際際滷

際際滷Share a Scribd company logo
MR SERIES: LED Light Bar 
MR-1100-318-ALC 
2 x 4 
INSTALLATION INSTRUCTIONS 
IMPORTANT SAFEGUARDS 
When using electrical equipment, basic safety precautions should always be followed including the following below: 
READ AND FOLLOW ALL SAFETY INSTRUCTIONS 
1. DANGER  RISK OF SHOCK  DISCONNECT POWER BEFORE INSTALLATION 
2. WARNING  Risk of fire or electric shock. LED lighting upgrade kit installation requires knowledge of luminaires electrical systems. If you 
are not qualified, do not attempt installation. Product must be installed in accordance with NEC or your local, state, or federal electrical 
codes. If you are not familiar with these codes and requirements, contact a qualified electrician. 
3. WARNING  Risk of fire or electric shock. Luminaries wiring and electrical parts may be damaged when drilling for installation of 
the LED lighting upgrade kit. Check for enclosed wiring and components before installation. 
4. WARNING  Risk of fire or electric shock. Check the existing wiring for damage before installing Led lighting upgrade kit. Do not install 
Led upgrade kit if existing wires are damaged in anyway. 
5. WARNING  To prevent wiring damage or abrasion, do not expose electrical wires to the edge of sheet metal and/or any other sharp 
objects. 
6. WARNING  Risk of fire or electric shock. Install this kit only in the luminaries that have the construction features and 
dimensions shown in the photographs and/or drawings listed below or on the attached sheets. 
7. Do not make or alter any holes in a wiring enclosure or electrical components during the kit installation. 
8. Only the holes indicated in the photographs and/or drawings may be made or altered as a result of the led lighting upgrade kit installation. 
Do not leave any other holes open in a wiring enclosure or electrical component. 
PLEASE SAVE THESE INSTRUCTIONS FOR FUTURE USE 
NOTES: 
1. LED light bar upgrade kit is for installation in a 2x4 luminarie with the following minimum dimensions: 
 2-15/16deep pan 
 3wide minimum wiring compartment 
 44minimum length to accommodate LED light bars 
 Only ONE kit is to be installed per luminaire 
2. Please consult your local authority regarding disposal and/or recycling of removed ballast and lamps. 
1 of 4 
Upgrade Kit contains the following parts: 
(3) LED light bars 
(1) LED Driver 
(6) #6 Self taping screws 
(2) #8 Driver mounting screws 
(1) LED retrofit relamping label
HOW TO INSTALL OUR LED LIGHT BAR UPGRADE KIT MR-1100-318-ALC IN A 2x4 Luminarie. 
STEP 1: Turn off the power 
As stated previously, turn off the power. 
Locate latches on the lens frame and release 
them allowing lens frame to swing open. 
Carefully let lens frame hang and remove if 
obstructing upgrade. 
STEP 2: REMOVE THE TUBES 
Remove the existing linear fluorescent tubes 
and properly dispose of them. See Figure 2. 
NOTE: Please seek advice from the EPA at 
their website, local office, or national hotline 
for further disposal details for fluorescent 
tubes. The EPA's website is www.EPA.gov 
STEP 3: REMOVE BALLAST COVER 
To remove the wiring and ballast cover, squeeze the 
sides in and pull down and set aside. See Figure 3. 
STEP 4: UNSCREW BALLAST 
Find the existing ballast and remove the screw 
holding the ballast to the fixture. See Figure 4. 
STEP 5: REMOVE LEADS & BALLAST 
Now remove the ballast from the fixture by cutting 
the leads from the ballast to the fixture on both 
ends of the luminaire and cap the socket leads. 
See Figure 5. 
NOTE: When cutting leads to the fixture, always 
leave the smallest amount of wire attached. 
1 
2 
3 
4 5 
2 of 4
6 7 
STEP 6: CUT POWER LEADS 
Cut or disconnect the leads from the ballast to 
the input power ensuring that you leave as 
much length of wire as possible for the 
electrical connections. Remove the ballast from 
housing and dispose of properly. See Figure 6 
STEP 7: PREP WIRES 
Prepare input power by stripping input power 
leads 村 inch. See Figure 7 
STEP 8 / 8A: STRIP & ATTACH TO DRIVER 
Prepare input power by stripping input power leads 村 
inch. Connect driver to input leads. 
See Figure 8 / 8A. 
STEP 9: ATTACH DRIVER 
Bring new driver into fixture using mounting holes 
from old ballast if possible and secure it using 
supplied #8-32 screw. See Figure 9. 
NOTE: If housing has multiple locations for power 
supply, new driver can be secured in any of these 
locations. 
STEP 10: Connect Driver to input power 
Make electrical connection per Electrical 
Connections per section on page 4. 
STEP 11: ATTACH DRIVER COVER 
Bring wiring / driver (ballast) cover previously 
removed in Step 3 into the fixture. Carefully 
tuck all leads and wire connectors into the wire 
compartment area of the fixture. Reattach 
cover by snapping into place over driver, do 
not pinch wires. See Figure 10. 
8 8A 
9 
10 
3 of 4 
HOW TO INSTALL OUR LED LIGHT BAR UPGRADE KIT MR-1100-318-ALC IN A 2x4 Luminarie.
ELECTRICAL CONNECTIONS 
Make the following Electrical 
Connections: See Figure 15 
a. Connect the BROWN driver lead 
to the black voltage supply wire. 
b. Connect the BLUE driver lead to 
the WHITE neutral supply wire. 
c. Ground the GREEN wire to the 
fixture. 
4 of 4 
BLACK 
WHITE 
GREEN 
LINE 
NEUTRAL 
STEP 12: Peel blue film from tape 
Prior to installing light bar make sure the 
fixture is clean of dirt and/or debris. After 
wiping down fixture make sure it is dry 
before installing light bar. Remove blue 
protective film from the 3M adhesive heat 
sink tape from the back of Led light bar. 
See Figure 11. 
STEP 13: INSTALL LIGHT BAR 
Install the LED light bar into the fixture. 
Repeat this step for each LED light bar 
supplied in the LED light bar upgrade kit. 
STEP 14: SECURE THEM IN 
Once all LED light bars are in desired 
position permanently secure them to 
fixture by inserting (2) supplied self 
tapping screws into each end of the 
LED Light bar. See Figure 12. 
STEP 15: 
Connect the driver lead connector, that 
is exposed at the end of the driver 
compartment with the LED 
Light bar connector. See Figure 13. 
NOTE: Place the LED relamp label, 
provided in the kit, on the inside of the 
fixtures lighting compartment. Always 
make sure that the label is visible. 
STEP 16: Close & turn on 
Close the fixtures door and secure the 
latches prior to turning on the upgrade 
kit added to your fixture. 
See Figure 14. 
11 
12 
BROWN 
BLUE 
GROUND 
DRIVER ASSEMBLY 
15 
14 
13

More Related Content

M lite mr-series-led-upgrade-kit-installation-instructions 3 led light bars mr-1100-318-alc

  • 1. MR SERIES: LED Light Bar MR-1100-318-ALC 2 x 4 INSTALLATION INSTRUCTIONS IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following below: READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION 2. WARNING Risk of fire or electric shock. LED lighting upgrade kit installation requires knowledge of luminaires electrical systems. If you are not qualified, do not attempt installation. Product must be installed in accordance with NEC or your local, state, or federal electrical codes. If you are not familiar with these codes and requirements, contact a qualified electrician. 3. WARNING Risk of fire or electric shock. Luminaries wiring and electrical parts may be damaged when drilling for installation of the LED lighting upgrade kit. Check for enclosed wiring and components before installation. 4. WARNING Risk of fire or electric shock. Check the existing wiring for damage before installing Led lighting upgrade kit. Do not install Led upgrade kit if existing wires are damaged in anyway. 5. WARNING To prevent wiring damage or abrasion, do not expose electrical wires to the edge of sheet metal and/or any other sharp objects. 6. WARNING Risk of fire or electric shock. Install this kit only in the luminaries that have the construction features and dimensions shown in the photographs and/or drawings listed below or on the attached sheets. 7. Do not make or alter any holes in a wiring enclosure or electrical components during the kit installation. 8. Only the holes indicated in the photographs and/or drawings may be made or altered as a result of the led lighting upgrade kit installation. Do not leave any other holes open in a wiring enclosure or electrical component. PLEASE SAVE THESE INSTRUCTIONS FOR FUTURE USE NOTES: 1. LED light bar upgrade kit is for installation in a 2x4 luminarie with the following minimum dimensions: 2-15/16deep pan 3wide minimum wiring compartment 44minimum length to accommodate LED light bars Only ONE kit is to be installed per luminaire 2. Please consult your local authority regarding disposal and/or recycling of removed ballast and lamps. 1 of 4 Upgrade Kit contains the following parts: (3) LED light bars (1) LED Driver (6) #6 Self taping screws (2) #8 Driver mounting screws (1) LED retrofit relamping label
  • 2. HOW TO INSTALL OUR LED LIGHT BAR UPGRADE KIT MR-1100-318-ALC IN A 2x4 Luminarie. STEP 1: Turn off the power As stated previously, turn off the power. Locate latches on the lens frame and release them allowing lens frame to swing open. Carefully let lens frame hang and remove if obstructing upgrade. STEP 2: REMOVE THE TUBES Remove the existing linear fluorescent tubes and properly dispose of them. See Figure 2. NOTE: Please seek advice from the EPA at their website, local office, or national hotline for further disposal details for fluorescent tubes. The EPA's website is www.EPA.gov STEP 3: REMOVE BALLAST COVER To remove the wiring and ballast cover, squeeze the sides in and pull down and set aside. See Figure 3. STEP 4: UNSCREW BALLAST Find the existing ballast and remove the screw holding the ballast to the fixture. See Figure 4. STEP 5: REMOVE LEADS & BALLAST Now remove the ballast from the fixture by cutting the leads from the ballast to the fixture on both ends of the luminaire and cap the socket leads. See Figure 5. NOTE: When cutting leads to the fixture, always leave the smallest amount of wire attached. 1 2 3 4 5 2 of 4
  • 3. 6 7 STEP 6: CUT POWER LEADS Cut or disconnect the leads from the ballast to the input power ensuring that you leave as much length of wire as possible for the electrical connections. Remove the ballast from housing and dispose of properly. See Figure 6 STEP 7: PREP WIRES Prepare input power by stripping input power leads 村 inch. See Figure 7 STEP 8 / 8A: STRIP & ATTACH TO DRIVER Prepare input power by stripping input power leads 村 inch. Connect driver to input leads. See Figure 8 / 8A. STEP 9: ATTACH DRIVER Bring new driver into fixture using mounting holes from old ballast if possible and secure it using supplied #8-32 screw. See Figure 9. NOTE: If housing has multiple locations for power supply, new driver can be secured in any of these locations. STEP 10: Connect Driver to input power Make electrical connection per Electrical Connections per section on page 4. STEP 11: ATTACH DRIVER COVER Bring wiring / driver (ballast) cover previously removed in Step 3 into the fixture. Carefully tuck all leads and wire connectors into the wire compartment area of the fixture. Reattach cover by snapping into place over driver, do not pinch wires. See Figure 10. 8 8A 9 10 3 of 4 HOW TO INSTALL OUR LED LIGHT BAR UPGRADE KIT MR-1100-318-ALC IN A 2x4 Luminarie.
  • 4. ELECTRICAL CONNECTIONS Make the following Electrical Connections: See Figure 15 a. Connect the BROWN driver lead to the black voltage supply wire. b. Connect the BLUE driver lead to the WHITE neutral supply wire. c. Ground the GREEN wire to the fixture. 4 of 4 BLACK WHITE GREEN LINE NEUTRAL STEP 12: Peel blue film from tape Prior to installing light bar make sure the fixture is clean of dirt and/or debris. After wiping down fixture make sure it is dry before installing light bar. Remove blue protective film from the 3M adhesive heat sink tape from the back of Led light bar. See Figure 11. STEP 13: INSTALL LIGHT BAR Install the LED light bar into the fixture. Repeat this step for each LED light bar supplied in the LED light bar upgrade kit. STEP 14: SECURE THEM IN Once all LED light bars are in desired position permanently secure them to fixture by inserting (2) supplied self tapping screws into each end of the LED Light bar. See Figure 12. STEP 15: Connect the driver lead connector, that is exposed at the end of the driver compartment with the LED Light bar connector. See Figure 13. NOTE: Place the LED relamp label, provided in the kit, on the inside of the fixtures lighting compartment. Always make sure that the label is visible. STEP 16: Close & turn on Close the fixtures door and secure the latches prior to turning on the upgrade kit added to your fixture. See Figure 14. 11 12 BROWN BLUE GROUND DRIVER ASSEMBLY 15 14 13