Use of triaxial accelerometer and data logger to measure hammer induced shock pulses in a metal tube. Calculate attenuation and material damping ratio for use in Solidworks FEA simulation
1 of 7
Download to read offline
More Related Content
Shock damping and attenuation measurement
1. Shock Damping and Attenuation
Desktop Experiments
3/23/2017 rev A
Don Blanchet
3B Associates
dwb3298@verizon.net
2. Tools & Goals
Hammer tap testing shock measurements.
Small hammer repeated blows
3 foot long steel pipe
1.6 inches diameter
.060 inch wall thickness
Free/free support natural frequency ringing
MIDE slam stick model C data logger
Measure acceleration time signal
Process FFT and PSD
Calculate attenuation in decibels end to end
Calculate damping %