Installation of a CHT probe is amazing simple and, in this article, we show you how
to do it yourself.
You begin with installing the CHT probe in the rear spark plug of both the front and
rear cylinder so the cylinder head probe is going to go in the aft plug with the plug
closest to the rear of the airplane in both the front cylinder and the rear cylinder.
Start with taking out the spark plug. With the
spark plug out, we recommend application of
a little bit of anti-seize compound on the
threads. With the spark plug out you should
notice the presence of a compression washer 
make sure it stays there. There will also be a
rubber grommet or gasket that will come out
of the shroud on the engine  dont forget to
that back as it seals off the spark plug and
prevents moisture and dust from entering.
You might also have a drill a small hole on the
engine shroud and pass the CHT probe wire
through it otherwise fitting the sparkplug cap
would be almost impossible (and might
damage the probe wire).
Seat the CHT probe on the spark plug and then
bend the probe upwards so the wire will be facing upwards when you re-fix the
sparkplug. Initially tighten the spark plug by hand and then by tool. Finally, gently
push the rubber grommet / gasket into place. You might have to use a blunt tool like
a screw driver to fix the gasket into place.
Once you re-installed the spark plug and gasket in place, you will need to clamp the
CHT probe wire in place so that it does not flap around in the wind or touch
something hot which might result in wrong data being fed into your CHT display
unit / EDM.
Now, in the event you need to extend the CHT probe wire do the following:
1. Strip the ends of CHT probe wires and make small loops at the ends.
2. Repeat this process with the type-K extension wire (if they too have to be
extended).
3. Prepare the splice barrels and heat shrink.
4. Pass the wire through the splice barrel and heat shrink tube.
5. Lay the CHT Probes and type-K extension loops over each other.
6. 際際滷 the splice barrel over the parallel loops.
7. Crimp the splice barrel with a crimping tool (use a crimping tool with a grip
for non-insulated terminals the ones that have a cradle on one side and
pierce a small hole on the other).
8. 際際滷 the heat shrink over the splice and heat with a heat gun or lighter.
9. If you followed the above steps, you should now have a perfect thermocouple
splice.
More information at: https://www.jpinstruments.com/shop/cht-probe-
4-pack/
JPI Sales:
1-800-345-4574
714-557-3805
FAX: 714-557-9840
sales@jpinstruments.com
JPI Technical Support:
1-800-345-4574
714-557-3805
support@jpinstruments.com
J.P. Instruments Inc.
3185-B Airway Ave
Costa Mesa, CA 92626 U.S.A

More Related Content

Installation of cylinder head temperature probe

  • 1. Installation of a CHT probe is amazing simple and, in this article, we show you how to do it yourself. You begin with installing the CHT probe in the rear spark plug of both the front and rear cylinder so the cylinder head probe is going to go in the aft plug with the plug closest to the rear of the airplane in both the front cylinder and the rear cylinder. Start with taking out the spark plug. With the spark plug out, we recommend application of a little bit of anti-seize compound on the threads. With the spark plug out you should notice the presence of a compression washer make sure it stays there. There will also be a rubber grommet or gasket that will come out of the shroud on the engine dont forget to that back as it seals off the spark plug and prevents moisture and dust from entering. You might also have a drill a small hole on the engine shroud and pass the CHT probe wire through it otherwise fitting the sparkplug cap would be almost impossible (and might damage the probe wire). Seat the CHT probe on the spark plug and then bend the probe upwards so the wire will be facing upwards when you re-fix the sparkplug. Initially tighten the spark plug by hand and then by tool. Finally, gently push the rubber grommet / gasket into place. You might have to use a blunt tool like a screw driver to fix the gasket into place.
  • 2. Once you re-installed the spark plug and gasket in place, you will need to clamp the CHT probe wire in place so that it does not flap around in the wind or touch something hot which might result in wrong data being fed into your CHT display unit / EDM. Now, in the event you need to extend the CHT probe wire do the following: 1. Strip the ends of CHT probe wires and make small loops at the ends. 2. Repeat this process with the type-K extension wire (if they too have to be extended). 3. Prepare the splice barrels and heat shrink. 4. Pass the wire through the splice barrel and heat shrink tube. 5. Lay the CHT Probes and type-K extension loops over each other. 6. 際際滷 the splice barrel over the parallel loops. 7. Crimp the splice barrel with a crimping tool (use a crimping tool with a grip for non-insulated terminals the ones that have a cradle on one side and pierce a small hole on the other). 8. 際際滷 the heat shrink over the splice and heat with a heat gun or lighter. 9. If you followed the above steps, you should now have a perfect thermocouple splice. More information at: https://www.jpinstruments.com/shop/cht-probe- 4-pack/ JPI Sales: 1-800-345-4574 714-557-3805 FAX: 714-557-9840 sales@jpinstruments.com JPI Technical Support: 1-800-345-4574 714-557-3805 support@jpinstruments.com J.P. Instruments Inc. 3185-B Airway Ave Costa Mesa, CA 92626 U.S.A