ݺߣ

ݺߣShare a Scribd company logo
Class B+C/ Type I+II Single Phase
JMV/B+C/# NPE:
Class B+C surge protection devices offer
solution with combined performance over
8/20 µs and 10/350 µs waveform to
withstand against lightning and switching
surges. These Surge protectors are also used
for the protection of single & three phase
lines but the combined protection declares
them as the upgraded version of its range. Class
B+C surge arresters are dedicatedly known as
Type I+II lightning cum switching surge protection
devices which are acknowledged for its dual protection in
the vicinity of LPZ0-2.
Model JMV/B+C/1 NPE JMV/B+C/3 NPE
Housing material PA
Number of Modules
Degree of protection
Ambient temperature (operation)
2 4
IP20
Mounting type DIN rail: 35 mm
-40 °C ... 80 °C
Nominal voltage UN
230 V AC (230/400 V AC ... 240/415 V AC)
Arrester rated voltage UC
320 V AC (L-N), 255 V AC (N-PE)
Nominal frequency fN
Lightning test current (10/350) µs, peak value limp
Protection Level
50 Hz
25 kA
Nominal discharge surge current In (8/20) µs 30 kA (L-N); 30 kA (N-PE)
0.9 kV (L-N); 1.3 kV (N-PE)
Response Time ≤ 25 ns (L-N ); ≤ 100 ns (N-PE)
Remote Signalling
Connection Type Biconnect terminal block
Yes
Indicator Yes
Pluggable Yes
Standards 61643-11
JMV LPS LIMITED
ACPOWERSURGEPROTECTIONDEVICES
W-50, Sector-11, Noida 201301, India
www.jmv.co.in info@jmv.co.in

More Related Content

JMV’s proficiently developed Class B+C Surge protection Devices

  • 1. Class B+C/ Type I+II Single Phase JMV/B+C/# NPE: Class B+C surge protection devices offer solution with combined performance over 8/20 µs and 10/350 µs waveform to withstand against lightning and switching surges. These Surge protectors are also used for the protection of single & three phase lines but the combined protection declares them as the upgraded version of its range. Class B+C surge arresters are dedicatedly known as Type I+II lightning cum switching surge protection devices which are acknowledged for its dual protection in the vicinity of LPZ0-2. Model JMV/B+C/1 NPE JMV/B+C/3 NPE Housing material PA Number of Modules Degree of protection Ambient temperature (operation) 2 4 IP20 Mounting type DIN rail: 35 mm -40 °C ... 80 °C Nominal voltage UN 230 V AC (230/400 V AC ... 240/415 V AC) Arrester rated voltage UC 320 V AC (L-N), 255 V AC (N-PE) Nominal frequency fN Lightning test current (10/350) µs, peak value limp Protection Level 50 Hz 25 kA Nominal discharge surge current In (8/20) µs 30 kA (L-N); 30 kA (N-PE) 0.9 kV (L-N); 1.3 kV (N-PE) Response Time ≤ 25 ns (L-N ); ≤ 100 ns (N-PE) Remote Signalling Connection Type Biconnect terminal block Yes Indicator Yes Pluggable Yes Standards 61643-11 JMV LPS LIMITED ACPOWERSURGEPROTECTIONDEVICES W-50, Sector-11, Noida 201301, India www.jmv.co.in info@jmv.co.in