Surface temperatures can be a difficult measurement. Special engineering and extensive testing of the Smart Sensor surface pad provides fast response and accurate surface measurement. Model 1500 shown above has been used extensively as the primary control element for freeze protection control loops. A retractable design that allows removal of the sensor while leaving the surface pad in place is also available. Smart sensor designs have be used to measure the skin temperature of vessels, pipes, boiler tubes, superheater tubes or where ever the process requires surface temperature measurement.
1 of 1
Download to read offline
More Related Content
Surface Temperature Sensors and Transmitters for Industrial Applications
1. 息 2014 Smart Sensors an SOR Company 1920 Aldine Western Houston, TX 77038 Phone: 281-272-5333 Fax: 281-272-5332
Specialty Sensors - Surface
Electric Trace Sensor - Type 1500 and 1500R
TYPE 1500 - Used to accurately measure the surface temperature of any pipe or tank
greater than 3 inches in diameter. The standard X and Y dimensions reduces the heat
sinc effect and greatly improves the accuracy. The 1500 is widely used for electric heat
tracing control for freeze protection and process control, especially where changes in
temperature can cause process material to stratify.
Head Type Type Calibration X Junction Y Options
1500 or 1500R (see drawings for standard X and Y dimensions or indicate
To order: Indicate the code letter or value for each requirement.
Head Type
0 No Head
CA Cast Aluminum
CI Cast Iron
CSS Cast Stainless Steel
LCA Large Cast Aluminum
PP Polypropylene (Black)
PPS Polypropylene Sanitary
FTA Flip Top Aluminum
FTP Flip Top Poly (white)
EPA Explosion Proof Aluminum
EPS Explosion Proof Stainless Steel
EHA Explosion Proof Aluminum
EHI Explosion Proof Iron
Calibration
J Iron Constantan速
K Chromel速 Alumel速
T Copper Constantan速
E Chromel速 Constantan速
N Nicrosil速 Nisil速
PO Low Temp RTD to 500属 F
PH High Temp RTD to 900属 F
PM Heavy Duty RTD to 900属 F
Standard RTD is a three-wire 100 ohm Platinum / .00385 Alpha. For higher
temperature ranges - consult factory. For special limits on thermocouples, repeat
calibration code, i.e. JJ.
Sensor Junction
G Grounded
U Ungrounded
DG Dual Grounded
DU Dual Ungrounded
S Single RTD
D Dual RTD
FW Four Wire RTD
OPTIONS
S 3/4 - 2 (specify radius)
M Radius for NPT pipe sizes 3 - 6
L Radius for NPT pipe sizes 6 and above
Type 1500
Type 1500R
Pad
2
2
Pad
TYPE 1500R - This surface temperature design allows easy removal of the sensor. In
applications where there is heavy insulation on the pipe the sensor can be removed
without disturbing or removing the insulation, reducing replacement downtime and
costs.
Type
1500
Type 1500R
is available with
EHA and EHI
heads only
X
(4 Std.)
X
(4 Std.)
Type RTD Type L Junction
(see drawings for standard X and Y dimensions or indicate desired dimension in inches)
To order replacement sensor for Type 1500R:
Indicate the code/value for each requirement.
1500RS
B-1
Type
1500
Type
1500R
Type
1500R
Type
1500
11.50
(L= x + y - 1/2)
1/4 OD
3/8 OD
3 Radius
Y
(3 standard)
Y
(8 standard)
Sensor
Sensor
Type
1500R
8.25 2.001.25
desired dimension in inches)
EPAA Explosion Proof Aluminum Atex
11.5
Alliance Technical Sales | Clarendon Hills, IL |
630-321-9646 | www.alliancets.com