際際滷

際際滷Share a Scribd company logo
Electrician club with cables
Electrician club with cables
 High impact & Flame Retardant Polycarbonate material
 Flame Retardant Nylon Material
 High Grade Brass for Terminals, Screws & Components
 Phosphor Bronze Socket Contacts
 High Quality Silver Alloy for Contact Surfaces
Comply with SLS, IEC, EN 60669-1:1999, BS 546:1950, BS 546, SS145, SS 241:1996 ,
SS 472:1999, SS 241:1996, IEC 60669-1:1999, BS 1363-2:1995, MS 589-2:2011, ISO
9001:2008 Certified Company
(Range - X05/X06/X07/X08)
HOW IT WORKS
Electrician club with cables
 High impact & Flame Retardant Polycarbonate material
 Flame Retardant Nylon Material
 High Grade Brass for Terminals , Screws & Components
 Phosphor Bronze Socket Contacts
 High Quality Silver Alloy for Contact Surfaces
Comply with SLS, IEC, EN 60669-1:1999, BS 546:1950, BS 546, SS145,
SS 241:1996 , SS 472:1999, SS 241:1996, IEC 60669-1:1999, BS 1363-2:1995,
MS 589-2:2011,
Electrician club with cables
PIONEER IN MANUFACTURING
SRI LANKAS FIRST OXYGEN FREE CABLE
Why ORANGE Cables
 Orange use 99.99% Pure Copper
 Oxygen Free Copper
 Value addition to the nation through circulation of copper in
house
Features & Benefits of Oxygen free copper
Features Benefits
High Conductivity Good Electricity
Corrosion Resistance Long Lasting
ClimateHardiness Long Lasting
Elongation won'tbreake
Good HeatConduction SaveElectricity
INDOOR CABLES 0.20  50mm
Manufactured to BS - 6500 to a
voltage range of 300/500V and
450/750V for wiring in - house and
commercial buildings(SLS 733)
UNARMOURED POWER CABLES
Manufactured to BS - 6346 and
BS - 5467 to a voltage rating of
600/1000V,for distribution of
electricity within cities, factories &
buildings. 2C,3C,4C,5C 1.5mm 
16mm
Switchgear Cables
Manufactured to BS - 6231 to a
voltage rating of 600/1000V for
wiring of swithgear and
controlgear inside control panel
1mm  50mm
Data CABLES
Telephone Cables 1 to
5 pair, Cat 5e & Cat 6e
Cables
AUTO CABLES
Flexible copper conductors
PVC insulated manufactured
for a voltage of 100V. These
cables are used for electricle
wiring of motor vehicle.
COAXIAL AND RG CABLES
5C2V
3C2V
RG 6
Ensure Circuit Protections with
ORANGE
Alfa/Sigma
MCB Functions
 Overload protection
 Short Circuit protection
o Isolation
Symbol
Tripping lever
Operating
mechanism
Operator
Space for
identification
marker
Electro-magnetic protection Upper
terminal
Thermal
protection bimetal
Arc
chamber
Fixed
contact
Moving
contact
DIN rail holder
Lower terminal
Basic Construction & Normal
operating condition
Bi-Metal strip
(Thermal)
Electro magnet
(Magnetic)
Contacts
Tripping mechanism
Thermal tripping at Overload
Condition
Bi-Metal strip
(Thermal)
Electro magnet
(Magnetic)
Contacts
Tripping mechanism
Magnetic tripping at Short cct
Condition
Bi-Metal strip
(Thermal)
Electro magnet
(Magnetic)
Contacts
Tripping mechanism
Customer Request
 Rating (Current Rating)
6A , 10A , 16A , 20A , 25A , 32A , 40A , 63A
Also 80A , 100A , 125A
Standard Ratings (Corresponding voltage AC/DC & F)
 No of Poles
1 P , 2P , 3P , 4P
 Curve
B , C , D , 
 Breaking Capacity
4.5KA ,6 KA, 10KA ,15KA- (Up to 50 KA), (Corresponding
voltage AC/DC & F)
Tripping Curve
(Thermal/Magnetic)
Time
Current multiplesIm
Ir
Over load Short circuit
Tripping
curve -B
Tripping
curve -C
Breaking Capacity
 It is current that a circuit breaker is capable of breaking at a
given recovery voltage under specified conditions
 The breaking capacity of the circuit breaker must be at least
or equal to the prospective short-circuit current at its point of
installation.
 4.5KA ,6 KA, 10KA ,15KA- (Up to 50 KA),
RCCB
Residual Current Circuit Breaker
Critical current thresholds
Protection of life and property
Standard IEC 60479-1
Cardiac arrest
Irreversible cardiac
fibrillation
Breathing arrest
Muscular contraction
Tingling
1 A
75 mA
30 mA
10mA
0.5 mA
mA
The principle of Residual Current Devices
The principle of Residual Current
Devices
Industrial Switch Gears
TV/Fridge/Telephone Socket
6500A
IEC61643-1 Class III
Light Up Life with ORANGE
CFL/ LED Technology
 Tri-phosphor coating for high luminous output .
 8000H life span
 All lamps are energy efficiency labeled and
3 star and above.
 High quality metal product to withstand adverse conditions
 High Quality Powder coated finish
 High impact Flame Retardant Polycarbonate material
 Flame Retardant Nylon Material
 High Grade Brass for Terminals ,Screws & Components
 Phosphor Bronze Socket Contacts
 High Quality Silver Alloy for Contact Surfaces
Comply with SLS, IEC, EN 60669-1:1999, BS 546:1950, BS 546, SS145,
SS 241:1996 , SS 472:1999, SS 241:1996, IEC 60669-1:1999, BS 1363-2:1995,
MS 589-2:2011, ISO 9001:2008 Certified Company
Industrial Panel Boards
Electrician club with cables

More Related Content

Electrician club with cables

  • 3. High impact & Flame Retardant Polycarbonate material Flame Retardant Nylon Material High Grade Brass for Terminals, Screws & Components Phosphor Bronze Socket Contacts High Quality Silver Alloy for Contact Surfaces Comply with SLS, IEC, EN 60669-1:1999, BS 546:1950, BS 546, SS145, SS 241:1996 , SS 472:1999, SS 241:1996, IEC 60669-1:1999, BS 1363-2:1995, MS 589-2:2011, ISO 9001:2008 Certified Company (Range - X05/X06/X07/X08)
  • 6. High impact & Flame Retardant Polycarbonate material Flame Retardant Nylon Material High Grade Brass for Terminals , Screws & Components Phosphor Bronze Socket Contacts High Quality Silver Alloy for Contact Surfaces Comply with SLS, IEC, EN 60669-1:1999, BS 546:1950, BS 546, SS145, SS 241:1996 , SS 472:1999, SS 241:1996, IEC 60669-1:1999, BS 1363-2:1995, MS 589-2:2011,
  • 8. PIONEER IN MANUFACTURING SRI LANKAS FIRST OXYGEN FREE CABLE
  • 9. Why ORANGE Cables Orange use 99.99% Pure Copper Oxygen Free Copper Value addition to the nation through circulation of copper in house
  • 10. Features & Benefits of Oxygen free copper Features Benefits High Conductivity Good Electricity Corrosion Resistance Long Lasting ClimateHardiness Long Lasting Elongation won'tbreake Good HeatConduction SaveElectricity
  • 11. INDOOR CABLES 0.20 50mm Manufactured to BS - 6500 to a voltage range of 300/500V and 450/750V for wiring in - house and commercial buildings(SLS 733)
  • 12. UNARMOURED POWER CABLES Manufactured to BS - 6346 and BS - 5467 to a voltage rating of 600/1000V,for distribution of electricity within cities, factories & buildings. 2C,3C,4C,5C 1.5mm 16mm
  • 13. Switchgear Cables Manufactured to BS - 6231 to a voltage rating of 600/1000V for wiring of swithgear and controlgear inside control panel 1mm 50mm
  • 14. Data CABLES Telephone Cables 1 to 5 pair, Cat 5e & Cat 6e Cables
  • 15. AUTO CABLES Flexible copper conductors PVC insulated manufactured for a voltage of 100V. These cables are used for electricle wiring of motor vehicle.
  • 16. COAXIAL AND RG CABLES 5C2V 3C2V RG 6
  • 17. Ensure Circuit Protections with ORANGE Alfa/Sigma
  • 18. MCB Functions Overload protection Short Circuit protection o Isolation Symbol
  • 19. Tripping lever Operating mechanism Operator Space for identification marker Electro-magnetic protection Upper terminal Thermal protection bimetal Arc chamber Fixed contact Moving contact DIN rail holder Lower terminal
  • 20. Basic Construction & Normal operating condition Bi-Metal strip (Thermal) Electro magnet (Magnetic) Contacts Tripping mechanism
  • 21. Thermal tripping at Overload Condition Bi-Metal strip (Thermal) Electro magnet (Magnetic) Contacts Tripping mechanism
  • 22. Magnetic tripping at Short cct Condition Bi-Metal strip (Thermal) Electro magnet (Magnetic) Contacts Tripping mechanism
  • 23. Customer Request Rating (Current Rating) 6A , 10A , 16A , 20A , 25A , 32A , 40A , 63A Also 80A , 100A , 125A Standard Ratings (Corresponding voltage AC/DC & F) No of Poles 1 P , 2P , 3P , 4P Curve B , C , D , Breaking Capacity 4.5KA ,6 KA, 10KA ,15KA- (Up to 50 KA), (Corresponding voltage AC/DC & F)
  • 27. Breaking Capacity It is current that a circuit breaker is capable of breaking at a given recovery voltage under specified conditions The breaking capacity of the circuit breaker must be at least or equal to the prospective short-circuit current at its point of installation. 4.5KA ,6 KA, 10KA ,15KA- (Up to 50 KA),
  • 29. Critical current thresholds Protection of life and property Standard IEC 60479-1 Cardiac arrest Irreversible cardiac fibrillation Breathing arrest Muscular contraction Tingling 1 A 75 mA 30 mA 10mA 0.5 mA mA
  • 30. The principle of Residual Current Devices
  • 31. The principle of Residual Current Devices
  • 34. Light Up Life with ORANGE CFL/ LED Technology Tri-phosphor coating for high luminous output . 8000H life span All lamps are energy efficiency labeled and 3 star and above.
  • 35. High quality metal product to withstand adverse conditions High Quality Powder coated finish High impact Flame Retardant Polycarbonate material Flame Retardant Nylon Material High Grade Brass for Terminals ,Screws & Components Phosphor Bronze Socket Contacts High Quality Silver Alloy for Contact Surfaces Comply with SLS, IEC, EN 60669-1:1999, BS 546:1950, BS 546, SS145, SS 241:1996 , SS 472:1999, SS 241:1996, IEC 60669-1:1999, BS 1363-2:1995, MS 589-2:2011, ISO 9001:2008 Certified Company