1) The document discusses food safety and chain management, outlining a traditional production-oriented approach versus a consumer and market-oriented chain management approach.
2) It then summarizes EU policy on food safety, which aims to ensure stable supply of safe, quality food through harmonized standards while also supporting rural communities.
3) New developments in the Netherlands are highlighted, including reduced pesticide use through certification and training, and innovation in greenhouse technology, biological controls, and cooperative organizations.
Dacom provides agri yield management solutions using sensor technology and models to optimize crop yields and reduce costs like water and fungicide usage. Their solutions include weather stations, sensors, and apps that provide irrigation and disease control advice. One project in South Africa helped small farmers optimize chemical use and yields using text message advisories. Dacom has many partners and develops their own biological models to determine infection risks and provide nationwide warning systems to thousands of farmers.
1) The document discusses food safety and chain management, outlining a traditional production-oriented approach versus a consumer and market-oriented chain management approach.
2) It then summarizes EU policy on food safety, which aims to ensure stable supply of safe, quality food through harmonized standards while also supporting rural communities.
3) New developments in the Netherlands are highlighted, including reduced pesticide use through certification and training, and innovation in greenhouse technology, biological controls, and cooperative organizations.
Dacom provides agri yield management solutions using sensor technology and models to optimize crop yields and reduce costs like water and fungicide usage. Their solutions include weather stations, sensors, and apps that provide irrigation and disease control advice. One project in South Africa helped small farmers optimize chemical use and yields using text message advisories. Dacom has many partners and develops their own biological models to determine infection risks and provide nationwide warning systems to thousands of farmers.
1. KONTROLNO TESTIRANJE
PRSKALICA I OROIVAA
Dr Aleksandar Sedlar
Dr Rajko Bugarin
UNIVERZITET U NOVOM SADU
POLJOPRIVREDNI FAKULTET
DEPARTMAN ZA POLJOPRIVREDNU
TEHNIKU
Laboratorija za kontrolu tehnike za
aplikaciju pesticida (LTAP)
2. Inspekcija prskalica i oro邸ivaa THE FRAMEWORK DIRECTIVE ON THE SUSTAINABLE USE OF PESTICIDES
(EU 128/2009)
Amendment of Machinery Directive (EU 127/2009)
EN 13790
EN 12761
Zakon o sredstvima za za邸titu bilja R. Srbije
Komercijalni standardi i procedure Globalgap, ISCC...
3. KONTROLNO TESTIRANJE PRSKALICA
Pre poetka inspekcije treba prskalicu i sve njene delove dobro isprati, a zatim izvr邸iti
tzv. grubu kontrolu prskalice.
Cilj navedenog je da se ne kontroli邸e ne邸to 邸to je vidljivo neispravno.
ta je predmet kontrole pri inspekciji prskalica?
4. Proveriti vidljivost pokazivaa nivoa tenosti u rezervoaru?
Pokaziva nivoa mora biti precizan i jasno vidljiv iz kabine traktora i sa mesta
sipanja tenosti u rezervoar.
Lo邸e Dobro
5. Proveriti stanje filtere?
Prskalica mora imati obavezno jedno filtrirajue mesto pre ulaska tenosti u pumpu
i jedno posle izlaska, a da se pri tome ne rauna filter rasprskivaa.
Dobar filter
6. ta se proverava kod prskajuih krila?
Proveriti stabilnost krila u horizontali i verikali, a po potrebi i ispravnost taster dela krila.
7. Proveriti polo転aj rasprskivaa na krilu i udaljenost vrha rasprskivaa od povr邸ine
Polo転aj mora biti jednak kako bi se dobilo dobro preklapnje mlazeva i ravnomerna
poprena distribucija pesticida po tretiranom objektu.
Udaljenost vrha rasprskivaa od povr邸ine ne sme da bude vea od 10 cm u odnosu na
prosenu udaljenost ili 1 % u odnosu na polovinu radnog zahvata.
< 10 cm/ 1 %
8. Prekontrolisati stanje i ispravnost svih upravljakih elemenata
(ventila sekcija, merila protoka, regulatora pritiska).
Prekontrolisati vidljivost elektronskog displeja (ako postoji) i dati predlog najboljeg
polo転aja za njega sa aspekta vidljivosti i pristupanosti.
9. Stanje, polo転aj i privr邸enost KV. Stanje za邸titne obloge KV.
Broj obrtaja PV 540 o/min.
Nije dobro Dobro
10. Kako proveriti da li vodovi i creva cure?
Ukljuiti prskalicu da radi sa maksimalnim pritiskom i zatim vizuelno prekontrolisati
sve vodove i creva.
11. Proveriti funkcionalnost svih ventila sekcija, proveriti uniformnost
rasprskivaa i proveriti funkcionisanje antidrop ureaja.
5 sekundi posle prskanja ne sme biti nikakvog kapanja.
12. ta se testira ?
-Pumpa
-Rasprskivai
-Manometar
-Me邸a
- Provera pumpe
Radni opseg 5 400 l/min
Pritisak do 25 bar
Prvo proveriti da li pumpa svojim tehnikim karakteristikama odgovara
prskalici, a zatim i njen protok pomou testera pumpe.
Q = 1.1 x n x q + (5-10% V)
13. Proveriti protok pumpe?
Protok pumpe ne sme da se menja sa promenom pritiska.
Protok pumpe mora da iznosi 90 % od njenog fabrikog nominalnog kapaciteta,
odnosno pumpa mora da obezbedi dovoljno tenosti pri radu prskalice sa najveim
predvienim rasprskivaima i pritiskom.
14. Prenik manometra mora biti minimum 63 mm.
63 mm
Manotest
Kakvo treba da bude merilo pritiska?
15. Merilo pritiska treba da bude isto sa jasno vidljivom skalom.
Skala treba da bude:
do 5 bar 0.2 bar
5 20 bar 1.0 bar
Preko 20 bar 2.0 bar
Nije dobro
Dobro
16. Preciznost manometra mora biti u granicama 賊 0.2 bar, pri radu sa pritiscima do 2 bar.
Pri radu sa pritiscima preko 2 bar dozvoljeno odstupanje je 賊 10 %.
Mehaniki tester manometra
Elektronski tester manometra
18. Kontrola rasprskivaa
Kada treba zameniti rasprskivae?
- kada im se protok proveao za vi邸e od 15 %
- kada ime je CV poprene distribucije vei od 10 %
24. INSPEKCIJA OROIVAA
Inspekcija oro邸ivaa se sprovodi u skladu sa EN 13 790
EN 13790 Agricultural machinery Sprayers Inspection of sparyers in use
Part 1: Field crop sprayers
Part 2: Air-assisted sprayers for bush and tree crops
Vizuelno kontrole, provera kapaciteta pumpe i manotest kao kod
inspekcije prskalice.
25. Uporediti vrednost pritiska na manometru i na obe strane venca rasprskivaa.
Razlika izmeu pritisaka na sme biti vea od 15 %.
15%