Visual inspection is an important first step in the particle identification process for pharmaceutical liquids and presentations. It provides an overview of product characteristics and defects that can be connected to particle content. Membrane microscopic counting is a key technique for quantifying particulate matter at various size ranges. Proper isolation, characterization, and identification of particles is essential to determine their origin and ensure product quality and stability.
1 of 36
Downloaded 201 times
More Related Content
Pda Visual Inspection 2009 Aldrich
1. Particulate Matter - Visual Detection to Identification Scott Aldrich PDA Visual Inspection, October 19-20, 2009
2. Concepts Visual inspection is the start of the analytical process for particle identification Inspection-coupled isolation provides the necessary understanding of defect character Inspection allows connection of package defects to particle content
3. Rules for Products Appropriate Design Robust Formulation No Changes Clean Stable
4. Visual Inspection Often unappreciated as a diagnostic tool Vital process for stability evaluation Essential first step in particle identification process Provides high-level overview of product character
5. Tracking Product Physical Stability Why? Primary Verifies Acceptable and Stable Presentation Expedites Development by Revealing Problems Avoids Surprises Secondary Problem-solving defect incidents Investigates all components Why Used How Used Fabrication, Process Stream
6. Visible Sub-visible Sub-micrometer Size Domains 1袖m 25袖m 10袖m 150袖m Increasing Probability of Detection What size domain matters for the product stability? Visible Gray zone
7. Pharma Liquid Products and Presentations A Complex Array PARENTERAL PRODUCTS, AQUEOUS AND NON-AQUEOUS Small Molecule; <1000mw Large Molecule; >1000mw Low Concentration High Concentration Ophthalmic Systems Others Novel Deliveries Sub-Q Systems Gels, Diffusion substrates
8. Pharma Liquid Products and Presentations A Complex Array Package Systems Glass Vial/closure Ampoule Plastic Blow-Fill-Seal Formed sheets Syringes Pre-filled Syringes Devices Delivery (IV) Sets Commercial RTUs Formulations Liquid, aseptic/terminal Lyophilized Solids Suspension, aseptic/terminal Dry-filled sterile powders Emulsions Nano-particle delivery
9. Development Timeline & Distractions Small Scale Crud, ignored Package is Changing Small Batches, Few Containers Used First of many API Processes Clinical Scale Package and Presentation Defined Set? Customer Use Experience Full Scale/Launch Process Improvements Cost and Time-Saving Unanticipated Insoluble/non-volatile Substances Vendor Lost or Changed Ingredient Quality/Character different than in Development
10. Commercial Product Quality Product Form Well-Described Product Use Well-Understood Product Appearance Consistent to the Level of Detection Sensitivity Consensus of Defect Definition Category Identity Effect or Importance Critical Major Minor
11. Compendial Requirements Robust, Safe, Sterile, Pure and Effective USP Chapter <1> Injections USP Chapter <788> Injections/<789> Ophthalmic Products USP/EP/JP have Harmonized <788> PM Testing Pharm. Forum re: Chapter <788>: IM and Sub-Q must meet <788> Pharm. Forum 35[3] May-June 2009, page 628 Radiopharmaceuticals are exempt from <788> limits Parenteral products for which labeling specifies use of a final filter are exempt from <788>, provided scientific data are available to justify the exemption. (do your homework). Irrigating solutions are exempt.
13. Particle Count by Light Obscuration First Tier Groves, 1993 CONSTITUTES KEY FILING DATA
14. Counting by Membrane Assay Second Tier Calibrate Optical Microscope at 100x for 10 m, 25 m Size Domains System Suitability Blank Filter Isolation of Particles from the Liquid Product Oblique and Epi-Illumination Reveals Particles on the Membrane Tabulates Particles in Size Categories, Reveals Nature MOST IMPORTANT IN PRODUCT DEVELOPMENT
15. The ID Process Confirm Isolate Characterize Identify Locate
16. What Constitutes a Defect? Appearance and Evident Changes Color Haze Solids/Particles Container to Container Differences Time of Release Failure Trend over Time 3 Sigma Failure ? Catastrophic Failure
17. Just What is Acceptable? Essentially free Just a few per container? Just a few per batch? After defect removal, the batch is essentially free of foreign and visible particulate matter Inspection result at historical AQL? The Long Range View: Essentially free of visible particulate matter means free of particles that are considered indicative of physical instability of the product or of interaction between the formulation and the container/closure system.and The low incidence of containers with observed extrinsic material have been removed. Identification process should not depend upon definition!
18. Isolation Methods Direct removal, liquids Capillary tube (Wiretrol) Poly tube, drawn to fine tip Membrane swipe Filtration Centrifugation Direct removal, dry materials Tungsten wire, 1-5袖m tip Fine hair Fine scalpel, cleaver (MicroTool) Facilitate with water, or weak known adhesive Transfers, Concentrators Dried KBr Cleaned filter paper Capillary rounds/flats
20. Isolate Whats Seen Evaluation of Isolated Particulate Matter, to Determine: point source environmental formulation/package Locate and Remove Source(s) Manufacturing Verifies Improvement RESULT Design Improvement Manufacturing Improvement
21. Inspect Detect Isolate - Identify Observation in Context with Event Inspection with observers or in duplication Categorization of All Species Package vs. Free Tiny vs. Obvious Audit of Species Microscopy-Spectroscopy Process of Characterization Tracking Source from Character/Identity
23. Microscopy Pathway Collection of Properties Size, Shape, Color, Hardness, Association Ref. Indices, Birefringence, Crystal System Simple Experiments Solubility What extracts, separates? Heating studies Functional Group Tests Feigl, Stahl, Chamot & Mason, Benedetti-Pichler, McCrone et al Comparison to Known Materials Public Database Internal Database Careful examination of components, process
24. Observations via Microscopy Habit Flake Rod Acicular Equant Tablet/Plate Fiber Lath Refractive Index (n) Dispersion of n Degree of Transparency Color Resolution is?
25. Microscopy Tricks of the Trade Maintain visual connection as much as possible Withdrawal from fluids Capillary tubes: Wiretrol Can you see the isolate Can you beam it? Isolation on the package Filtration Sedimentation Location on/in solids Change views often Transmitted Oblique/darkfield Single pol Crossed pols Filters; 村 wave, 1 Red Under stress Pressure Heat Solvent Exposure
26. Microscopy Tricks of the Trade Physical Tests Magnetic attraction Hardness via cover slip: Locards exchange principle put it to work Water exposure what happens upon humidification? Visual Stereomicroscopy Compound Pol Electron microscopy IR Microspectroscopy Photographs are great, but can you draw it? Observations are refined by the need to render accurate drawings .
28. PLM Spectroscopy Hotstage Schemes for Material Ultramicroanalysis (Light Obscuration) Membrane Isolate Picking Direct SEM-EDS Optical Count PLM-Spectroscopy Direct SEM-EDS ID Quant
29. The Nature of Material Association Singular Liquid Solid Combinations Multiple Aggregate/Agglomerate no distinct boundaries (matrix evident?) boundaries? with similar material, foreign material? Groups of groups? Homogeneous heterogeneity? Polycrystalline Microcrystalline Cryptocrystalline Layered Coated Crystallinity None Evident Amorphous Methods Used? Distinct? Or Continuum? Liquid: 2-D order Solid: 3-D order Isometric (1 ri) Uniaxial (2 ri) Tetragonal Hexagonal (trigonal) Biaxial (3 ri) Orthorhombic Monoclinic Triclinic Sub-optimal solid state
30. PARTICULATE MATTER ORIGINS ADDITIVE/EXTRINSIC Single event/Unchanging -environmental -machine -personnel -inadequate prep/cleaning -closure source INTRINSIC/MULTIPLE EVENT GROWTH/INTRINSIC/CHANGING Package Change Leaks Ingredient purity/change Active purity/change Product-Package interaction CHANGE MECHANISMS Coalescence Sedimentation Nucleation Crystallization Hydrate Formation Solvate Formation Polymorphism Salt Formation Degradation Chemical Physical Effects Temperature Shear Light Oxidation Oligomerization Impurities Drug Concentration Effects/Micelles Leaching/Extraction
31. Studying the Occurrence Point Source or General Load? Mfg. Points of Contact Batch Character Product Character Facility Impact Process Effects Next Studies/Directions Analytical Microscopy Partners with Formulation and Manufacturing
33. Membrane Microscopic Count is Key Bio: Scott Aldrich is a long-standing member of American Chemical Society, AAPS, State Microscopical Society of Illinois, PDA and Microscopy Society of America. He is a member of the United States Pharmacopeia (USP) Parenteral Products Industrial Expert Committee for the current (2005-2010) term. He is a 38 year veteran of the pharmaceutical industry, through employment at Upjohn, Pharmacia, and Pfizer. Scott is President of Ultramikro, LLC an independent consulting firm specializing in microscopy training and particulate matter control programs.
35. Whats Visible? It Depends Brewer & Dunning: about 30 m Akers, MJ; Larrimore, DS and Guazzo, DM. Parenteral Quality Control, Drugs and the Pharmaceutical Sciences, vol 125, 3 rd Ed. Marcel Dekker, 2003. Turco & King: near 50 m Turco S and King RE, editors. Sterile Dosage Forms, Chapter 6, Handling and Administration, Young RE. Lea & Febiger, Philadelphia, PA, 1979, pg. 120. Delly: 85-100 m Delly JG. The Microscope, Diffraction Lines Editorial, The Eyes Have It, 1998, Vol. 37, No. 2, pg 195-211 . 70% probability of detecting a single 150 m particle Shabushnig, Melchore, Geiger, Chrai and Gerger, PDA Annual Meeting 1995
36. FDA Review of Recent PM Data 295 Drug Applications (SVPs, by LO)* * Nath, et al. Particulate Contaminants of Intravenous Medication and the Limits set by USP General Chapter <788>, 2005 Pharm. Forum n/a n/a 151 1504 Mean + 3SD 13 (27)/mL 59 (89)/mL 15 (43)/pkg 219 (415)/pkg Mean (賊 1SD) 1983 data (19 LVP products by membrane) ALL 406 lots (354 in glass vials) 10 (24)/pkg 82/pkg 154 (289)/pkg 1021/pkg 17 (45)/pkg 153/pkg 245 (438)/pkg 1560/pkg Mean (賊 1SD) Mean + 3SD 600 25 m 6000 10 m 600 25 m 6000 10 m USP <788> Limits 112 294 # Batches TERMINAL STERILE PROCESS ASEPTIC PROCESS