TECHNICAL SERVICES Thermal Facilities Building glazing thermal analysis ¨C relative to facades and glazing U-Value calculations Advice on glass thermal coatings Advice on part L of building regulations related to glazing element 2D Infrared thermal simulation of products 2D Flux magnitude simulation of products Display Isotherms through detail section  Dew point calculation Interstitial condensation assessments
?
?
TECHNICAL SERVICES Day lighting Facilities Building day light analysis ¨C relative to facades and glazing Stereographic diagrams to show sun path Waldram diagrams to show sun path Average daylight calculations for rooms  Advice on glare control glass G-Value calculations Light transmittance values Reflectance values of glazing Advice on near by obstructions relative to glazing ¨C Right to light Solar shading analysis to show shading on window throughout the year
TECHNICAL SERVICES Day lighting Facilities
TECHNICAL SERVICES Day lighting Facilities
TECHNICAL SERVICES Structural Facilities Wind flow around facades Wind flow around roof lights Simple computational fluid dynamics Area wind load to BS6399 for facades Pressure zones across a fa?ade to BS6399 Uplift force for canopy¡¯s and roof lights to BS6399 & BS5516 Calculations for aluminium systems including: Transom calculations Dead loads Design bending moment Bending resistance Design shear force Shear resistance Transom deflection due to dead load  Elastic moment for buckling Wind load checks Design bending moment Bending resistance Design shear force Shear resistance Transom deflection due to wind load Elastic moment for buckling Combined loading Mullion calculations Wind load per span Bending moment Peak shear force Bending resistance Buckling check Shear resistance Deflection check Tensile stress General yielding along the member Local failure at  critical section
TECHNICAL SERVICES Ventilation Facilities Natural ventilation and free air flow through Louvre systems Slot trickle vents Glazed in trickle vents Adjustable Air flow Smoke vents
TECHNICAL SERVICES Testing Site water permeability test carried out to CWCT test method 9 Thermograph of facades before and after Infrared images showing surface temperatures
TECHNICAL SERVICES Standards & Affiliates CDM regulations  British standards Building regulations CWCT standards for systemised building envelope  Seat on board for - Council for Aluminium Building - Technical Committee Member of CAB Member of Centre for window and cladding technology Member Glass & Glazing Federation Member of construction line About to become member of ¡°The green organisation¡± ¨C Green apple award
TECHNICAL SERVICES Accreditations ISO 9001 Management Accreditation ISO 14001 Environmental Accreditation ISO 18001 Health & Safety Accreditation All fitters carry CSCS cards All fitters have CRB checks Chas accreditation

More Related Content

Technical Notes

  • 1. ?
  • 2. ?
  • 3. ?
  • 4. ?
  • 5. TECHNICAL SERVICES Thermal Facilities Building glazing thermal analysis ¨C relative to facades and glazing U-Value calculations Advice on glass thermal coatings Advice on part L of building regulations related to glazing element 2D Infrared thermal simulation of products 2D Flux magnitude simulation of products Display Isotherms through detail section Dew point calculation Interstitial condensation assessments
  • 6. ?
  • 7. ?
  • 8. TECHNICAL SERVICES Day lighting Facilities Building day light analysis ¨C relative to facades and glazing Stereographic diagrams to show sun path Waldram diagrams to show sun path Average daylight calculations for rooms Advice on glare control glass G-Value calculations Light transmittance values Reflectance values of glazing Advice on near by obstructions relative to glazing ¨C Right to light Solar shading analysis to show shading on window throughout the year
  • 9. TECHNICAL SERVICES Day lighting Facilities
  • 10. TECHNICAL SERVICES Day lighting Facilities
  • 11. TECHNICAL SERVICES Structural Facilities Wind flow around facades Wind flow around roof lights Simple computational fluid dynamics Area wind load to BS6399 for facades Pressure zones across a fa?ade to BS6399 Uplift force for canopy¡¯s and roof lights to BS6399 & BS5516 Calculations for aluminium systems including: Transom calculations Dead loads Design bending moment Bending resistance Design shear force Shear resistance Transom deflection due to dead load Elastic moment for buckling Wind load checks Design bending moment Bending resistance Design shear force Shear resistance Transom deflection due to wind load Elastic moment for buckling Combined loading Mullion calculations Wind load per span Bending moment Peak shear force Bending resistance Buckling check Shear resistance Deflection check Tensile stress General yielding along the member Local failure at critical section
  • 12. TECHNICAL SERVICES Ventilation Facilities Natural ventilation and free air flow through Louvre systems Slot trickle vents Glazed in trickle vents Adjustable Air flow Smoke vents
  • 13. TECHNICAL SERVICES Testing Site water permeability test carried out to CWCT test method 9 Thermograph of facades before and after Infrared images showing surface temperatures
  • 14. TECHNICAL SERVICES Standards & Affiliates CDM regulations British standards Building regulations CWCT standards for systemised building envelope Seat on board for - Council for Aluminium Building - Technical Committee Member of CAB Member of Centre for window and cladding technology Member Glass & Glazing Federation Member of construction line About to become member of ¡°The green organisation¡± ¨C Green apple award
  • 15. TECHNICAL SERVICES Accreditations ISO 9001 Management Accreditation ISO 14001 Environmental Accreditation ISO 18001 Health & Safety Accreditation All fitters carry CSCS cards All fitters have CRB checks Chas accreditation