際際滷

際際滷Share a Scribd company logo
1 Kitchen Staff Toilets
2 Dish & Pot Wash 168 SQ Ft
3 Daily Kitchen Store 120 Sq Ft
4 Clearance Passage
5 Wet Corner 72 Sq Ft
6 6 Potato & Onion 12 Sq Ft
7 Chef Cabin 36 Sq Ft
8 Service Passage
9 9 Pickup Counter 2 Ft X 16 Ft
10 Indian 80 sq ft
11 Tandoor 100 sq ft
12 Fast Food 120 Sq Ft
13 Continental 100 sq ft
14 Chinese 100 sq ft
15 Bakery 80 sq ft
16 Garde Manger 64 Sq Ft
17 Pantry 64 Sq Ft
PROPOSED KITCHEN SECTIONS
10
11 12 13 14
15
16
17
7
1
2 3
4 5
8
Kitchen Drain Line - Concealed
4 Inch Lower Than Kitchen Floor Floor Level
Floor AT kitchen Floor Level
Removable Exit Cum Openable Drain Line Points
2 Inch Lower Than Kitchen Floor Floor Level
FIRST EXIT POINT FROM KITCHEN TO HAVE GREASE
COLLECTION TANK
PROPOSED KITCHEN FLOOR DRAINAGE SECTIONS
Dish & Pot Wash
Daily Kitchen Store
Wet Corner
6
9
Wash basin With Tap at 4 Ft
Water Taps at 4 Ft Height
PROPOSED KITCHEN PLUMBING SECTION
10 15
17 16
11 12 13 14
1
2 3
4 5
8 7
6
9
1
3
Kitchen Exhaust & AHU Control
Light Control Switches with addtl 6 AMP Sockets
PROPOSED KITCHEN ELECTRICAL POINTS
All Electrical Line will run at 5 Ft Height From Floor Level
Single Tubelights
Panel Lights
Industrial Socket Points
5 6
7
Treated Fresh Air Duct
Kitchen Exhaust Duct
Exhaust Hoods
PROPOSED DUCTING SECTIONS
1
2 3
4
8
Gas Point Connection
Gas Line
1
2 3
PROPOSED KITCHEN GAS LINE

More Related Content

Kitchen Design.pdf

  • 1. 1 Kitchen Staff Toilets 2 Dish & Pot Wash 168 SQ Ft 3 Daily Kitchen Store 120 Sq Ft 4 Clearance Passage 5 Wet Corner 72 Sq Ft 6 6 Potato & Onion 12 Sq Ft 7 Chef Cabin 36 Sq Ft 8 Service Passage 9 9 Pickup Counter 2 Ft X 16 Ft 10 Indian 80 sq ft 11 Tandoor 100 sq ft 12 Fast Food 120 Sq Ft 13 Continental 100 sq ft 14 Chinese 100 sq ft 15 Bakery 80 sq ft 16 Garde Manger 64 Sq Ft 17 Pantry 64 Sq Ft PROPOSED KITCHEN SECTIONS 10 11 12 13 14 15 16 17 7 1 2 3 4 5 8
  • 2. Kitchen Drain Line - Concealed 4 Inch Lower Than Kitchen Floor Floor Level Floor AT kitchen Floor Level Removable Exit Cum Openable Drain Line Points 2 Inch Lower Than Kitchen Floor Floor Level FIRST EXIT POINT FROM KITCHEN TO HAVE GREASE COLLECTION TANK PROPOSED KITCHEN FLOOR DRAINAGE SECTIONS Dish & Pot Wash Daily Kitchen Store Wet Corner
  • 3. 6 9 Wash basin With Tap at 4 Ft Water Taps at 4 Ft Height PROPOSED KITCHEN PLUMBING SECTION 10 15 17 16 11 12 13 14 1 2 3 4 5 8 7
  • 4. 6 9 1 3 Kitchen Exhaust & AHU Control Light Control Switches with addtl 6 AMP Sockets PROPOSED KITCHEN ELECTRICAL POINTS All Electrical Line will run at 5 Ft Height From Floor Level Single Tubelights Panel Lights Industrial Socket Points
  • 5. 5 6 7 Treated Fresh Air Duct Kitchen Exhaust Duct Exhaust Hoods PROPOSED DUCTING SECTIONS 1 2 3 4 8
  • 6. Gas Point Connection Gas Line 1 2 3 PROPOSED KITCHEN GAS LINE