際際滷

際際滷Share a Scribd company logo
CCTV Wiring Solution Design
      Reducing your CCTV Wiring costs
Vision Statement
To reduce cost of wiring in Analog based CCTV by
  Using Video Ballon Instead of Standard Cable
        thereby reducing total project cost
Goal and Objective
   It has been seen Wiring cost is approximately 30-35% of the total
    project
   We plan to reduce the wiring cost by 70% by using this technology
   Less Wiring Means Less Installation Time
   Less Wiring Means Less Maintenance Issue
   Less Wiring means Less utilization of Power
   Replacement of BNC Connector by RJ 45 Crimps
   Elimination of BNC Connector means less service issue.
Standard Wiring Solution

 Given Below is the diagram for standard CCTV wiring solution
How to Save CCTV project costs
Video Ballon Wiring Solution


Given Below is the diagram for Video Ballon CCTV wiring solution
How to Save CCTV project costs
CASE STUDIES
   Let us consider a building with 4 floor of 50 x 50
    meter and a height of 3 meter for each floor
   Each floor has an average of 4 camera with
    monitoring in ground floor.
   Average wiring inside each floor for each camera
    is consider 60 meter
CALCULATION FOR STANDARD CONNECTION
   Ground Floor  60 x 4 = 240 meter
   First Floor  60 x 4 + 4 x 3 = 252 meter
   Second Floor  60 x 4 + 4 x 6 = 264 meter
   Third floor  60 x 4 + 4 x 9 = 276 meter

   Total wiring = 960 x 2 + 72 x 2 = 2064 meter
   Plus PVC conduit of 2064 meter
CALCULATION FOR UTP BALLON CONNECTION
In this case we strategically place the passive receiver in such a way that
Our average wiring comes to 35 meter per floor
   Ground Floor  35 x 4 = 140 meter
   First Floor  35 x 4 + 1 x 4 = 144 meter
   Second Floor  35 x 4 + 1 x 8 = 148 meter
   Third floor  35 x 4 + 1 x 14 = 154 meter

   Total wiring = 960 x 2 + 72 x 2 = 586 meter
   Plus PVC conduit of 586 meter
Conclusion

From previous illustration its clear that wiring was
reduced by 72%. This effects the following:

a) Total Project Costing
b) Installation Time
c) System Down Time
Thank You


For any further details, you can contact:

JimuthDutta
jimuth@vyteq.com
98-71211466

More Related Content

How to Save CCTV project costs

  • 1. CCTV Wiring Solution Design Reducing your CCTV Wiring costs
  • 2. Vision Statement To reduce cost of wiring in Analog based CCTV by Using Video Ballon Instead of Standard Cable thereby reducing total project cost
  • 3. Goal and Objective It has been seen Wiring cost is approximately 30-35% of the total project We plan to reduce the wiring cost by 70% by using this technology Less Wiring Means Less Installation Time Less Wiring Means Less Maintenance Issue Less Wiring means Less utilization of Power Replacement of BNC Connector by RJ 45 Crimps Elimination of BNC Connector means less service issue.
  • 4. Standard Wiring Solution Given Below is the diagram for standard CCTV wiring solution
  • 6. Video Ballon Wiring Solution Given Below is the diagram for Video Ballon CCTV wiring solution
  • 8. CASE STUDIES Let us consider a building with 4 floor of 50 x 50 meter and a height of 3 meter for each floor Each floor has an average of 4 camera with monitoring in ground floor. Average wiring inside each floor for each camera is consider 60 meter
  • 9. CALCULATION FOR STANDARD CONNECTION Ground Floor 60 x 4 = 240 meter First Floor 60 x 4 + 4 x 3 = 252 meter Second Floor 60 x 4 + 4 x 6 = 264 meter Third floor 60 x 4 + 4 x 9 = 276 meter Total wiring = 960 x 2 + 72 x 2 = 2064 meter Plus PVC conduit of 2064 meter
  • 10. CALCULATION FOR UTP BALLON CONNECTION In this case we strategically place the passive receiver in such a way that Our average wiring comes to 35 meter per floor Ground Floor 35 x 4 = 140 meter First Floor 35 x 4 + 1 x 4 = 144 meter Second Floor 35 x 4 + 1 x 8 = 148 meter Third floor 35 x 4 + 1 x 14 = 154 meter Total wiring = 960 x 2 + 72 x 2 = 586 meter Plus PVC conduit of 586 meter
  • 11. Conclusion From previous illustration its clear that wiring was reduced by 72%. This effects the following: a) Total Project Costing b) Installation Time c) System Down Time
  • 12. Thank You For any further details, you can contact: JimuthDutta jimuth@vyteq.com 98-71211466