ºÝºÝߣ

ºÝºÝߣShare a Scribd company logo
DAYSENSOR
DYLY-107 Type S pull pressure sensor
Features:
·Pull pressure two-way force
·The structure is compact
·The comprehensive accuracy is high
·Long-term stability is good
·Quality alloy steel with nickel plating
·Universal material test machine, hopper
scale, hook scale, packaging scale, belt
scale, plug force tester and other pull
pressure test instruments and automation
equipment and test fields.
qualification
Rated quantitative schedule Kg 200
Output sensitivity mV/V 1.0-2.0
Zero point output %F.S. ±2
Non-linear %F.S. 0.05
lag %F.S. 0.03
Repeatability %F.S. 0.03
Creep (30 min) %F.S. 0.03
Temperature sensitivity drift %F.S./10℃ 0.03
Zero temperature drift %F.S./10℃ 0.05
Response frequency Hz 1k
Material stainless steel
impedance Ω 350
Insulation resistance MΩ/100V DC ≥5000
Use voltage V 5-10
Operating temperature range ℃ -20-80
Safety overload %R.C. 150
Extreme overload %R.C. 200
Cable line specifications m Φ3*2m
Cable limit pull force N 98
TEDS selectable
1) High temperature sensors are available, with a maximum operating temperature of 150℃.
2) High impedance sensors can be provided with an output impedance of 1000 Ω.
https://www.loadcells.store
DAYSENSOR
Product Size Fig
Unit: mm
Range(kg) 5 10 20 30 50 100 200
force diagram
Up and lower threaded hole connection

More Related Content

DYLY-107.pdf

  • 1. DAYSENSOR DYLY-107 Type S pull pressure sensor Features: ·Pull pressure two-way force ·The structure is compact ·The comprehensive accuracy is high ·Long-term stability is good ·Quality alloy steel with nickel plating ·Universal material test machine, hopper scale, hook scale, packaging scale, belt scale, plug force tester and other pull pressure test instruments and automation equipment and test fields. qualification Rated quantitative schedule Kg 200 Output sensitivity mV/V 1.0-2.0 Zero point output %F.S. ±2 Non-linear %F.S. 0.05 lag %F.S. 0.03 Repeatability %F.S. 0.03 Creep (30 min) %F.S. 0.03 Temperature sensitivity drift %F.S./10℃ 0.03 Zero temperature drift %F.S./10℃ 0.05 Response frequency Hz 1k Material stainless steel impedance Ω 350 Insulation resistance MΩ/100V DC ≥5000 Use voltage V 5-10 Operating temperature range ℃ -20-80 Safety overload %R.C. 150 Extreme overload %R.C. 200 Cable line specifications m Φ3*2m Cable limit pull force N 98 TEDS selectable 1) High temperature sensors are available, with a maximum operating temperature of 150℃. 2) High impedance sensors can be provided with an output impedance of 1000 Ω. https://www.loadcells.store
  • 2. DAYSENSOR Product Size Fig Unit: mm Range(kg) 5 10 20 30 50 100 200 force diagram Up and lower threaded hole connection