This document summarizes the configuration of a Unity XT 380 storage system with the following specifications:
- It has a total raw capacity of 82.22TB spread across 21 drives including 400GB flash, 600GB SAS, and 12TB NL-SAS drives in a RAID 5+1 and RAID 6+2 configuration for a total usable capacity of 45.62TB.
- The system has a maximum throughput of 19957 IOPS and uses 80% read/20% write workload.
- Additional details provided include power consumption, environmental specifications, I/O configuration using 10GbE, and software suites included.
1 of 4
More Related Content
Unity v1 unity_xt_380
1. Unity v1 Unity XT 380
Index Page
System Cabinet Layout 1
General Information 1
System Tier Information 1
Pool Configuration 2
Power Information 2
I/O Configuration 2
Software Suites 3
Additional Information 3
2. Cabinet 1
General Information
Model Number Unity XT 380
Raw Capacity 82.22 TB
Unit Count 5 U
IOPS 19957
Block Size 8K
Usable Capacity 45.62 TB
Total Drive Count 21
Workload 80% Read - 20% Write
Capacity Utilization NA
Configuration Type New Solution
System Tier Information
Flash Count Spares
400GB FLASH 2 9 1
Total 10
Usable Capacity 2.86 TB
SAS Count Spares
600GB 10K 4 0
4
0.00 TB
NL-SAS Count Spares
12TB 7.2K 6 1
7
42.76 TB
Page 1
3. Pool Configuration
Pool1
Tier Form Factor Drive Type RAID Type Drive Count
Usable
Capacity
IOPS
FLASH 2.5 400GB FLASH 2 RAID 5 (8+1) 9 2.86 TB 19687
NL-SAS 3.5 12TB 7.2K RAID 6 (4+2) 6 42.76 TB 270
Total 15 45.62 TB 19957
Power Information
Power Summary
Power Consumption 0.77 kVA
Region United States
Input Voltage V~208
Phases Single Phase
Site Circuit Breaker 30
Peak Inrush Current 75 A
Environmental
Operating Temp Below 26C
Heat Dissipation 2300 Btu/Hr
Sound Pressure 60 db
Sound Power 7.1 bels
Weight 502 lbs
Dimensions 24 in Width x 39.4 in Depth x
75 in Height
Clearance 42 in Front x 36 in Rear x
18 in Top
Energy Cost
Annual Energy Cost
GHG Emissions 6.6 tonnes/yr
Currency
PUE 2
Emission Factor 1238.39 lb/MWh
Local Utility Rate
I/O Configuration
Onboard CNA 10GbE Opt SFP
Page 2
4. Software Suites
Unity Hybrid Base Software ? Unisphere Suite
? File, Block, VVols
? Snapshots
? Encryption
? Anti-virus
? Native Replication
? FAST Cache & FAST VP
Additional Information
System Drive Tier Performance
System Drives Used For Data No
Raw Percentage of Flash 5 %
Operating System Version Unity 5.0
Date Created 20 Nov 2020
Midrange Sizer Version 8.5.3
Reserved NVMe Slots No
Total Spares 2
Legal Disclaimer
Dell EMC provides Midrange Sizer as a tool to help estimate, size and analyze storage capacity and IOPS requirements for
Unity, SC Series and PowerVault array. Midrange Sizer is provided solely for estimating storage sizing. Results are based on
ordering requirements and best practices of product capabilities and limitations. Midrange Sizer uses a set of sizing assumptions
along with provided inputs which may cause results to vary greatly due to many specific factors such as the environment
setup/infrastructure, use-case and workload.
Midrange Sizer¡¯s output is not a guarantee that a storage array will meet all actual data storage sizing requirements or any
expected savings.
Please carefully read all of the terms of this disclaimer. By viewing and utilizing Midrange Sizer, you acknowledge that you have
read, understand and agree to this disclaimer.
* TB/GB label represents capacity in base-2 i.e. 1TB = 1024*1024*1024*1024 bytes
* True effective capacity and usable capacity are reported which is calculated after all spare space is accounted for.
Page 3