Elica TechLab is a laboratory for testing SMT and CTDP that is designed according to international standards including UNI EN/IEC UL ISO 17025 and UNI EN/IEC ISO 17025. The document outlines the various testing services provided by Elica TechLab including safety tests, tests on non-metallic materials, efficiency tests, reliability tests, packaging tests, noise and performance tests, and EMC tests. The goal is to help customers minimize time to market by ensuring products meet international standards and performance requirements.
1 of 15
Download to read offline
More Related Content
Elica Tech Lab
1. Elica TechLab
SMT&CTDP Laboratory
Design according to
UNI EN/IEC UL ISO 17025
UNI EN/IEC ISO 17025
Elica TechLab opens its doors
2. Elica TechLab
SMT&CTDP Laboratory
Design according to
UNI EN/IEC UL ISO 17025
UNI EN/IEC ISO 17025
Design
We can drive your product development since the beginning, choosing
THE RIGHT MATERIALS
THE RIGHT COMPONENTS
THE RIGHT CONSTRUCTION
In compliance with
INTERNATIONAL STANDARDS REQUIREMENTS
PERFORMANCES REQUIRED
RELIABILITY REQUIRED
Minimize with our help your Time To Market !
Elica TechLab opens its doors
3. Elica TechLab
SMT&CTDP Laboratory
Design according to
UNI EN/IEC UL ISO 17025
UNI EN/IEC ISO 17025
Testing
Safety Tests (EN/IEC 60335-1; EN/IEC 60335-2-31; UL507; UL1004; CSA C22.2 n属113)
Tests on Non Metallic Materials
Efficiency Tests & Power Consumption Test
Reliability Tests on Components, Materials and Final Products
Packaging Tests & Packaging Materials Qualification
Noise & Performance Tests
EMC tests
Full Qualification of Electronic Components (Reliability tests, Compliance to International
Standards)
Testing according Customers requirements
Elica TechLab opens its doors
4. Elica TechLab
SMT&CTDP Laboratory
Design according to
UNI EN/IEC UL ISO 17025
UNI EN/IEC ISO 17025
Testing : Safety Tests
In-house construction review and testing according to the following standards
IEC / EN 60335-1
IEC / EN 60335-2-31
UL 507
UL 1004
CSA C22.2 n属 113
More than 100 different tests including (for complete list contact us!):
Temperatures tests on components and final products
Windings temperatures evaluations
Grounding Continuity evaluation
Electronic components breakdown
Abnormal tests on transformers, motors, switches
Products behavior when subjected to serious electromagnetic interferences
(lightening, discharges, impulses, radio waves, etc..)
More
Elica TechLab opens its doors
5. Elica TechLab
SMT&CTDP Laboratory
Design according to
UNI EN/IEC UL ISO 17025
UNI EN/IEC ISO 17025
Testing : Tests on Non Metallic Materials
Resistance to fire: glow wire, needle flame, etc
Resistance to high temperatures: glow wire, ball pressure , etc
Resistance to low temperatures: ball impact , etc
Insulation properties: leakage current, dielectric strength, etc..
Mechanical properties: impact tests (hammer, ball), stresses in critical
climatic conditions (mold stress) etc...
Elica TechLab opens its doors
6. Elica TechLab
SMT&CTDP Laboratory
Design according to
UNI EN/IEC UL ISO 17025
UNI EN/IEC ISO 17025
Testing : Efficiency Tests & Power Consumption Test
Energy efficiency evaluation
Evaluation of energy consumption vs. product performances
Power quality measurement
Evaluation of the Stand-by and Off-mode power consumption according
to EC regulation N属 1275/2008 and IEC 62301
Elica TechLab opens its doors
7. Elica TechLab
SMT&CTDP Laboratory
Design according to
UNI EN/IEC UL ISO 17025
UNI EN/IEC ISO 17025
Testing : Reliability Tests on Components, Materials and Final Products
Simulation of environmental conditions (-40属C歎 +180属C / 0 歎 98% RH)
Salt Spray Test (many standards)
Life test of final product and/or components (customers standard)
Elica TechLab opens its doors
8. Elica TechLab
SMT&CTDP Laboratory
Design according to
UNI EN/IEC UL ISO 17025
UNI EN/IEC ISO 17025
Testing : Packaging Tests & Packaging Materials Qualification
Compression test
Clamping test
Free Drop test
Inclined Plane
Vibration test
Trolley test
COBB test
ECT test
Each test can be performed according to
international standards and/or customers
requirements
Elica TechLab opens its doors
9. Elica TechLab
SMT&CTDP Laboratory
Design according to
UNI EN/IEC UL ISO 17025
UNI EN/IEC ISO 17025
Testing : Noise & Performance Tests
Noise Test in Reverberant Room - EN/IEC 60704-1 & HVI 915
Acoustic Holography
Measurement of sound absorption in a reverberation room - ISO 354
Elica TechLab opens its doors
10. Elica TechLab
SMT&CTDP Laboratory
Design according to
UNI EN/IEC UL ISO 17025
UNI EN/IEC ISO 17025
Testing : Noise & Performance Tests
Air Flow Test up to 3000 m3/h - EN/IEC 61591 & HVI 916
Lux Test - EN /IEC 61591
Grease Efficiency Test - EN/IEC 61591
Odour Efficiency Test - EN /IEC 61591
Elica TechLab opens its doors
11. Elica TechLab
SMT&CTDP Laboratory
Design according to
UNI EN/IEC UL ISO 17025
UNI EN/IEC ISO 17025
Testing : EMC Test
ESD EN/IEC 61000-4-2
EFT/Burst EN/IEC 61000-4-4
Surge EN/IEC 61000-4-5
Injected Currents EN/IEC 61000-4-6
Voltage Dips EN/IEC 61000-4-11
Harmonics & Flickers EN/IEC 61000-3-2 & 3-3
Inter-harmonics EN/IEC 61000-4-13
EMF EN/IEC 62233 (ex EN 50366)
Ring Wave ANSI C 62.41
Tests according customers requirements
Elica TechLab opens its doors
12. Elica TechLab
SMT&CTDP Laboratory
Design according to
UNI EN/IEC UL ISO 17025
UNI EN/IEC ISO 17025
Testing : Full Qualification of Electronic Components
Power Electronics
Generation and measurement of high power
signals up to 5 kHz
Signal Levels
Measurement of signals up to 1 GHz
Reliability Test with Automatic Cycles into
climatic chamber
Analysis of the compliance to international
standard
Construction
Materials & components
Normal & abnormal operation tests
Elica TechLab opens its doors
13. Elica TechLab
SMT&CTDP Laboratory
Design according to
UNI EN/IEC UL ISO 17025
UNI EN/IEC ISO 17025
Testing : Testing according Customers requirements
Elica TechLab
is available
to perform each kind of test
according to Special Customers Requirements!
Elica TechLab opens its doors
14. Elica TechLab
SMT&CTDP Laboratory
Design according to
UNI EN/IEC UL ISO 17025
UNI EN/IEC ISO 17025
Approvals
Full verification of the compliance of the product/component to European Standards
Issue of CE Technical Dossier
Full support to get
CB Certificate
National Voluntary Marks for all Countries
UL Mark for USA & Canada
Elica TechLab opens its doors
15. Elica TechLab
SMT&CTDP Laboratory
Design according to
UNI EN/IEC UL ISO 17025
UNI EN/IEC ISO 17025
Contact us and Discover Our Global Services !
Do not hesitate to contact us
for each kind of request or information !
Elica TechLab
e-mail: info@elicatechlab.com
phone: +39 0731 8801 604
Elica TechLab opens its doors