/V 1.0-2.0 Zero point output %F.S. ¡À2 Non-linear %F.S. 0.3 lag %F.S. 0.3 Repeatability %F.S. 0.1 Creep (30 min) %F.S. 0.05 Temperature sensitivity drift %F.S./10¡æ 0.3 Zero temperature drift %F.S./10¡æ 0.3 Response frequency Hz 1k Material stainless steel impedance ¦¸ 1000 Insulation resistance M¦¸/100V DC ¡Ý5000 Use voltage V 5-10 Operating temperature range ¡æ -20-80 Safety overload %R.C. 150 Extreme overload %R.C. 200 Cable line specifications m ¦µ3*2m Cable limit pull force N 98 TEDS selectable 1) High temperature sensors are available, with a maximum operating temperature of 150¡æ. 2) High impedance sensors can be provided with an output impedance of 1000 ¦¸. https://www.loadcells.store
  • 2. DAYSENSOR Product Size Fig Unit: mm Range(kg) 500-1000 1500-2000 D 3.8 3 Range(kg) 5 10-50 100-200 B 2 2.5 3 force diagram Center convex point force