This document provides a product guide for INDUSTREX films for industrial x-ray use, listing various film types, their specifications, recommended processing chemicals and conditions. It includes charts specifying films by system class and spectral sensitivity, replacement films from other manufacturers, available formats, recommended developers and fixers, and automatic and manual processing times and temperatures. The document also provides product codes and order numbers for the processing chemicals.
1 of 1
Download to read offline
More Related Content
NDT_Films_Guide-201510.pdf
1. Carestream Health, Inc.
150 Verona Street
Rochester, NY, USA 14608
?Carestream Health, Inc., 2020
Created in the USA
Publication No. CHSP-9006, Rev. 1
CARESTREAM, INDUSTREX, and LANEX are trademarks of Carestream Health.
2020-09-25
INDUSTREX Films for Industrial X-ray Use - Product Guide1
INDUSTREX
Film /
Product Code
System Class2
Notched
Replaces Available Formats (code)
Spectral
Sensitivity
Safelight
Filter
AUTOMATIC Processing
Chemicals
Developer
____
Fixer
Recommended
Starting Points
(Development
Time and
Temperature)
ASTM
E1815
ISO
11699-1
EN
ISO
11699-1
STRUCTURIX
FUJI
Sheets Rolls
Non-interleaved
(1)
Interleavedd
(5)
READY-PACK
II
(2)
PB
Contactpak
(7)
NIF
Rolls
(bulk)
(359)
Lead
Pack
(382)
Ready
Pack
(381)
DR50 / 6536 Special C1 〔 D2 IX25 〔 X-ray
and
visible
blue
light
(Red)
1, 2,
or
GBX-2
DEVELOPER
INDUSTREX Single Part Developer
Replenisher or
INDUSTREX DX Developer7
,
mixed 1:3 w/ H20 Replenishment
Rate: 665 mL/m2
FIXER4
INDUSTREX LO Fixer and
Replenisher or INDUSTREX FX
Fixer7
, mixed 1:3 w/ H20
Replenishment Rate: 1200 mL/m2
AUTOMATIC
8-minute cycle:
100 seconds
@ 26? C (79 ?F)
5-minute cycle:
60 seconds
@ 30 ?C (86 ?F)
MANUAL6
4 minutes
@ 22 ?C (72 ?F)
M100 / 5532 CI C2 〔 D3 IX50 〔 〔 〔 〔 〔 〔
MX125 / 4748 CI C3
See
note 3
D4 IX50 〔 〔 〔 〔 〔 〔 〔
T200 / 6537 CI C4 〔 D5 IX80 〔 〔 〔 〔
AA400 / 5533 CII C5 〔 D7 IX100 〔 〔 〔 〔 〔 〔 〔
HS8005
/ 5747 CIII C6 〔
D8/
F8
IX150 〔 〔 〔
1 Refer to NDT Resources at carestream.com for film and chemistry technical data.
2 Classification applies to INDUSTREX films processed in INDUSTREX chemicals, not the other
manufacturers¨ product they are replacing.
3 INDUSTREX MX125 Film finished in China has a wide trapezoidal notch. MX125 finished in
Mexico has no notch.
4 For optimum archivability, such as required for nuclear applications, a 10 % increase in the fixer
replenishment rate may be desirable. For more information, see CHSP-8999 INDUSTREX Films
Technical Data.
5 INDUSTREX HS800 Film provides high speed and contrast throughout an extended range of
optical densities when used with fluorescent and fluorometallic screens. HS800 is recommended for
use with LANEX Fast Screens, CAT 116 0688 (35 x 43 cm) or CAT 861 9553 (30 x 40 cm).
6 Eliminate guesswork in determining the proper exposure and get more consistent results by using
a smartphone app to help with the calculation of exposure times.
Example smartphone apps: GammaCalc / GammaCalc Pro or X-ray Timer
7 Eco-friendly INDUSTREX DX Developer and INDUSTREX FX Fixer are available in EMEA only. See
CHSP-8994 for more information.
Automatic Processing Chemicals:
? INDUSTREX Single Part Developer Replenisher to make 40 L, CAT 531 5288
? INDUSTREX Single Part Developer Starter to make 19 L, CAT 835 1413
? INDUSTREX LO Fixer and Replenisher to make 40 L, CAT 515 9082
? INDUSTREX DX Developer 2x20 L CAT 550 4923
? INDUSTREX FX Fixer 2x20 L CAT 550 4931
Manual Processing Chemicals:
INDUSTREX Manual Developer Kit to make 40 L, CAT 105 7009: Kit contains two 5 L
bottles of developer, two 1 L bottles of developer and two bottles of stop bath.
INDUSTREX Manual Fixer Kit to make 40 L, CAT 105 7017: Kit contains two 5 L
bottles of fixer, two 1 L bottles of fixer and two bottles of rinse solution.
Sold separately:
? INDUSTREX Manual Developer to make 40 L, CAT 532 0635
? INDUSTREX Manual Fixer to make 40 L, CAT 532 0643
? INDUSTREX Manual Stop Bath to make 40 L, CAT 105 4873
? INDUSTREX Manual Rinse Solution to make 40 L, CAT 105 7025